<< All versions

Skill v1.0.0

currentAutomated scan100/100
felixkarevo/construction-skills/construction-freecad-bim
──Details
PublishedNovember 17, 2026 at 11:00 AM
Content Hashsha256:12ad3115e0301fa7...
Git SHAa0e95e060d5e
──Files
Files (1 file, 107.3 KB)
SKILL.md107.3 KBactive
SKILL.md · 1809 lines · 107.3 KB

name: construction-freecad-bim description: > Core modeling skill of the construction-design library: real, structurally verified BIM models in FreeCAD 1.x through a live GUI driven by the neka-nat/freecad-mcp bridge — Site/Building/Storey hierarchy, live parametric openings via Subtractions (never frozen booleans), classified makeStructure members, makeRebar cages, code-gated stairs, MEP risers/shafts, CalculiX FEM verification via run_fem_analysis, IFC import (NativeIFC, locked/unlocked modes) and export proven by parsing, renovation/retrofit modeling (Bestand baseline, Sanierungsstatus phase tagging, delta-volume tracking, degraded- material FEM overrides). Verify-by-measurement after every placement; honesty protocol: no member is adequate without solver output. Design values defer to sibling skills (concrete-detailing, structural-analysis, geotechnics-foundations, ...); this file owns modeling mechanics and MCP bridge behaviour. metadata: version: "1.0.0"


FreeCAD BIM Modeling & Structural Verification — Core Skill

Simple-first gate (governs how this skill is applied). Default every choice here to
the simplest proven solution at the agreed standard tier — see the governing skill
simple-first-building (complexity ladder §1). Escalate to more demanding construction
(innovative systems, one-off details, higher comfort tiers) only when the client
explicitly asks for it, with cost/schedule impact stated; deviate below the usual
standard or the aarRdT only via the documented risk-acceptance machinery
(simple-first-building §3) — public permission never cures the private default.

This is the core file of a 33-skill construction-design library. It teaches an MCP-capable agent to produce honest, parametric, solver-checked building models inside a live FreeCAD 1.0.x GUI. Everything geometry-technical here was validated against FreeCAD 1.0.1 through the MCP bridge (CalculiX ccx and gmsh present) and against the object-by-object study of FreeCAD's bundled example building usr/share/examples/BIMExample.FCStd (361 objects: 41 walls, 18 doors, 18 windows, 9 slabs, 7 stairs, 5 storeys). The worked example bundled in this repository (model/) documents the same object discipline on a compact residential building.

Markers: [verified] = executed live on FreeCAD 1.0.1 through this bridge — evidence. [unverified] = knowledge not round-tripped through the solver or the running instance — a lead to confirm, not evidence.

Reality Check — Licensing & Liability

This skill produces design aids, dimensional guidance and modeling workflow for planning and FreeCAD modeling ONLY. It does not produce engineering design.

  • Any design for actual construction of a real occupied building MUST be reviewed,

sealed and stamped by a licensed structural engineer — in DACH the Tragwerksplaner who signs the bautechnischer Nachweis, typically countersigned by a Prüfingenieur per the Landesbauordnung — and MUST pass local authority approval (Baugenehmigungsverfahren with B-Plan/BauNVO zoning, setback, coverage, height). See building-regulations-permits.

  • A CalculiX/FEM result from this workflow is a screening check, not a design: linear-

elastic, isotropic, homogeneous, small-displacement, single-load-case, mesh-dependent. For concrete it does not model cracking, tension stiffening, creep, shrinkage, long-term deflection, bar bond/anchorage, punching shear, or seismic/wind demand; no buckling, fatigue or connection checks. Passing it does not mean a member is safe.

  • Soil bearing capacity used here is an assumed value; real footings need a

geotechnical investigation (geotechnics-foundations). Frost depth, water table, expansive/collapsible soils, fill, site class: not knowable from a model.

  • Reinforcement modeled here is geometry, not a detailing design — development

lengths, laps, hooks, curtailment and confinement detailing follow the Eurocode rules owned by concrete-detailing (seismic: seismic-design). Cite and defer; never re-derive here.

The agent must never present FreeCAD output as construction-ready. If the user's language treats it as final — "so I can start building", "send this to the contractor", "is this safe", "final footing size", "can I pour this" — say so unprompted, first, in that reply. See §7.3 for the exact status-block protocol.

