People's Republic of China architectural code and regulatory reference. Covers the GB (Guojia Biaozhun -- National Standard) series of mandatory codes including GB 50352-2019 Civil Buildings Unified Design Standard (replaces 2005), GB 50016-2014 (2018 ed.) Fire Protection Design of Buildings, GB 51251-2017 Smoke Control + Prevention, GB 50045 (legacy high-rise fire), GB 50011-2010 Seismic Design (with 2016 amendments), GB 50009-2012 Building Structural Loads, GB 55015-2021 General Code for Building Energy + Renewable Energy, GB 50189-2015 Public Building Energy Design, JGJ 26-2018 + JGJ 75-2012 + JGJ 134-2010 Residential Energy Design (by climate zone), GB 50763-2012 Code for Design Accessibility, GB 50352 civil building, plus the supplementary JGJ (Industry Standard) codes. Includes the five thermal climate zones per GB 50176-2016 (Severe Cold, Cold, Hot Summer Cold Winter, Hot Summer Warm Winter, Temperate), the eight seismic intensity zones (degree 6-9), the sunlight rights (Rizhao) regulation governing residential setbacks, DB local supplements (DB11 Beijing, DGJ08 Shanghai, DBJ Guangdong + Guangxi etc.), Hong Kong SAR distinct regulation (Buildings Department BD HK BO Cap 123 + PNAPs + ATCs), Macao separately, and the China Sponge City Program, Green Building Label (3-star China Green Building Evaluation Standard), and the Construction Engineering Quality Management Regulations.

Install

npx vskill@latest install amanbh997/skills-architects/country-china

SKILL.md

Country: People's Republic of China

Architectural code and regulatory reference for projects in mainland China. Hong Kong SAR has a distinct regulatory regime briefly summarised at Section 12 (different code system, English language, Common Law tradition). Macao SAR also distinct. Taiwan is not covered here.

Activate this skill on any Chinese city reference (Beijing, Shanghai, Guangzhou, Shenzhen, Chengdu, Chongqing, Hangzhou, Nanjing, Tianjin, Wuhan, Xi'an, Suzhou, etc.), CNY/RMB/Yuan currency, mention of "GB 50016"/"GB 50352"/"GB 50011"/"JGJ"/"DB11"/"DGJ08", or Chinese architectural terminology (容积率 yongji-lv, 建筑密度 jianzhu-midu, 日照 rizhao, 抗震 kangzhen, 防火 fanghuo).


1. Regulatory Hierarchy

China operates as Archetype D (Centralised National + Strong-Form Mandatory Clauses). National GB codes are mandatory throughout the country; local DB supplements may only be more stringent, never less.

1.1 Authority Stack
LEVEL 1 -- NATIONAL
Ministry of Housing and Urban-Rural Development (MOHURD, Zhufang he Chengxiang Jianshe Bu)
-- primary building authority
+ State Administration for Market Regulation (SAMR) -- approves standards
+ Standardization Administration of China (SAC) -- standards body
Ministry of Emergency Management (MEM, Yingji Guanli Bu) -- fire approvals
(transferred from Public Security Fire Department in 2018)
Ministry of Ecology and Environment (MEE)
National Energy Administration (NEA) -- energy policy
Ministry of Industry and Information Technology (MIIT) -- industrial
China Disabled Persons' Federation (Canlianhui) -- accessibility policy
LEVEL 2 -- PROVINCE (sheng) + AUTONOMOUS REGION + MUNICIPALITY DIRECTLY UNDER CENTRAL GOVT
4 Municipalities: Beijing, Shanghai, Tianjin, Chongqing
23 Provinces (Guangdong, Jiangsu, Zhejiang, Shandong, etc.)
5 Autonomous Regions (Guangxi, Tibet, Inner Mongolia, Ningxia, Xinjiang)
2 SARs (Hong Kong, Macao) -- own systems
Each issues:
DB Local Standards (e.g., DB11 Beijing, DGJ08 Shanghai, DBJ Guangxi 45, DB Guangdong 44, DB Zhejiang 33)
Provincial Construction Department (Sheng Jianshe Ting)
Provincial Fire Department (now Yingji Ting)
LEVEL 3 -- PREFECTURE / CITY
Local Construction Bureau (Jianshe Ju)
Planning Bureau (Guihua Ju, now usually merged with Natural Resources Bureau Ziyuan Ju)
Emergency Management Bureau (Yingji Guanli Ju) -- former Fire Department
Land + Resources Bureau (Guotu Ju, now Natural Resources Bureau)
Environmental Protection Bureau (Huanbao Ju)
LEVEL 4 -- DISTRICT / COUNTY
Smaller cities + counties -- delegated authority from prefecture
LEVEL 5 -- PROJECT
Construction Engineering Planning Permit (Jianshe Gongcheng Guihua Xuke Zheng) from Planning
Construction Permit (Shigong Xuke Zheng) from Construction Bureau
Construction-Engineering Quality Supervision (Zhiliang Jiandu) from Construction Quality Office
Fire approval (Xiaofang Shenpi) from Emergency Management Bureau
Inspection by accredited testing institutes
1.2 GB Code Type Classification

