Spatial planning for buildings: floor plan layout and archetypes, circulation design (corridors, stairs, elevators, escalators), core design and vertical service distribution, vertical stacking strategy, net-to-gross optimization, space efficiency metrics, wayfinding, and spatial legibility.

Install

npx vskill@latest install amanbh997/skills-architects/spatial-planning

SKILL.md

Spatial Planning

Section 1: Floor Plan Archetypes

The floor plan archetype determines nearly every downstream design decision — structural grid, facade rhythm, servicing strategy, daylight penetration, and occupant experience. The ten canonical plan types below cover the full spectrum of building configurations from narrow residential slabs to deep-plan commercial towers.

1.1 Single-Loaded Corridor

Diagram description: A linear building with habitable rooms on one side only and an open corridor or gallery on the other, typically facing a courtyard or exterior view.

  • Typical plan depth: 6–9 m from corridor wall to exterior facade
  • Structural grid: 6–8 m bays perpendicular to corridor, 3–4 m bays parallel
  • Daylight characteristics: Excellent — all rooms have direct exterior exposure on at least one side; corridor receives borrowed light or is open-air
  • Circulation efficiency: Low — corridor serves rooms on one side only, yielding high circulation-to-usable area ratio (NTG penalty 5–10%)
  • Best-fit building types: Tropical housing, student residences, hospital wards, hotels in warm climates, gallery-access social housing
  • Exemplar buildings: Robin Hood Gardens (Alison & Peter Smithson, London, 1972); Park Hill (Jack Lynn & Ivor Smith, Sheffield, 1961)
1.2 Double-Loaded Corridor

Diagram description: A linear building with habitable rooms on both sides of a central corridor, creating a deeper floor plate.

  • Typical plan depth: 12–18 m total (two 6–9 m room depths flanking a 1.5–2.4 m corridor)
  • Structural grid: 6–8 m bays perpendicular, 3–5 m parallel
  • Daylight characteristics: Good in rooms; corridor is typically windowless and requires artificial lighting or periodic breaks with glazing
  • Circulation efficiency: High — corridor serves rooms on both sides, achieving 78–85% NTG in residential, 80–87% in hotel
  • Best-fit building types: Hotels, residential apartments, dormitories, hospital departments, budget office buildings
  • Exemplar buildings: Unite d'Habitation (Le Corbusier, Marseille, 1952); Trellick Tower (Erno Goldfinger, London, 1972)
1.3 Central Core

Diagram description: A floor plate organized around a central vertical core containing stairs, elevators, risers, and often toilets, with usable space radiating outward to the perimeter facade.

  • Typical plan depth: 9–15 m from core face to facade (18–30 m total floor plate dimension)
  • Structural grid: 9 m x 9 m or 10.8 m x 10.8 m typical for office; 8.4 m x 8.4 m for residential
  • Daylight characteristics: Good at perimeter (within 6–8 m of facade); deep zones beyond 8 m require artificial lighting; core zone is dark
  • Circulation efficiency: Excellent — shortest average travel distances, compact service distribution. NTG 75–82% for office
  • Best-fit building types: Office towers, mixed-use high-rises, commercial buildings over 10 storeys
  • Exemplar buildings: Seagram Building (Mies van der Rohe, New York, 1958); Swiss Re (Foster + Partners, London, 2004)
1.4 Side Core

Diagram description: The vertical core is positioned at one end or one side of the floor plate, freeing the remainder for uninterrupted usable space with maximum facade access.

  • Typical plan depth: 12–18 m from core to far facade
  • Structural grid: 9–12 m clear spans common to maximize open floor plate
  • Daylight characteristics: Excellent — core does not obstruct perimeter daylight; deep floor plates still need supplementary lighting beyond 8 m from facade
  • Circulation efficiency: Good — slightly longer travel distances than central core; single direction of egress requires careful code compliance (max 45 m travel distance IBC sprinklered)
  • Best-fit building types: Speculative offices (lettable floor plates), creative workspaces, laboratories, buildings on narrow urban sites
  • Exemplar buildings: Lever House (SOM, New York, 1952); One Angel Court (Fletcher Priest, London, 2017)
1.5 Point Tower

Diagram description: A compact, typically square or circular floor plate with a central or offset core, rising as a slender tower. Small floor plates (400–800 m²) with high perimeter-to-area ratio.

