Japan architectural code and regulatory reference. Covers the Building Standards Act (Kenchiku Kijun Ho, 1950, fundamentally revised 1998 toward performance-based regulation and 2007 strengthening post-Aneha incident), Building Standards Law Enforcement Order (Kenchiku Kijun Ho Shiko Rei) and MLIT Notifications (Kokuji); the parallel Fire Service Act and Fire Service Law Enforcement Order administered by Fire Department (Shobosho); Energy Conservation Act 1979 superseded by Act on the Improvement of Energy Consumption Performance of Buildings (Kenchikubutsu Sho-Energy Ho) 2015 + amendment 2022; Heart Building Law 2006 (Barrier-Free Law) and JIS S 0026 accessibility standards; City Planning Act with 12 use districts and ratio-based regulation (Yoseki-ritsu volumetric, Kenpei-ritsu coverage, daylighting + setback ratios); the unique two-level seismic design philosophy (Level 1 475-year + Level 2 2475-year), 1981 New Seismic Standard (Shintaishin), Energy Absorption Member design + base isolation + damper systems; AIJ Recommendations for Loads on Buildings 2015; CASBEE (Comprehensive Assessment System for Built Environment Efficiency); BCJ (Building Center of Japan) structural performance evaluation; Architect Law and Class 1/2/ Mokuzo (timber) architect designations; Land + Building Lease Act; and the prefecture + Designated City (Seirei Shitei Toshi) + Core City (Chukaku Shi) administrative tiers.

Install

npx vskill@latest install amanbh997/skills-architects/country-japan

SKILL.md

Country: Japan

Architectural code and regulatory reference for projects in Japan (all 47 prefectures + Tokyo Metropolis). Activate this skill on any Japanese city/prefecture reference, JPY currency, mention of "Kenchiku Kijun Ho"/"BSL"/"Sho-Energy Ho"/"CASBEE"/"AIJ"/"BCJ"/"Shintaishin", or Japanese architectural terminology (yoseki-ritsu, kenpei-ritsu, kakunin-shinsei, kanseikensa, joryoku-do, koshou-tatemono, mokuzo).


1. Regulatory Hierarchy

Japan operates as Archetype D (Centralised National + Strong-Form Clauses). Building regulation is national, administered through prefectures + designated cities under Building Standards Act delegated authority. Some matters are devolved to designated cities.

1.1 Authority Stack
LEVEL 1 -- NATIONAL
Ministry of Land, Infrastructure, Transport and Tourism (MLIT, Kokudo Kotsu Sho)
Housing Bureau (Jutaku Kyoku) -- residential policy
City Bureau (Toshi Kyoku) -- urban planning
Land and Real Estate Industry Bureau
+ issues MLIT Notifications (Kokuji) -- detailed technical requirements
Ministry of Internal Affairs and Communications (Somu Sho) -- Fire Service Agency
Ministry of Health, Labour and Welfare (Kosei Rodo Sho) -- hospital regulations
Ministry of Economy, Trade and Industry (METI, Keizai Sangyo Sho) -- energy + product safety
Ministry of the Environment (Kankyo Sho) -- environmental
Ministry of Education (MEXT) -- school facilities
National Police Agency -- some safety regulations
LEVEL 2 -- PREFECTURE (todofuken) + DESIGNATED CITIES
47 prefectures + 20 Designated Cities (Seirei Shitei Toshi) -- e.g.,
Tokyo (special category as Metropolis), Osaka, Yokohama, Nagoya, Sapporo, Kobe,
Kyoto, Fukuoka, Hiroshima, Sendai, Kawasaki, Saitama, Chiba, Niigata, Hamamatsu,
Sakai, Shizuoka, Okayama, Sagamihara, Kumamoto
Tokutei Gyousei Cho (Designated Administrative Officer) -- typically prefectural or
designated-city housing department; oversees Kakunin-shinsei (building confirmation)
Building Examiners (Kenchiku Shujikan) -- public officials
Designated Confirmation Inspection Agencies (Shitei Kakunin Kensa Kikan) -- private
since 1998 reform; competitive choice
LEVEL 3 -- MUNICIPALITY (shi-cho-son)
Smaller cities, towns, villages -- if not Designated City, defer to prefecture for building
confirmation but handle planning under City Planning Act
Local Fire Departments (Shobosho)
LEVEL 4 -- PROJECT
Kakunin-shinsei (Building Confirmation Application) submitted by Class 1 Architect or
qualified delegate
Structural calculations checked: (a) self-check up to threshold (BCJ-evaluated etc.),
(b) Performance Evaluation by accredited body (BCJ, Japan Engineering Standards
Foundation, etc.) for taller/special buildings
Periodic inspection during construction (Kanseikensa)
Article 7 Inspection (kansei kensa) -- final inspection before occupancy
1.2 Building Standards Act Structure

The Building Standards Act 1950 (BSA) was fundamentally reformed in 1998 (introducing performance-based regulation) and amended again in 2007 (post-Aneha falsified structural calculations scandal, which strengthened independent structural review).