How this library fits

This file is the modeling engine. The other 31 skills own the why behind every number. When a question here becomes a design question, switch to the owning skill — never improvise a design value from a modeling recipe.

SkillOwns (one line)
simple-first-buildingGOVERNING gate: standard tier + complexity ladder — every model object defaults to the simplest proven solution; escalations and downward deviations only via its documented decision machinery.
building-planning-spatialRoom programs, dimensions, circulation, planning grid — the plan this file models.
building-typologyBuilding types, housing forms, massing and typological section patterns.
structural-systemsLoad-bearing system choice, load-path narrative, preliminary span/depth sizing tables.
structural-analysisStructural action: load combinations, internal forces, deflection and stability checks — the hand calc every FEM run is compared against.
concrete-detailingEurocode (EN 1992) reinforcement rules: cover by exposure class, min/max steel, anchorage, laps, stirrups, bar schedules.
masonry-constructionMasonry build-up, wall types, EN 1996 constraints, confined-masonry practice.
timber-steel-designTimber (EN 1995) and steel (EN 1993) member and connection design.
geotechnics-foundationsSoil investigation, bearing capacity, settlement, retaining, foundation type selection.
seismic-designEarthquake action, regularity rules, ductility and confinement detailing (EN 1998).
construction-detailingPhysical junction details: DPC/DMP layers, sills, head conditions, movement joints.
building-materialsMaterial properties, unit weights, selection and specification.
building-physics-thermal-moistureHygrothermal performance: U-values, condensation, airtightness, build-up order.
building-acousticsSound insulation, room acoustics, flanking, separating-element rules.
fire-protection-buildingFire compartments, reaction classes, resistance periods (F30–F120), escape routes.
roofing-waterproofingRoof build-ups, falls, drainage, membrane and tile detailing.
openings-windows-doorsWindow/door design, lintels, sills, installation joints, glazing.
stairs-vertical-circulationStair geometry rules and the hard code gates this file's stair checks are parameterized with.
accessibility-universal-designBarrier-free design (DIN 18040): widths, ramps, tolerances beyond minimums.
building-services-tgaTGA engineering: risers (Steigstränge), shafts (Installationsschächte), plant rooms, penetration coordination.
construction-scheduling-siteTime: schedules, sequence, site logistics, crane and laydown planning.
cost-management-din276Cost per DIN 276 cost groups, quantities-to-cost mapping, BOQ discipline.
building-regulations-permitsBylaws, setbacks, GRZ/GFZ, permit workflow, submissions.
sustainable-constructionEmbodied carbon, circularity, material passports, certification systems.
existing-structures-retrofitBuilding in existing conditions: assessment, Nachrechnung, strengthening, envelope retrofit.
building-renovation-refurbishmentComponent-level renovation technique: Bestandsaufnahme, repair systems per building element, energetic/ecological retrofit workflow, Abbruch/Rückbau — the source of what §3.10's renovation modeling pattern renders.
timber-building-renovationHistorical timber diagnosis and repair: Schadensanalyse/-bewertung, Ertüchtigung technique, Fachwerk/Umgebindebau — the source of §3.10's degraded-material override numbers for timber.
bim-managementThe BIM process: naming, LOIN/LOI/LOG (DIN EN 17412), MVD, CDE, IFC validation — the deep data discipline touched only lightly here.
ifcopenshell-bim-authoringSibling modeling skill without FreeCAD: IFC as source of truth via ifcopenshell.api / ifcmcp, one file per discipline — use it when the deliverable is native IFC.
construction-drawing-sketchingDrawing and sketch representation of the model: line weights, hatching, sheet craft.

Reading order

  1. This file + `building-planning-spatial` — first; you cannot model what is not

planned, and cannot plan what you cannot keep parametric.

  1. building-typology → structural-systems — kind of building, load-bearing system.
  2. structural-analysis → concrete-detailing → geotechnics-foundations — the numbers

the model must carry honestly; then the material/hazard track: masonry-construction / timber-steel-design / seismic-design.

  1. openings-windows-doors → stairs-vertical-circulation → roofing-waterproofing →

construction-detailing — whose rules §3's recipes assert by measurement; then building-materials → building-physics-thermal-moisture → building-acoustics → fire-protection-building — performance properties that ride on the IFC export (§4).

  1. building-services-tga → accessibility-universal-design — coordination and

use-quality passes.

  1. building-regulations-permits → sustainable-construction →

construction-scheduling-site → cost-management-din276 — compliance, lifecycle, time and money frame.