  • Typical plan depth: 6–10 m from core to facade
  • Structural grid: Radial or 6–8 m orthogonal grid
  • Daylight characteristics: Excellent — high perimeter-to-floor-area ratio ensures most space is within 6 m of facade
  • Circulation efficiency: Very high — compact core serves 4–8 units per floor in residential, or open-plan office. NTG 75–82% residential
  • Best-fit building types: Residential towers, boutique office towers, landmark/iconic structures, slender urban infill
  • Exemplar buildings: Barbican Tower (Chamberlin Powell & Bon, London, 1976); Aqua Tower (Studio Gang, Chicago, 2009)
1.6 Courtyard Plan

Diagram description: Building mass encloses or partially encloses a central open courtyard, creating inward-facing as well as outward-facing rooms.

  • Typical plan depth: 6–12 m building depth around 15–40 m courtyard dimension
  • Structural grid: 6–8 m bays; loadbearing masonry or frame
  • Daylight characteristics: Very good — dual-aspect units possible; courtyard provides sheltered daylight source. Courtyard must be min 1:1 width-to-height ratio for adequate light at lower floors
  • Circulation efficiency: Moderate — circulation wraps around courtyard, adding length but creating social/amenity corridor
  • Best-fit building types: Low-to-mid-rise housing (3–8 storeys), institutional (schools, monasteries, museums), hotels, mixed-use urban blocks
  • Exemplar buildings: Palazzo Farnese (Antonio da Sangallo/Michelangelo, Rome, 1534); Beurret & de la Croix housing (Valerio Olgiati, 2014)
1.7 Atrium Plan

Diagram description: A large internal void (atrium) rises through multiple storeys, with occupied floors opening onto galleries or balconies surrounding the void. The atrium is typically top-lit or side-lit.

  • Typical plan depth: 6–12 m from atrium edge to exterior facade; atrium 10–30 m wide
  • Structural grid: Long-span (12–15 m) to clear atrium void; 6–9 m in occupied wings
  • Daylight characteristics: Excellent at upper levels; diminishes at lower floors of deep atria. Atrium acts as light well. Glazed roof or clerestory essential
  • Circulation efficiency: Good — atrium acts as orientation device and social condenser; galleries double as circulation and informal meeting space
  • Best-fit building types: Corporate headquarters, shopping malls, hospitals, museums, civic buildings, hotels
  • Exemplar buildings: Bradbury Building (George Wyman, Los Angeles, 1893); Commerzbank Tower (Foster + Partners, Frankfurt, 1997)
1.8 Free Plan

Diagram description: Structural columns are set back from the facade on a regular grid, with non-loadbearing partitions freely arranged on each floor independently. The floor plan has no fixed interior walls tied to structure.

  • Typical plan depth: Variable — 12–20 m common
  • Structural grid: Regular grid (Dom-ino: 5 m x 5 m); pilotis or columns at ground; flat slabs
  • Daylight characteristics: Dependent on floor plate depth and window placement; facade is free from structural constraint enabling floor-to-ceiling glazing
  • Circulation efficiency: High — absence of loadbearing walls allows optimized corridor placement per floor
  • Best-fit building types: Modernist villas, flexible office space, galleries, retail, adaptable-use buildings
  • Exemplar buildings: Villa Savoye (Le Corbusier, Poissy, 1931); Farnsworth House (Mies van der Rohe, Plano, 1951)
1.9 Open Plan

Diagram description: A large, unpartitioned floor plate with minimal internal walls or divisions, typically with perimeter structure or long-span trusses enabling column-free interiors.

  • Typical plan depth: 18–30 m or more; limited only by daylighting (8 m effective daylit zone from each facade)
  • Structural grid: Long-span: 12–18 m (steel) or 9–12 m (concrete). Post-tensioned slabs common
  • Daylight characteristics: Moderate — perimeter zones well-lit, deep core zones require artificial light. Atriums or lightwells mitigate this
  • Circulation efficiency: Very high — minimal dedicated corridor space; NTG 82–88% achievable
  • Best-fit building types: Trading floors, tech offices, co-working spaces, warehouses, exhibition halls, large retail
  • Exemplar buildings: Willis Faber & Dumas (Foster + Partners, Ipswich, 1975); Centraal Beheer (Herman Hertzberger, Apeldoorn, 1972)
1.10 Hybrid Plan

Diagram description: Combines two or more plan archetypes within a single floor plate or building — for example, a central core office tower with an atrium zone and a double-loaded residential wing.