Structure:

  • BSA itself (Kenchiku Kijun Ho) -- legislative framework
  • BSL Enforcement Order (Kenchiku Kijun Ho Shiko Rei) -- Cabinet Order with detailed implementing regulations
  • BSL Enforcement Regulations (Kenchiku Kijun Ho Shiko Kisoku) -- Ministerial Order on procedure
  • MLIT Notifications (Kokuji) -- detailed technical specifications (hundreds)
  • JIS Standards (Japanese Industrial Standards) -- material + product specifications
1.3 Tokyo Special Status

Tokyo Metropolitan Government (Tokyo-to) has 23 special wards (Tokubetsu-ku) functioning as municipalities + the multi-city Tama region. Building confirmation in Tokyo's 23 wards is generally handled by the Tokyo Metropolitan Government Bureau of Urban Development + ward offices for smaller works. Tokyo has its own Tokyo Metropolitan Ordinance on Building Standards -- supplements BSA.


2. Building Standards Act Core Requirements

2.1 Building Classification (Yoto Bunkenchiku)

BSA classifies buildings by use + structure + scale:

Use CategoryDescription
Tokushu KenchikubutsuSpecial Buildings -- assembly, hospital, school, hotel, etc.; many require BCJ structural eval, additional fire requirements
Ippan KenchikubutsuGeneral Buildings -- offices, factories

Special structures (high-rise, large span, special concrete) require BCJ structural performance evaluation per BSA Article 20 + sub-clauses.

2.2 Yoseki-ritsu + Kenpei-ritsu (Volume Ratio + Coverage)

The two principal Japanese density controls:

  • Yoseki-ritsu (容積率, FAR) -- total above-grade GFA / lot area; values 50-1300% by use district
  • Kenpei-ritsu (建蔽率, BCR/Building Coverage Ratio) -- footprint / lot area; values 30-80% by use district
2.3 Use Districts (City Planning Act -- 13 categories)
Use DistrictYoseki-ritsu RangeKenpei-ritsu RangeUse
First Class Low-rise Residential (Daiichi-shu Tei-so Jukyo)50-200%30-60%Houses ≤10/12 m height
Second Class Low-rise Residential50-200%30-60%Similar +small shop
First Class Mid/High-rise Residential100-500%30-60%Apartments + small commerce
Second Class Mid/High-rise Residential100-500%30-60%+ medium retail
First Class Residential100-500%50-80%Residential + offices/retail moderate
Second Class Residential100-500%50-80%+ entertainment limited
Quasi-Residential100-500%50-80%Roads + residential mix
Neighbourhood Commercial200-500%60-80%Shops + service
Commercial200-1300%80%Full commerce + tall buildings
Quasi-Industrial100-500%50-80%Light industrial
Industrial100-400%50-60%Factory mix
Exclusively Industrial100-400%30-60%Heavy industry only
Field of Tanada(rural special)--Agricultural
2.4 Sun-Right + Sky-Right + Daylighting (Hisho-mado Jisshin)

A particularly Japanese set of regulations:

  • Daylighting setback (Nichi-sho ki-zen) -- buildings must allow specified hours of sun (3-5 hours mid-winter) to reach adjacent properties; codified per area; varies by use district
  • Sky exposure plane / road-set-back-ratio plane (Doro Shasen Seigen) -- imaginary inclined plane from far edge of road; building cannot project beyond
  • Adjacent-property setback plane (Rinchi Shasen Seigen) -- imaginary plane from neighbor's lot line
  • Northern exposure setback (Hokugawa Shasen) -- protects northern neighbours from overshadowing
  • Absolute height limit in low-rise residential -- 10 m or 12 m

These controls collectively shape Japanese urban form -- often producing characteristic "stepped" or "wedding cake" massing.

2.5 Structural Articles 20 + Bekkihyo (Annexes)

BSA Article 20 sets four tiers of structural review:

  • Tier 4 (lightest) -- low buildings; sample-rule check
  • Tier 3 -- moderate; specific structural calculation
  • Tier 2 -- high-rise or special; advanced calc + BCJ-evaluated
  • Tier 1 (heaviest) -- super-high-rise or special structural performance; BCJ Performance Evaluation + MLIT Minister Approval required

Tier 1 cases: building > 60 m, or special types (seismic isolation building, special structural performance like FRPs, ultra-light long-span etc.)