  1. bim-management → construction-drawing-sketching — how the model is exchanged,

validated and drawn for humans.

1. Setup — the FreeCAD ⇄ MCP bridge

Source of truth for the bridge: https://github.com/neka-nat/freecad-mcp (the tool — the only external project this file names). The bridge = a FreeCAD addon exposing an RPC server inside the running GUI + an MCP server any MCP-capable agent client registers. Tool names are usually prefixed by the server name (e.g. mcp__freecad__execute_code); bare names are used here.

1.1 Install (one-time, needs a human)

  1. FreeCAD 1.0+, GUI build. The bridge drives a live GUI — no headless mode: under

Xvfb the GUI thread hangs forever and every RPC call times out with no error.

  1. Put the addon's addon/FreeCADMCP folder into the FreeCAD Mod directory —

Linux ~/.local/share/FreeCAD/Mod; Windows %APPDATA%\FreeCAD\Mod; macOS (1.1) ~/Library/Application Support/FreeCAD/v1-1/Mod.

  1. Restart FreeCAD → MCP workbench → "Start RPC Server". "Auto-Start Server"

persists the choice in freecad_mcp_settings.json.

  1. Start the MCP server for the agent side: uvx freecad-mcp (or uv run from a cloned

repo); register it in any MCP-capable agent client's config as an mcpServers entry.

1.2 The tool surface

ToolUse it for
create_documentNew/replace target document.
create_object / edit_object / delete_objectSingle-object CRUD by class/property — fine for boxes, too crude for parametric recipes (use execute_code, G-35).
execute_codePython on the GUI thread; the workhorse for §3.
execute_code_asyncLong computation off-thread, then commit(fn, timeout=120) applies results on the GUI thread (§1.4, G-23).
insert_part_from_libraryPull a prepared solid (e.g. multi-part window/door template) into the document (G-34).
get_object / get_objects / list_documentsRead properties/shape metadata; list open docs.
get_viewA screenshot of the GUI (§1.3).
get_rpc_statusDispatch queue alive or stuck? (§1.4, §6.1)
run_fem_analysisRuns CalculiX on an already assembled Fem::FemAnalysis; auto-creates SolverCcxTools; returns max/min von Mises, max displacement, node count, working dir, result object.

1.3 Screenshot control — token economy (G-30)

  • Every screenshot-capable call takes include_screenshot and view_name

(Isometric | Front | Top | Right). include_screenshot=False is the default for anything analytical (face dumps, property reads, assertions, meshing, load arithmetic, FEM numeric runs); True only when a human should see the change, the final view, or the one FEM run whose stress picture is the deliverable. Pick view_name to show it: Front for an elevation, Top for a plan, Isometric for massing.

  • Launch the server with --only-text-feedback to strip images from all responses —

cheapest mode for long builds; re-enable selectively per call.

1.4 Timeouts, queueing and the GUI thread — the rules that prevent hangs

  • RPC work is a FIFO queue on the GUI thread (G-28): one operation at a time, in

order. Never fan out parallel FreeCAD calls around a solver or any long operation.

  • execute_code budget: 90 s queue + 90 s execution; client socket up to 210 s

(G-22). Longer work must be split into smaller calls — never "just raise the timeout".

  • run_fem_analysis: request timeout per compute budget; **client socket ≥ 2×timeout
  • 30 s** (queue + execution) (G-33).
  • Never long-block the GUI thread (G-23): a solve, giant mesh or heavy boolean held

there freezes every other RPC — including doc.save(). Use execute_code_async: build off-thread, then commit(fn, timeout=120) to apply on the GUI thread.

  • GUI_DISPATCH_STUCK or get_rpc_status → "stuck": GUI thread blocked — **stop

queuing**, recover per §6.1.

  • execute_code runs in a persistent namespace with FreeCAD/App/Gui aliases

(G-27): variables survive across calls and are NOT clean after failures — keep calls self-contained. After an exception (especially dev/nightly builds), inspect the `Proxy` of any half-built FeaturePython object before mutating the document (G-29); delete-and-rebuild beats patch-in-place (§6.2).

1.5 Remote access (only if the human asks) — G-32

RPC listens on localhost only by default. Remote use needs the workbench's Remote Connections option + Allowed IPs (CIDR) + the server's --host flag — an explicit user security decision, never a convenience to enable silently.