Codes are classified by mandatory level:

  • GB Mandatory (Qiangzhi Xing) -- printed in red -- legally binding, must comply; deviation requires special approval
  • GB Recommended (Tuijian Xing) -- printed in black -- advisory; can be followed but not legally binding
  • JGJ Industry Standards -- MOHURD industry standards, generally recommended but commonly adopted
  • DB Local Standards -- provincial/municipal; may only be more stringent than national GB
  • DBJ -- Local Building Standards (subset)

A single project must comply with the strictest applicable provision across these layers.

1.3 Construction Drawing Review (Shigong Tu Shencha)

Distinct Chinese process: before construction can begin, all construction drawings must be reviewed by an accredited Construction Drawing Review Institute (Shigong Tu Shencha Jigou) -- private body certified by provincial government. They check compliance with all applicable GB/DB codes. Review takes typically 15-30 days, longer for complex projects.


2. Building Code Core Requirements

2.1 GB 50352-2019 Civil Buildings Unified Design Standard

The "constitution" of Chinese building design. Replaces 2005 version. Defines:

  • Civil Building (Minyong Jianzhu) Classification:
  • Residential (Juzhu Jianzhu)
  • Public Building (Gonggong Jianzhu) -- offices, commercial, hotels, hospitals, schools, etc.
  • Building Heights:
  • Low-rise residential: 1-3 storeys
  • Multi-storey residential: 4-6 storeys
  • Mid-rise residential: 7-9 storeys
  • High-rise residential: ≥10 storeys OR ≥28 m
  • High-rise public building: > 24 m
  • Super-high-rise: > 100 m
2.2 GB 50352 General Provisions
  • Floor-to-floor height: residential 2.8-3.0 m; office 3.6-4.5 m; hospital 4.0-4.5 m; commercial 4.5+ m
  • Net ceiling height (Jingkong Gao): residential 2.4 m min; corridor 2.1 m min
  • Stair: width 1.10 m residential, 1.20 m public; max riser 0.18 m, min going 0.26 m
  • Door clear width: 800 mm general, 1000 mm main entrance public
  • Setback to road red line: per municipal Detailed Regulation Plan
  • Setback to property line: per municipal regulation; typically 3-12 m
2.3 Yongji-lv (容积率) -- FAR Equivalent
  • Yongji-lv = total above-grade GFA / lot area
  • Jianzhu Midu (建筑密度) = building footprint / lot area (similar to coverage)
  • Both controlled by Konngzhi Xing Xiangxi Guihua (Detailed Regulation Plan) for each plot
  • Typical residential yongji-lv: 1.0-3.5; commercial 4.0-8.0; CBD towers higher
2.4 Sunlight Rights (Rizhao Quan, 日照权)

Distinctive Chinese regulation: every residential dwelling must receive a specified number of hours of unobstructed sunlight on the worst day of winter (大寒 Da Han, around 20 January), measured at the lowest occupied window. Targets:

Climate ZoneRequired Sunlight Hours (mid-winter Da Han)
Severe Cold (Zone I)≥3 h
Cold (Zone II)≥3 h
Hot Summer Cold Winter (Zone III)≥2 h
Hot Summer Warm Winter (Zone IV)≥1 h or local rule
Temperate (Zone V)≥2 h

This drives Chinese urban form: long parallel slab blocks (north-south or oriented), substantial spacing between blocks, distinct from Western tower-on-podium. Calculation per GB 50180-2018 + local rules.

2.5 Setbacks Between Buildings (Jianzhu Jianju, 建筑间距)
  • For residential blocks, minimum distance between facing facades = function(building height + use + sunlight ratio).
  • Common rule of thumb: distance = 1.0 - 1.3 × north building height in Cold zone (more for higher latitude)
  • Local DB specifies exact formula
2.6 Height & Use Classification (GB 50352 + GB 50016)
Building HeightClassificationImplications
< 24 m (≤ 10 storey roughly)Low/Multi-storeyStandard rules
24-100 mHigh-rise (Gao Ceng)GB 50016 high-rise rules; sprinklered above 27 m residential or 24 m public
> 100 mSuper-High-Rise (Chao Gao Ceng)Additional rules; structural performance review
> 250 mSuper-TallSpecial structural performance review by national experts

3. Fire Safety (GB 50016 + GB 51251)

3.1 GB 50016-2014 (2018 Edition) -- "Code for Fire Protection Design of Buildings"

The single most-cited code on Chinese projects. Major 2018 amendment post the SCMP-reported high-rise fires. Replaces older legacy codes including GB 50045-95 (high-rise specific).

