Spatial Planning
Section 1: Floor Plan Archetypes
The floor plan archetype determines nearly every downstream design decision — structural grid, facade rhythm, servicing strategy, daylight penetration, and occupant experience. The ten canonical plan types below cover the full spectrum of building configurations from narrow residential slabs to deep-plan commercial towers.
1.1 Single-Loaded Corridor
Diagram description: A linear building with habitable rooms on one side only and an open corridor or gallery on the other, typically facing a courtyard or exterior view.
- Typical plan depth: 6–9 m from corridor wall to exterior facade
- Structural grid: 6–8 m bays perpendicular to corridor, 3–4 m bays parallel
- Daylight characteristics: Excellent — all rooms have direct exterior exposure on at least one side; corridor receives borrowed light or is open-air
- Circulation efficiency: Low — corridor serves rooms on one side only, yielding high circulation-to-usable area ratio (NTG penalty 5–10%)
- Best-fit building types: Tropical housing, student residences, hospital wards, hotels in warm climates, gallery-access social housing
- Exemplar buildings: Robin Hood Gardens (Alison & Peter Smithson, London, 1972); Park Hill (Jack Lynn & Ivor Smith, Sheffield, 1961)
1.2 Double-Loaded Corridor
Diagram description: A linear building with habitable rooms on both sides of a central corridor, creating a deeper floor plate.
- Typical plan depth: 12–18 m total (two 6–9 m room depths flanking a 1.5–2.4 m corridor)
- Structural grid: 6–8 m bays perpendicular, 3–5 m parallel
- Daylight characteristics: Good in rooms; corridor is typically windowless and requires artificial lighting or periodic breaks with glazing
- Circulation efficiency: High — corridor serves rooms on both sides, achieving 78–85% NTG in residential, 80–87% in hotel
- Best-fit building types: Hotels, residential apartments, dormitories, hospital departments, budget office buildings
- Exemplar buildings: Unite d'Habitation (Le Corbusier, Marseille, 1952); Trellick Tower (Erno Goldfinger, London, 1972)
1.3 Central Core
Diagram description: A floor plate organized around a central vertical core containing stairs, elevators, risers, and often toilets, with usable space radiating outward to the perimeter facade.
- Typical plan depth: 9–15 m from core face to facade (18–30 m total floor plate dimension)
- Structural grid: 9 m x 9 m or 10.8 m x 10.8 m typical for office; 8.4 m x 8.4 m for residential
- Daylight characteristics: Good at perimeter (within 6–8 m of facade); deep zones beyond 8 m require artificial lighting; core zone is dark
- Circulation efficiency: Excellent — shortest average travel distances, compact service distribution. NTG 75–82% for office
- Best-fit building types: Office towers, mixed-use high-rises, commercial buildings over 10 storeys
- Exemplar buildings: Seagram Building (Mies van der Rohe, New York, 1958); Swiss Re (Foster + Partners, London, 2004)
1.4 Side Core
Diagram description: The vertical core is positioned at one end or one side of the floor plate, freeing the remainder for uninterrupted usable space with maximum facade access.
- Typical plan depth: 12–18 m from core to far facade
- Structural grid: 9–12 m clear spans common to maximize open floor plate
- Daylight characteristics: Excellent — core does not obstruct perimeter daylight; deep floor plates still need supplementary lighting beyond 8 m from facade
- Circulation efficiency: Good — slightly longer travel distances than central core; single direction of egress requires careful code compliance (max 45 m travel distance IBC sprinklered)
- Best-fit building types: Speculative offices (lettable floor plates), creative workspaces, laboratories, buildings on narrow urban sites
- Exemplar buildings: Lever House (SOM, New York, 1952); One Angel Court (Fletcher Priest, London, 2017)
1.5 Point Tower
Diagram description: A compact, typically square or circular floor plate with a central or offset core, rising as a slender tower. Small floor plates (400–800 m²) with high perimeter-to-area ratio.