1.6 Connection preflight — before touching the model

StepCallPass condition
1. RPC alive?get_rpc_statusnot stuck; if stuck, restart per §6.1
2. Documentslist_documentstarget present, or create_document
3. Solver binariesexecute_code: check ccx and gmsh on PATHboth [verified present on 1.0.1] before any FEM plan
4. Versionexecute_code: App.Version()1.0.x — §5 gotchas are 1.0-specific

1.7 Scripting discipline inside execute_code

  • try/except + print the traceback around risky blocks — uncaught exceptions return

terse, diagnostic-free failures. doc.recompute() after every structural change (G-08); fetch by Label (G-01); print explicit PASS/FAIL for every assertion — a silent script proves nothing.

  • One element per call, verified, saved (doc.save()) — increments, not monoliths

(§6.1 for why).

2. Modeling discipline — the doctrine

2.1 Spatial hierarchy — always build this first

Real BIM is Site > Building > Storey(s) > elements, not a flat document — in IFC the spatial decomposition tree (IfcSite → IfcBuilding → IfcBuildingStorey; elements attached by spatial containment). A flat document exports as orphaned objects no coordinator can schedule. Each storey carries a real Elevation (mm); assign elements via spatial.assign_container or the storey's Group. Build it before placing a single wall — the bundled reference model has 5 storeys, each at a distinct real elevation.

python
site = Arch.makeSite(name="Site")
building = Arch.makeBuilding(name="Building")
ground = Arch.makeFloor(name="Ground Floor") # IfcType "Building Storey"
ground.Elevation = 0
upper = Arch.makeFloor(name="Upper Floor")
# CRITICAL (G-12): Elevation is DERIVED from Placement.Base.z — set it through Placement:
p = upper.Placement; p.Base.z = 3200; upper.Placement = p # mm, matches ground wall height
# nest: site contains building, building contains floors, floors contain elements

The bundled reference model had 5 storeys, each at a distinct real Elevation — build the hierarchy before placing a single wall.

Storey scheme for a house with foundations:

Storey labelElevation (mm)Contains
Foundationnegative (e.g. −1200)footings, pile caps, PCC/lean layer, plinth beams below DPC
Plinth−450 to 0plinth beam, plinth walls, fill, DPC
Ground Floor0slab-on-grade, walls, columns, doors/windows
Upper Floor+3200suspended slab, walls, stair landing
Roof+6400roof slab, parapet, water-tank base

Footings belong to the Foundation storey — filed under Ground Floor they schedule and quantify wrong and read as above-grade in IFC.

2.2 One source of truth — parametric objects, not baked geometry

  • Wall openings = live `Subtractions` with hidden void solids (§3.1) — never a

one-off Part::Cut pasted back; a frozen boolean can't take a second window, can't be schedule-counted, can't be re-verified. Repeated patterns = one source shape arrayed/cloned (§3.1), not N cuts.

  • Structural elements = Arch.makeStructure with real properties (§3.3) — a Part::Box

carries no BIM classification: no foundation/column in IFC, no schedule, no take-off. Rebar = Arch.makeRebar on host-face sketches (§3.4), never drawn wires.

  • Positions that matter are constrained sketches — unconstrained geometry drifts on

recompute and every downstream BoundBox check silently changes meaning.

2.3 Naming and classification conventions

  • name= sets Label, not Name (G-01); fetch by Label. Pattern <Role>_<ID>:

PadFooting_F1, Column_C1, Wall_W-N-01, Win_W1-N01, Door_D-G01, Rebar_F1-B1 — stable IDs matter because verification stamps (§7.5) and bar marks attach by object identity.

  • Every object: correct IfcType proven by export+grep (§4.4), not by property value.
  • Helper solids Void_* are named, always hidden, and remain part of the parametric

chain (openings are verified against their BoundBoxes, §3.5) — never rename/delete casually.

  • Project-wide naming/Pset/MVD conventions come from bim-management (BEP

BIM-Abwicklungsplan / AIA if one exists); this file enforces: label-fetchable, stable, classification proven.

2.4 Verify-by-measurement — after EVERY placement, no exceptions

  1. BoundBox — print obj.Shape.BoundBox immediately after every Placement set on

any makeStructure object; compare to intended world coordinates before the next step depends on it (catches G-13/G-19 at placement time).

  1. Volume diff — every boolean cut must move Shape.Volume by the expected amount

(§3.1); a no-op cut is invisible in a screenshot, obvious in a diff.

