Steady-state and hygrothermal verification of opaque building elements and windows for DACH/European practice: heat protection (Wärmeschutz) with R/U/λ/ψ calculations per DIN EN ISO 6946, surface resistances, design thermal conductivity values, inhomogeneous build-ups, air layers, inverted-roof and fastener corrections, thermal-bridge linear transmittance (Ψ) auditing with fRsi temperature-factor and mould criteria (DIN 4108-2), GEG new-build and existing-building U-value checks for walls, roof…

Install

npx vskill@latest install felixkarevo/construction-skills/building-physics-thermal-moisture

SKILL.md

Building Physics: Heat & Moisture Protection (Bauphysik: Wärme- und Feuchteschutz)

Simple-first gate (governs how this skill is applied). Default every choice here to
the simplest proven solution at the agreed standard tier — see the governing skill
simple-first-building (complexity ladder §1). Escalate to more demanding construction
(innovative systems, one-off details, higher comfort tiers) only when the client
explicitly asks for it, with cost/schedule impact stated; deviate below the usual
standard or the aarRdT only via the documented risk-acceptance machinery
(simple-first-building §3) — public permission never cures the private default.

Use this skill when the agent must check, design-verify, or explain the thermal and hygric behaviour of an opaque building element, window, roof, or above/below- grade assembly: U-value compliance (GEG / DIN 4108-2 Mindestwärmeschutz), thermal bridges and Ψ values, interior surface temperature and mould risk (fRsi, 12.6 °C criterion), interstitial condensation by Glaser method, vapour-control layer and sd placement, airtightness (n50, blower door, DIN 4108-7 detailing), summer overheat proof (S-index / F_C / simulation limits), wind-driven rain, capillary moisture, and ground heat transfer. Trigger also on layer-buildup review requests ("is there a dew point in this wall?"), retrofit insulation sizing, window Uw assembly, or when a roof/wall section is proposed without a stated moisture strategy.

Sibling skills (call them, do not duplicate their scope):

  • building-acoustics — airborne/impact sound, DIN 4109 proofs (mass law, flanking).
  • fire-protection-building — reaction/fire-resistance classes, compartments, escapes.
  • roofing-waterproofing — waterproofing layer rules, detailing of seals, gutters.
  • building-materials — product data, λ/μ only as material properties, not proofs.
  • construction-detailing — joint grammar, layer continuity, three-stage sealing.
  • structural-systems — load paths, bracing, dimensioning of the structure itself.
  • construction-freecad-bim — geometry, sections, IFC export (see handoff section).

Units convention: λ [W/(m·K)], R [m²K/W], U [W/(m²K)], Ψ [W/(m·K)], χ [W/K], sd [m], μ [−], moisture content u [M-%], capillary coefficient W [kg/(m²·h^0.5)], vapour pressure p [Pa], temperatures θ [°C]. German term in parentheses at first use of each concept; numeric values always with the tier tag from the next table.

Reality check — not a construction document

  1. The agent produces planning and calculation aids (Planungs-/Nachweishilfen),

not enforceable construction documents. Every output of this skill must be labelled as such when it leaves the chat or a model.

  1. The statutory energy proof (energetischer Nachweis, GEG) requires a

zugelassenes Verfahren (accepted calculation procedure, e.g. DIN V 18599 or DIN V 4108-6/4701-10 as far as still permitted) executed and, where the Land law demands it, signed by a licensed Energieberater / Fachunternehmer. A hand-run U-value or S-index check from this skill is a pre-check, never the proof itself.

  1. GEG and DIN text in force at project date prevails over every number in

this file. The digests behind these values contain flagged editions (DIN 4108-2:2013-02, DIN 4108-3:2014-11, GEG 2020/amendments). Values marked VERIFY must be re-checked in the current norm/regulation text before use.

  1. When the user treats agent output as final ("das ist dann unser Nachweis"),

the agent must state explicitly: planning aid only; proof requires accepted procedure + licensed practitioner; current GEG/DIN text prevails; this check used flagged edition values.

  1. Condensation, mould, and airtightness verdicts from stationary methods

(Glaser, fRsi) carry method limits (stationary climate, constant properties, no construction moisture). For internal insulation, flat roofs, timber structures near risk thresholds, the honest answer is: stationary tier passed or failed — confirm with transient coupled heat-moisture simulation (DIN EN ISO 15026 tools of WUFI/DELPHIN class) before deciding.

Evidentiary tiers (never mix tiers in one number chain)

TierStatusExamples (this skill)
T1Law / legally-binding energy & safety requirementsGEG (§26 airtightness, §49 ff. requirements, Referenzgebäude), DIN 4108-2 Mindestwärmeschutz via Baurecht (Technische Baubestimmungen), Landesbauordnungen, EnEV-history flags
T2DIN/EN calculation methods and tabulated design inputsDIN EN ISO 6946 (R/U), 10211 (bridge numerics), 13788 (surface humidity), 10456 (λ/μ design), DIN 4108-3 (Glaser/period balance), DIN 4108-4/-6, DIN EN ISO 10077 (windows), 13370 (ground), 13786/13793, DIN V 18599
T3Recognised practice values (rules of technique / trade sheets)DIN 4108 Bbl. 2 planning examples, ZVDH Fachregeln/Produktdatenblätter, WTA-Merkblatt-style values, DIN 4108-7 material classification, window class tables DIN EN 12207
T4Rules of thumb (only for plausibility, never for proof)"1 cm good insulation ≈ 15 cm brick", Ψ≈0.05 typical bad junction, "U ≤ 0.28 beats most retrofit caps", 12.6 °C memory value

Mixing rule: a T1 limit (e.g. GEG U ≤ 0.20 roof) may be checked with T2 methods (ISO 6946) and T2/T3 input data (DIN 4108-4 λ_B), but a T4 estimate never closes a T1 requirement. If the only available number is T4, say so in the output.