- Typical plan depth: 6–10 m from core to facade
- Structural grid: Radial or 6–8 m orthogonal grid
- Daylight characteristics: Excellent — high perimeter-to-floor-area ratio ensures most space is within 6 m of facade
- Circulation efficiency: Very high — compact core serves 4–8 units per floor in residential, or open-plan office. NTG 75–82% residential
- Best-fit building types: Residential towers, boutique office towers, landmark/iconic structures, slender urban infill
- Exemplar buildings: Barbican Tower (Chamberlin Powell & Bon, London, 1976); Aqua Tower (Studio Gang, Chicago, 2009)
1.6 Courtyard Plan
Diagram description: Building mass encloses or partially encloses a central open courtyard, creating inward-facing as well as outward-facing rooms.
- Typical plan depth: 6–12 m building depth around 15–40 m courtyard dimension
- Structural grid: 6–8 m bays; loadbearing masonry or frame
- Daylight characteristics: Very good — dual-aspect units possible; courtyard provides sheltered daylight source. Courtyard must be min 1:1 width-to-height ratio for adequate light at lower floors
- Circulation efficiency: Moderate — circulation wraps around courtyard, adding length but creating social/amenity corridor
- Best-fit building types: Low-to-mid-rise housing (3–8 storeys), institutional (schools, monasteries, museums), hotels, mixed-use urban blocks
- Exemplar buildings: Palazzo Farnese (Antonio da Sangallo/Michelangelo, Rome, 1534); Beurret & de la Croix housing (Valerio Olgiati, 2014)
1.7 Atrium Plan
Diagram description: A large internal void (atrium) rises through multiple storeys, with occupied floors opening onto galleries or balconies surrounding the void. The atrium is typically top-lit or side-lit.
- Typical plan depth: 6–12 m from atrium edge to exterior facade; atrium 10–30 m wide
- Structural grid: Long-span (12–15 m) to clear atrium void; 6–9 m in occupied wings
- Daylight characteristics: Excellent at upper levels; diminishes at lower floors of deep atria. Atrium acts as light well. Glazed roof or clerestory essential
- Circulation efficiency: Good — atrium acts as orientation device and social condenser; galleries double as circulation and informal meeting space
- Best-fit building types: Corporate headquarters, shopping malls, hospitals, museums, civic buildings, hotels
- Exemplar buildings: Bradbury Building (George Wyman, Los Angeles, 1893); Commerzbank Tower (Foster + Partners, Frankfurt, 1997)
1.8 Free Plan
Diagram description: Structural columns are set back from the facade on a regular grid, with non-loadbearing partitions freely arranged on each floor independently. The floor plan has no fixed interior walls tied to structure.
- Typical plan depth: Variable — 12–20 m common
- Structural grid: Regular grid (Dom-ino: 5 m x 5 m); pilotis or columns at ground; flat slabs
- Daylight characteristics: Dependent on floor plate depth and window placement; facade is free from structural constraint enabling floor-to-ceiling glazing
- Circulation efficiency: High — absence of loadbearing walls allows optimized corridor placement per floor
- Best-fit building types: Modernist villas, flexible office space, galleries, retail, adaptable-use buildings
- Exemplar buildings: Villa Savoye (Le Corbusier, Poissy, 1931); Farnsworth House (Mies van der Rohe, Plano, 1951)
1.9 Open Plan
Diagram description: A large, unpartitioned floor plate with minimal internal walls or divisions, typically with perimeter structure or long-span trusses enabling column-free interiors.
- Typical plan depth: 18–30 m or more; limited only by daylighting (8 m effective daylit zone from each facade)
- Structural grid: Long-span: 12–18 m (steel) or 9–12 m (concrete). Post-tensioned slabs common
- Daylight characteristics: Moderate — perimeter zones well-lit, deep core zones require artificial light. Atriums or lightwells mitigate this
- Circulation efficiency: Very high — minimal dedicated corridor space; NTG 82–88% achievable
- Best-fit building types: Trading floors, tech offices, co-working spaces, warehouses, exhibition halls, large retail
- Exemplar buildings: Willis Faber & Dumas (Foster + Partners, Ipswich, 1975); Centraal Beheer (Herman Hertzberger, Apeldoorn, 1972)
1.10 Hybrid Plan
Diagram description: Combines two or more plan archetypes within a single floor plate or building — for example, a central core office tower with an atrium zone and a double-loaded residential wing.