2.6 Travel Distance + Egress (BSA + Enforcement Order Article 120-122)
ParameterSprinkleredUnsprinklered
Max travel distance (general)50 m30 m
Max travel distance (assembly, dormitory)40 m30 m
Max travel distance (hospital, ROS-protected)50 m30 m
Min corridor width (Special Buildings >= 200 m2/floor)1.6 m double-loaded; 1.2 m single--
Min corridor width (residential each floor)1.2 m double-loaded; 0.9 m single--
Min stair width (Special Buildings >= 200 m2/floor)1.4 m1.4 m
Min stair width (residential >= 600 m2 total)1.2 m1.2 m
Min door clear width800 mm (Special Buildings); 750 mm (general)--
2.7 Two Means of Escape

Two means of escape required when:

  • Special Buildings any storey > 100 m2
  • Mid-rise Residential > 5 storeys (or > 500 m2 floor)
  • High-rise > certain thresholds

3. Seismic Design

3.1 Two-Level Seismic Design

The defining feature of Japanese structural design. Building must be safe under:

  • Level 1 (Damage Limit) -- frequent earthquakes (~50-year return) -- building remains undamaged, structurally elastic. Design seismic shear coefficient C0 = 0.2 (multiplier on weight).
  • Level 2 (Life Safety / Ultimate) -- rare earthquakes (~475-year return, possibly 2475-year for important structures) -- building may sustain damage but no collapse. Design shear coefficient C0 = 1.0.

The 1981 revision (Shintaishin -- "New Earthquake-Resistance Standard") introduced this two-level approach. Buildings built before 1981 are designated "Kyu-taishin" and many have been retrofitted.

3.2 Building Classifications
  • General buildings: design per Level 1 + Level 2 capacity
  • Important buildings (hospitals, communications, government, large assembly): design factor higher (~1.5×)
  • Hi-rise buildings (> 60 m): site-specific seismic motion + dynamic analysis + BCJ performance evaluation
  • Base-isolated (Menshin) buildings: separate design route + BCJ evaluation
  • Damper (Seishin) buildings: separate design route
3.3 Site Classification + Seismic Coefficients

Japan ground classes (BSA Enforcement Order Article 88):

  • Class 1 (Type 1 ground -- rocky, strong) -- C0 multiplier baseline
  • Class 2 -- alluvial, moderate
  • Class 3 -- soft (e.g., Tokyo Bay landfill) -- highest C0 multiplier
3.4 Standards + References
  • Building Standards Act + Enforcement Order Articles 81-87 + 88
  • AIJ Recommendations for Loads on Buildings 2015 -- Architectural Institute of Japan
  • AIJ Design Standards for Reinforced Concrete Structures (RC), Steel Structures (S), Composite (SRC)
  • JSCE standards -- mainly bridges/civil
  • BCJ Performance Evaluation -- for taller buildings

4. Fire Safety (Fire Service Act + BSA)

4.1 Two Statute System

Japan uniquely operates fire safety under two statutes:

  • Building Standards Act -- "preventive fire-resistance" (Yobo Bosai) -- structural compartmentation, fire-resistance, smoke control DESIGN
  • Fire Service Act (Shobo Ho) -- "active fire fighting" (Soshou Bosai) -- sprinkler, detection, hose reel, evacuation equipment, fire-fighting

Plans must be approved by both Designated Administrative Officer (BSA) and Fire Department (FSA).

4.2 BSA Fire Provisions
  • Fire-resistant building (Taika Kenchikubutsu) -- non-combustible structure, fire-resistance rating per height + use
  • Semi-fire-resistant (Junitaika) -- intermediate
  • Combustible (Mokuzo + similar) -- limited heights + areas, primarily low-rise residential

Fire-resistance hours:

  • Major structural members up to 4 storeys: 1 hour
  • 5-14 storeys: 2 hours
  • 15+ storeys: 3 hours
4.3 Fire Service Act Provisions
  • Sprinklers required: high-rise above 11 storeys, large floors (>700 m2 special), large theatre, hospital >5 storey etc.
  • Automatic fire alarms -- per occupancy type + size
  • Indoor fire hose + Hose reel -- per area
  • Smoke-removal equipment -- per Article 126 BSA Enforcement Order
  • Emergency power -- 30 minutes minimum, sometimes 60
4.4 Stair Smoke Protection

Japan emphasizes outside-air stair (To-no-zen Kaidan) -- stairs vented to outside, often via open balcony. Provides smoke-free escape route without requiring positive pressurization.

This is the start of the file. Read the full SKILL.md on GitHub.

Security

  • Security scanPassed, 95 of 100Pattern checks on the skill's files.
  • Model reviewPassed

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

Repository stars
205
Repository forks
43
7-day trend score
27

Stars and forks are for the whole GitHub repository, not this skill alone. Not refreshed yet.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/amanbh997/skills-architects/country-japan/badge)](https://verified-skill.com/skills/amanbh997/skills-architects/country-japan)

Something wrong with this skill or its page? Tell us.