  1. Export-and-grep — every claimed IFC classification must round-trip (§4.4).

Asserts print PASS/FAIL. "No error" is not "it worked".

2.5 Level of Information Need — minimum-information principle

Model only what the agreed use case needs (DIN EN 17412 LOIN: geometry LOG + information LOI per object type and milestone; process depth in bim-management):

  • The bundled reference shows what a real shipped example doesn't bother with: wall

Material/IfcProperties empty even on finished walls, TechDraw minimal. Do not over-invest in Psets/materials or drawing sheets unless construction documents were requested — matching the reference's priorities is calibration, not laziness.

  • Exception: structural members are never "schematic". A footing, column, beam, slab

or rebar object with no real dimensions, concrete class and steel is not a detail level — it is a false structural claim. Model it properly (§3.3–§3.4) or leave it out and say it is absent.

Effort calibration:

AskBuildSkip
"show me the massing / layout"hierarchy, walls, openings, slabsrebar, FEM, materials, TechDraw
"model my house"+ doors/windows as BIM objects, stairs with §3.6 gates, footings with real sizesFEM unless a member is claimed adequate
"is this beam OK / can this span"+ FEM per §3.8, hand-check, convergencePsets, drawing sheets
"prepare it for my engineer"+ rebar cages, bar schedule, IFC export, §7.3 status blocknothing — this is the full pass

2.6 System-family thinking — define once, instance many

The reference model's repeated elements follow one pattern: one profile/void/member definition, then Draft.make_ortho_array / Draft.make_clone instances pointing at the source. When a whole build-up repeats (wall type, floor type, riser group), fix its section once (sketch or preset) and place instances along the plan grid — the same type/instance split IFC mapping exploits, where the export target reads it (§2.5).

2.7 Units — the #1 source of silent 1000× errors

FreeCAD's internal system is mm, kg, s (force = mm·kg/s² = milli-newtons; pressure = kg/(mm·s²)).

QuantityAssign asRead back asTrap
Length"3000 mm" or float mm.getValueAs("mm").Valuebare floats are mm — fine
Force"21600 N" (string).getValueAs("N").Valueraw print shows 21600000.0 mm*kg/s^2
Pressure / stress"0.005 MPa" (string).getValueAs("MPa").Value1 MPa = 1000 internal units; bare float 1000× wrong
Density"2400 kg/m^3".getValueAs("kg/m^3").Value—
Young's modulus"30000 MPa"—material dict values are strings with units
Angle"90 deg".getValueAs("deg").ValuePlacement rotations take degrees

Always assign quantities as unit-bearing strings; always read with `.getValueAs()`. Never compare a raw quantity to a float. (G-04, G-21.)

3. Recipes — every element, start to finish

All code runs inside `execute_code` (FreeCAD 1.x Python; persistent App/Gui aliases per §1.4 — assume import FreeCAD as App, Draft, Arch and doc = App.ActiveDocument at each call top so calls stay self-contained).

3.1 Walls with live parametric openings

What does NOT work reliably: window.Hosts = [wall] alone does not cut the wall (verified: zero volume difference) (G-07). What works: wall.Subtractions performs a real, live, parametric boolean cut — the subtracted object must be a plain solid: a Part::Extrusion of a 2D sketch rectangle (or a Draft.Array/Draft.Clone of one for repeats), not the Window/Door BIM object. Arch.makeVoid produces a purpose-built void for the same slot [unverified here]; the sketch+extrusion path is the verified one.

python
sketch = doc.addObject("Sketcher::SketchObject", "VoidProfile_W1-N01")
# ... constrain to a WxH rectangle at the opening's local wall-face position ...
void = doc.addObject("Part::Extrusion", "Void_W1-N01")
void.Base = sketch
void.DirMode = "Normal"
void.LengthFwd = wall.Width + 100 # through-cut with margin
void.Solid = True
void.ViewObject.Visibility = False # void shapes are always hidden
before = wall.Shape.Volume
wall.Subtractions = wall.Subtractions + [void] # the live cut
doc.recompute()
after = wall.Shape.Volume
cut_m3 = (before - after) / 1e9
expected_m3 = (w_mm * h_mm * wall.Width.Value) / 1e9
print(f"cut={cut_m3:.4f} m3 expected~{expected_m3:.4f} m3 "
f"-> {'PASS' if before > after else 'FAIL: NOTHING WAS CUT'}")

For a repeated facade pattern, build ONE void, then Draft.make_ortho_array / Draft.make_clone it and subtract the array/clone — the bundled reference does exactly this for its ribbed office facade (one Extrude001 void, arrayed via Array003 / Clone001, both hidden, both in wall.Subtractions). One source shape edits the pattern.