- Typical plan depth: Variable — responds to mixed program
- Structural grid: Transitional grids at junctions; transfer structures where grid changes
- Daylight characteristics: Varies by zone — each archetype zone retains its own daylight characteristics
- Circulation efficiency: Moderate — junctions between plan types create circulation complexity; careful wayfinding needed
- Best-fit building types: Mixed-use developments, large civic buildings, university buildings, transport hubs, hospital complexes
- Exemplar buildings: Linked Hybrid (Steven Holl, Beijing, 2009); De Rotterdam (OMA, Rotterdam, 2013)
Section 2: Circulation Design
Circulation consumes 15–30% of gross floor area depending on building type. Efficient circulation design directly impacts NTG ratio, user experience, code compliance, and emergency egress.
2.1 Primary Circulation
Lobbies:
- Main entrance lobbies: min 3.0 m clear height, typically 4.5–6.0 m for commercial
- Lobby area: 0.5–1.0 m² per person served in peak 5-minute arrival period
- Elevator lobbies: min 1.5 m depth in front of elevator doors; 2.4 m preferred for office towers
- Residential entrance lobbies: min 6 m² (BS 9991), concierge desk adds 4–6 m²
Corridors: Minimum corridor widths by building type and code:
| Building Type | IBC Minimum | BS 9999 Minimum | Recommended | |
|---|---|---|---|---|
| Office | 1118 mm (44 in) | 1050 mm | 1500–1800 mm | |
| Residential (common) | 1118 mm (44 in) | 1050 mm | 1200–1500 mm | |
| Hospital | 2438 mm (96 in) | 2100 mm | 2400–3000 mm | |
| School | 1829 mm (72 in) | 1600 mm | 1800–2400 mm | |
| Hotel | 1118 mm (44 in) | 1050 mm | 1350–1500 mm | |
| Retail | 1118 mm (44 in) | 1200 mm | 1800–3000 mm | |
| Assembly | 1118 mm (44 in) | 1200 mm | 2400+ mm |
Dead-end corridors (IBC 1020.4):
- Unsprinklered: max 6.1 m (20 ft)
- Sprinklered: max 15.2 m (50 ft)
- Group I-3 (detention): 15.2 m max regardless
- Exception: single-exit dwelling units per IBC 1006.3.4
Travel distance limits (IBC Table 1017.2):
- Unsprinklered: 60 m (200 ft) for most occupancies; 23 m (75 ft) for H-1/H-2 hazardous
- Sprinklered: 76 m (250 ft) for most; 30 m (100 ft) for H-1/H-2
- Common path of egress: 23 m unsprinklered / 23 m sprinklered for most; 30 m for B/F/S/U occupancies (sprinklered)
2.2 Stair Design
IBC Requirements (Chapter 10):
- Minimum width: 1118 mm (44 in) for occupant load >50; 914 mm (36 in) for ≤50
- Riser height: min 102 mm (4 in), max 178 mm (7 in)
- Tread depth: min 279 mm (11 in)
- Riser-tread relationship: 2R + T = 600–640 mm (optimum 630 mm)
- Uniform risers within a flight: max 9.5 mm (3/8 in) variation
- Maximum flight height without landing: 3.66 m (12 ft)
- Landing depth: min equal to stair width, need not exceed 1220 mm (48 in)
- Headroom: min 2032 mm (80 in) measured vertically from nosing
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/spatial-planning/SKILL.md
Popularity
- Repository stars
- 158
- Repository forks
- 31
- 7-day trend score
- 25
Stars and forks are for the whole GitHub repository, not this skill alone. Refreshed 28 Apr 2026, 6 months ago.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/amanbh997/skills-architects/spatial-planning)