Structure:

  • Ch. 1 General
  • Ch. 2 Terminology
  • Ch. 3 Production + Storage Buildings (industrial)
  • Ch. 4 Hazardous Materials Storage + Use
  • Ch. 5 Civil Buildings -- the most-used chapter; fire-resistance, compartmentation, egress for all civil buildings
  • Ch. 6 Building Construction (combustibility, materials)
  • Ch. 7 Building Equipment
  • Ch. 8 Active Fire Protection Systems
  • Ch. 9 Heating, Ventilation, Air Conditioning
  • Ch. 10 Electrical
  • Ch. 11 Wood-Frame Buildings
  • Ch. 12 Existing Buildings
  • Annexes A-F
3.2 Civil Building Classification by Fire Hazard (GB 50016 Ch. 5)
CategoryExamples
Class I High-Rise (Yiji Gao Ceng)Hospitals, broadcasting + telecom centres (over 50 m), >100 m public, large train station, conference, exhibition
Class II High-Rise (Erji Gao Ceng)Most office, hotel, commercial high-rise; >50 m residential; >24 m public general
High-Rise ResidentialAll residential ≥ 27 m -- with special sub-categories at 54 m, 100 m, 200 m thresholds
Multi-StoreyBuildings < 24 m public OR < 27 m residential
3.3 Fire-Resistance Class (Naohuo Dengji)
ClassDescription
First Class (Yiji)Non-combustible structural members; 3 h frame; 1.5 h floors
Second Class (Erji)Non-combustible; 2.5 h frame; 1 h floors
Third Class (Sanji)Mixed; 2 h frame
Fourth Class (Siji)Combustible structure tolerated; 0.5 h frame

High-rise (Class I + II) must be at least First Class. Residential mid-rise often Second Class.

3.4 Egress (GB 50016-2014 Ch. 5)
ParameterValue
Max travel distance (residential >9 storey)40 m (sprinklered); 25 m unsprinklered
Max travel distance (office sprinklered)40 m one-direction; 80 m two-direction
Max travel distance (hospital sprinklered)30 m
Max travel distance (assembly sprinklered)30 m
Min corridor width residential1.2 m (mid-rise); 1.4 m (high-rise)
Min corridor width office mid-rise1.4 m
Min stair width residential1.1 m
Min stair width public mid-rise1.2 m
Min stair width public high-rise1.4 m
Min door clear width0.90 m residential, 1.0 m public
Max compartment area residential (Class I high-rise)1500 m2 per floor sprinklered
Max compartment area public Class I (sprinklered)2500 m2 (per fire-resistant compartment)
3.5 Sprinklers (GB 50084-2017)
  • Mandatory for high-rise residential ≥ 54 m (or 100 m per latest amendment)
  • Mandatory for high-rise public buildings ≥ 24 m
  • Mandatory for hospitals, hotels, schools above certain scales
  • Mandatory for underground spaces
3.6 Smoke Control (GB 51251-2017)

Dedicated code for smoke control + smoke prevention. Required for:

  • Atriums
  • Underground spaces
  • Long corridors > 20 m without natural ventilation
  • All compartment areas > 100 m2 without natural ventilation

Specifies mechanical extract rates, makeup air, pressurization, smoke barriers, dampers.

3.7 External Cladding (GB 50016-2014 Section 5.5)

Post-2010s fires (multiple in Shanghai, Urumqi, Shenyang):

  • High-rise residential ≥ 50 m: cladding must be Class A non-combustible (GB 8624-2012)
  • High-rise public buildings: same
  • Non-high-rise but ≥ 24 m: Class B1 acceptable but increasingly Class A preferred
  • Insulation behind cladding: separate fire-rating; Class A non-combustible required in most high-rise
3.8 Refuge Floors (Bi Nan Ceng)

For super-high-rise:

  • Public buildings > 100 m: refuge floor every 15 storeys (or 50 m vertical interval)
  • Residential > 100 m: refuge floor every 15 storeys
  • Refuge floor: not used for occupancy; sized for evacuation capacity; ventilated to outside; protected fire doors

4. Energy Code

4.1 GB 55015-2021 -- General Code for Building Energy + Renewable Energy

Highest-level energy code, replacing fragments of older codes. Applies to all civil buildings nationally. Co-exists with detailed prescriptive codes below.

4.2 GB 50189-2015 -- Public Buildings Energy Conservation

Detailed prescriptive code for offices, hotels, hospitals, large commercial. Sets envelope U-values + HVAC efficiency + lighting power density by climate zone.

4.3 Residential Energy by Zone

This is the start of the file. Read the full SKILL.md on GitHub.

Security

  • Security scanPassed, 100 of 100Pattern checks on the skill's files.
  • Model reviewNot runA model review is scheduled for the next rescan.

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

Repository stars
205
Repository forks
43
7-day trend score
27

Stars and forks are for the whole GitHub repository, not this skill alone. Not refreshed yet.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/amanbh997/skills-architects/country-china/badge)](https://verified-skill.com/skills/amanbh997/skills-architects/country-china)

Something wrong with this skill or its page? Tell us.