Arch.makeStructure objects (footings, columns, beams) also expose Subtractions [verified] — same technique cuts a service penetration through a beam or a sleeve through a footing. Every such penetration is a structural event: it invalidates any prior FEM result for that member (§7.4) and, in beams, may be prohibited in the tension zone or near supports (building-services-tga + concrete-detailing). And cuts re-index faces: re-dump (§3.8.2) after every change (G-06).

3.2 Floors and slabs

Arch.makeFloor creates the storey container (IfcType "Building Storey") — remember its Elevation is set through Placement.Base.z (G-12). Slabs are elements inside it:

python
slab = Arch.makeStructure(length=6000, width=4000, height=150, name="Slab_S1")
slab.IfcType = "Slab"
p = slab.Placement; p.Base = App.Vector(3000, 2000, 3050); slab.Placement = p
doc.recompute()
print(slab.Shape.BoundBox) # CHECK NOW: "Slab" centers X/Y on Placement.Base (G-13)

The G-13 consequence for slabs: placed as if Base were a corner, the whole footprint sits shifted by half its plan size — and a world-coordinate Void_* then cuts 0.000 m³, no error. Print BoundBox, fix Placement, then cut. Slab thickness is a structural-analysis question; once chosen, model a real Height and verify V = L·W·H / 1e9 m³.

3.3 Columns, beams, footings, lintels — the makeStructure convention

Arch.makeStructure(length, width, height, name) produces a Part::FeaturePython that accepts a real IfcType and exports correctly [verified: `IFCFOOTING` in exported .ifc]. This is the one factory for rectangular structural elements.

python
ftg = Arch.makeStructure(length=1500, width=1500, height=450, name="PadFooting_F1")
ftg.IfcType = "Footing" # exports as IFCFOOTING [verified]
doc.recompute()
assert round(ftg.Shape.Volume/1e9, 4) == 1.0125 # m3 — verify by volume, always

Structural `IfcType` → FreeCAD object map:

ElementFactoryIfcTypeIFC entity
Pad / isolated footingArch.makeStructureFootingIFCFOOTING [verified]
Strip / wall footingArch.makeStructure (long, thin)FootingIFCFOOTING
Raft / matArch.makeStructure (full plan, thick)Footing or SlabIFCFOOTING / IFCSLAB [unverified]
PileArch.makeStructure (cylinder base)PileIFCPILE [unverified]
Pile capArch.makeStructureFootingIFCFOOTING [unverified]
Plinth / grade beam (Ringbalken)Arch.makeStructureBeamIFCBEAM
Column (Stütze)Arch.makeStructureColumnIFCCOLUMN
Beam / lintel (Sturz)Arch.makeStructureBeamIFCBEAM
SlabArch.makeStructureSlabIFCSLAB
PCC / lean blindingArch.makeStructureFooting (or plain solid, labelled)—
RebarArch.makeRebarReinforcing BarIFCREINFORCINGBAR [verified]

The centering rule (G-13, the one that eats half-days) — verified on 1.0.1:

  • Column/Slab (vertically extruded): X,Y centered on Placement.Base; Z

corner-based (extends +Height upward).

  • Beam/Footing (horizontally extruded): X corner-based (extends +Length);

Y,Z centered on Placement.Base.

A lintel assuming corner-Z lands centered on its level — a 150 mm-deep lintel intended with head at z sits 75 mm too low, dipping into its own opening. Always print `Shape.BoundBox` right after setting `Placement` and compare to intended world coordinates.

Lintels. Every window/door head under a load-bearing run requires a lintel (IfcType="Beam") — not floating masonry; an unlintelled opening is a structural omission, and if left out goes under "Not modelled" in §7.3. Bearing lengths / edge distances: openings-windows-doors + masonry-construction / concrete-detailing.