  • Typical plan depth: Variable — responds to mixed program
  • Structural grid: Transitional grids at junctions; transfer structures where grid changes
  • Daylight characteristics: Varies by zone — each archetype zone retains its own daylight characteristics
  • Circulation efficiency: Moderate — junctions between plan types create circulation complexity; careful wayfinding needed
  • Best-fit building types: Mixed-use developments, large civic buildings, university buildings, transport hubs, hospital complexes
  • Exemplar buildings: Linked Hybrid (Steven Holl, Beijing, 2009); De Rotterdam (OMA, Rotterdam, 2013)

Section 2: Circulation Design

Circulation consumes 15–30% of gross floor area depending on building type. Efficient circulation design directly impacts NTG ratio, user experience, code compliance, and emergency egress.

2.1 Primary Circulation

Lobbies:

  • Main entrance lobbies: min 3.0 m clear height, typically 4.5–6.0 m for commercial
  • Lobby area: 0.5–1.0 m² per person served in peak 5-minute arrival period
  • Elevator lobbies: min 1.5 m depth in front of elevator doors; 2.4 m preferred for office towers
  • Residential entrance lobbies: min 6 m² (BS 9991), concierge desk adds 4–6 m²

Corridors: Minimum corridor widths by building type and code:

Building TypeIBC MinimumBS 9999 MinimumRecommended
Office1118 mm (44 in)1050 mm1500–1800 mm
Residential (common)1118 mm (44 in)1050 mm1200–1500 mm
Hospital2438 mm (96 in)2100 mm2400–3000 mm
School1829 mm (72 in)1600 mm1800–2400 mm
Hotel1118 mm (44 in)1050 mm1350–1500 mm
Retail1118 mm (44 in)1200 mm1800–3000 mm
Assembly1118 mm (44 in)1200 mm2400+ mm

Dead-end corridors (IBC 1020.4):

  • Unsprinklered: max 6.1 m (20 ft)
  • Sprinklered: max 15.2 m (50 ft)
  • Group I-3 (detention): 15.2 m max regardless
  • Exception: single-exit dwelling units per IBC 1006.3.4

Travel distance limits (IBC Table 1017.2):

  • Unsprinklered: 60 m (200 ft) for most occupancies; 23 m (75 ft) for H-1/H-2 hazardous
  • Sprinklered: 76 m (250 ft) for most; 30 m (100 ft) for H-1/H-2
  • Common path of egress: 23 m unsprinklered / 23 m sprinklered for most; 30 m for B/F/S/U occupancies (sprinklered)
2.2 Stair Design

IBC Requirements (Chapter 10):

  • Minimum width: 1118 mm (44 in) for occupant load >50; 914 mm (36 in) for ≤50
  • Riser height: min 102 mm (4 in), max 178 mm (7 in)
  • Tread depth: min 279 mm (11 in)
  • Riser-tread relationship: 2R + T = 600–640 mm (optimum 630 mm)
  • Uniform risers within a flight: max 9.5 mm (3/8 in) variation
  • Maximum flight height without landing: 3.66 m (12 ft)
  • Landing depth: min equal to stair width, need not exceed 1220 mm (48 in)
  • Headroom: min 2032 mm (80 in) measured vertically from nosing

This is the start of the file. Read the full SKILL.md on GitHub.

Security

  • Security scanPassed, 100 of 100Pattern checks on the skill's files.
  • Model reviewNot runA model review is scheduled for the next rescan.

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

Repository stars
158
Repository forks
31
7-day trend score
25

Stars and forks are for the whole GitHub repository, not this skill alone. Refreshed 28 Apr 2026, 6 months ago.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/amanbh997/skills-architects/spatial-planning/badge)](https://verified-skill.com/skills/amanbh997/skills-architects/spatial-planning)

Something wrong with this skill or its page? Tell us.