1. Steady-state heat transfer (Wärmeleitung) — core calculation

1.1 Quantities and formulas (T2, DIN EN ISO 6946)
  • Heat flow rate: Φ = Q/t [W]; flux density q = Φ/A [W/m²].
  • Layer conduction: q = λ·(θ₁−θ₂)/d = Δθ/R_i, with R_i = d_i/λ_i [m²K/W].
  • Multi-layer (homogeneous layers): R = Σ R_i.
  • Total resistance: R_T = R_si + Σ(d_i/λ_i) + R_se.
  • U = 1/R_T [W/(m²K)] (U-Wert, Wärmedurchgangskoeffizient).
  • Whole element: q = U·(θ_i − θ_e); surfaces: q = h_i(θ_i−θ_si) = h_e(θ_se−θ_e).
  • Round R_T and U to 2 decimals (DIN 4108-2 convention).
  • Temperature at depth x: θ_x = θ_i − q·(R_si + Σ d_x/λ) — proportional-drop

method; graphical alternative: plot θ over cumulative R, straight line from θ_i (R=0) to θ_e (R=R_T); intermediate layer temps read at R boundaries.

  • Transient material response (context only): diffusivity a = λ/(ρ·c_p) [m²/s];

effusivity (Wärmeeindringkoeffizient) b = √(λ·ρ·c_p); low a ⇒ slow temperature wave (good phase shift: low λ, high ρ·c_p).

1.2 Surface coefficients / resistances (T2)

Convective design coefficients (ISO 6946): h_ci = 5.0 (heat flow upward), 2.5 (horizontal), 0.7 W/(m²K) (downward); exterior h_ce ≈ 4·v̄^0.4 (v̄ wind m/s); radiative h_r = ε·h_ro with h_ro (blackbody): −10 °C→4.13, 0→4.61, 10→5.10, 20→5.70, 30→6.31, 40→6.95, 50→7.64, 60→8.37 W/(m²K). ε ≈ 0.9 for most non-metallic materials (bright Al 0.05–0.07, polished Cu 0.03 — reflective foils work only with enclosed air gap).

Standardized surface resistances R_s = 1/(h_c+h_r) [m²K/W]:

SituationR_si (interior)R_se (exterior)Tier/note
Heat flow upward (roof)0.100.04T2 ISO 6946
Horizontal (wall, heat flow sideways)0.130.04T2 ISO 6946
Heat flow downward (floor)0.170.04T2 ISO 6946
Against ground / earth-coupled faceper direction (0.17/0.13/0.10)0T2
Thermal-bridge & mould checks (DIN 4108-2)0.250.04T1/T2 boundary value
Moisture verification Glaser (DIN 4108-3)0.250.04T2
Glazing / window frame surfaces0.13 (up 0.10 / down 0.17)0.04T2 13788/10077
Behind built-in (sealed-back) furniture1.0—T2 DIN 4108-8
Behind free-standing furniture0.5—T2 DIN 4108-8
Strongly ventilated air layer replaces layer—use R_si value on that faceT2 ISO 6946

R_si = 0.25 is the verification-only value (slow surface convection assumed for hygrothermal checks); U-values for energy law use 0.10/0.13/0.17. Never mix the two in one chain. Unheated adjacent space: R_se of that face = R_si of the unheated space; or use F_x temperature correction (thermal-bridge section) — but never both Ru-method and F_x-method together (double count).

1.3 Design thermal conductivity λ_B and moisture rule (T2, DIN 4108-4 / DIN EN ISO 10456)

Design values (Bemessungswerte) refer to hygroscopic equilibrium moisture at 23 °C / 80 % RH. Conversion from declared λ_D per material family (footnote rules captured in digests):

  • λ_B = λ_D·1.03, min +1 mW/(m·K): MW, EPS, XPS, PUR, PF, CG, EPB, WW, WF, in-situ MW, EP in-situ.
  • λ_B = λ_D·1.05 min +2; ·1.10 min +3 (PUR/PIR spray & dispensed EN 14315/-18: 0.020→0.023 … 0.040→0.044); ·1.20 (vermiculite EN 14317, PEF EN 16069); ·1.23.
  • Metal-faced sandwich (EN 14509): U_B = U_D·1.03.
  • Quartz-sand note: +20 % λ for 2-chamber, +15 % for 3–6-chamber hollow blocks.
1.4 λ / μ / c_p table — common materials with design densities (T2, DIN 4108-4 style; μ dry/wet where given)

This is the start of the file. Read the full SKILL.md on GitHub.

Security

  • Security scanPassed, 100 of 100Pattern checks on the skill's files.
  • Model reviewNot runA model review is scheduled for the next rescan.

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

7-day trend score
0

Not refreshed yet.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/felixkarevo/construction-skills/building-physics-thermal-moisture/badge)](https://verified-skill.com/skills/felixkarevo/construction-skills/building-physics-thermal-moisture)

Something wrong with this skill or its page? Tell us.