Footings. Type is a decision, not a default — route through geotechnics-foundations:

Geotechnical report with MEASURED allowable bearing pressure?
├─ NO → you may NOT state a final size. Model a placeholder labelled
│ "ASSUMED <q> kPa — REQUIRES GEOTECH" and say so in the reply (§7.3).
└─ YES → q_allow known
├─ line load (wall) → STRIP footing (practice rule width ≈ 2–3 × wall thickness)
├─ point load (column) → PAD footing
├─ close/edge columns → COMBINED — engineer
├─ pads > ~50 % of plan → RAFT — out of scope here, engineer
├─ weak/expansive soil → PILES — out of scope here, engineer
└─ retaining/sloping → engineer (geotechnics-foundations)

Model out-of-scope cases as clearly-labelled placeholders if the user needs the massing — never as if sized. Pad/strip sizing arithmetic (A = P/q_allow; add footing self-weight + overburden before declaring the bearing check passed — the commonest arithmetic omission; eccentricity limits) is owned by geotechnics-foundations + structural-analysis. The modeling-side check that stays here:

python
def check_strip_footing(ftg, wall_thk_mm, line_load_kN_per_m, q_allow_kPa,
min_width_factor=2.0, min_thk_mm=200):
# min_thk/factors: PLACEHOLDER practice values — pass project minima from
# geotechnics-foundations + concrete-detailing explicitly.
B = min(ftg.Length.Value, ftg.Width.Value) # footing width, mm
h = ftg.Height.Value
q_act = line_load_kN_per_m / (B / 1000.0) # kPa
rows = [
(f"width >= {min_width_factor:g}x wall", B >= min_width_factor*wall_thk_mm,
f"{B:.0f} vs {min_width_factor*wall_thk_mm:.0f} mm"),
(f"thickness >= {min_thk_mm} mm", h >= min_thk_mm, f"{h:.0f} mm"),
("bearing q_act <= q_allow", q_act <= q_allow_kPa, f"{q_act:.0f} vs {q_allow_kPa:.0f} kPa"),
]
for n, ok, v in rows:
print(f" [{'PASS' if ok else 'FAIL'}] {n} {v}")
return all(r[1] for r in rows)

Model the PCC/lean layer (typically 75–100 mm blinding under the footing) as a separate solid: omitting it puts the cage at the wrong absolute elevation, cascading into plinth and floor levels. Assign every foundation element to the Foundation storey (§2.1).

Plinth/grade beams — the element most often forgotten. Isolated pads without a plinth/grade beam tying them have no mechanism against differential settlement and no path to distribute seismic base shear (seismic-design). Model as IfcType="Beam" on the Plinth storey at/just below DPC, spanning pad-to-pad, wall-thickness wide × 225–300 mm deep [practice placeholder — owner: structural-systems]. If omitted, list under "Not modelled" in §7.3 — an absent tie beam is a real structural difference, not a detail level.

Cover is modeled geometry, not a note. Nominal cover comes from concrete-detailing (exposure classes, Eurocode); it sets makeRebar(offset=...) (§3.4) and effective depth d = h − cover − (tie dia) − ø_main/2. Model that arithmetic explicitly — wrong cover on the earth face of a footing is the commonest way a modeled cage is quietly wrong.

3.4 Rebar cages as real parametric objects

Scope: how to build a cage in FreeCAD and measure it. Min/max steel, cover tables,
tie spacing, development lengths, laps, hooks, curtailment, bar bending schedules and
confinement detailing are Eurocode rules owned by concrete-detailing (seismic:
seismic-design). Numeric limits below are passed in as parameters or marked
[placeholder] — design values are never owned by this file.

`Arch.makeRebar(baseobj, sketch, diameter, amount, offset, name)` [verified] — needs a sketch attached to a host face describing one bar's path; replicates it amount times and computes Spacing and TotalLength itself.

python
import Part
ftg = doc.getObjectsByLabel("PadFooting_F1")[0]
sk = doc.addObject("Sketcher::SketchObject", "RebarPath_F1_B1")
sk.AttachmentSupport = [(ftg, "Face5")] # Face5 = bottom face of a box [verified]
sk.MapMode = "FlatFace"
doc.recompute()
sk.addGeometry(Part.LineSegment(App.Vector(-600,-600,0), App.Vector(600,-600,0)), False)
doc.recompute()
rb = Arch.makeRebar(ftg, sk, diameter=12, amount=7, offset=75, name="F1_Bottom_X")
doc.recompute()
print(rb.IfcType, rb.Amount, rb.Diameter, rb.Spacing, rb.TotalLength)
# -> Reinforcing Bar 7 12.0 mm 225.0 mm 8400.0 mm [verified]

[verified] — properties: Amount, Diameter, Direction, Distance, Host, Mark, Material, OffsetStart, OffsetEnd, Rounding, Spacing, TotalLength, IfcType = "Reinforcing Bar"; exports as `IFCREINFORCINGBAR`.

Rules of use, each earned:

  • offset = the cover from concrete-detailing (validated recipe used 75 for

earth-cast); never 0.

  • `Direction` defaults to `(0,0,0)` → set it explicitly (G-14) [verified]: with zero

Direction, amount=51, offset=75 on a 10287 mm strip returned Spacing=3 mm (bars spread over 2·offset, not the host); setting rb.Direction = App.Vector(0,1,0) to the real replication axis gave Spacing=202.7 mm. Verify Spacing ≈ L_host/(amount−1) before trusting the cage — it never infers direction from sketch or host.

  • Spacing is derived; to hit a target, amount = floor((L − 2·cover)/s_target) + 1.

TotalLength is the authoritative bar-schedule quantity (take-off below).

  • host.Armatures stays empty in the scripted path — check rb.Host (G-05).
  • OffsetStart/OffsetEnd default 30 mm — bars extend 30 mm past their wire endpoints;

too short to be real lap/anchorage, so zero them unless modeling a lap deliberately (feeds G-15).

  • Rounding = bend radius as multiple of bar diameter [unverified]; minimum bend per

concrete-detailing — 0 models an unbuildable sharp bend. Mark = bar mark (F1-B1, C1-MAIN, B2-STIRRUP) so the take-off reads.

  • A full cage = two orthogonal bottom mats (one sketch per direction) + top steel

where continuous/cantilevered.

Stirrups/ties = closed-loop sketch on a cross-section face, replicated along the member axis [unverified pattern — follows from verified straight-bar behaviour]:

python
col = doc.getObjectsByLabel("Column_C1")[0] # 300 x 300 x 3000
sk = doc.addObject("Sketcher::SketchObject", "TiePath_C1")
sk.AttachmentSupport = [(col, "Face5")] # bottom cross-section face
sk.MapMode = "FlatFace"
doc.recompute()
c = 40 # cover to tie — per concrete-detailing
a, b = 150 - c, 150 - c
pts = [App.Vector(-a,-b,0), App.Vector(a,-b,0), App.Vector(a,b,0), App.Vector(-a,b,0)]
for i in range(4):
sk.addGeometry(Part.LineSegment(pts[i], pts[(i+1) % 4]), False)
doc.recompute()
# amount from the tie-spacing rule in concrete-detailing, not from taste:
tie = Arch.makeRebar(col, sk, diameter=10, amount=11, offset=40, name="C1_Ties")
tie.Direction = App.Vector(0, 0, 1) # replicate along the column axis (G-14)
tie.Mark = "C1-TIE"
tie.Rounding = 4 # multiple of dia [unverified]
doc.recompute()

Seismic zones require 135°-hooked closed ties in confinement zones (seismic-design + concrete-detailing); makeRebar will not model hooks from a plain rectangle — state hooks not modelled rather than implying a complete detail.

Containment tolerance (G-15) [verified]: endpoints sitting at a host's bbox limits do NOT keep the bar inside — (1) the default 30 mm end offsets, and (2) even zeroed, a stirrup flush with a member end pokes half the bar diameter past the endpoint (4 mm for Ø8) — correct geometry, not a defect. Any bbox-containment check needs tolerance `bar_diameter/2 + margin`, or correctly-detailed end stirrups false-FAIL.

python
import math
BAR_AREA = {8: 50.3, 10: 78.5, 12: 113.1, 16: 201.1, 20: 314.2, 25: 490.9, 32: 804.2}
def check_min_steel(dia_mm, amount, width_mm, thickness_mm, rho_min):
# rho_min per concrete-detailing (min flexural / shrinkage-temp ratio for the steel
# class) — never hard-code from memory; pass it in.
as_prov = amount * math.pi * (dia_mm ** 2) / 4
as_min = rho_min * width_mm * thickness_mm
ok = as_prov >= as_min
print(f" As_prov={as_prov:.0f} mm2 As_min={as_min:.0f} mm2 -> {'PASS' if ok else 'FAIL'}")
return ok
def check_max_spacing(spacing_mm, limit_mm):
# limit_mm = min(k1*h, cap) with k1/cap per concrete-detailing.
ok = spacing_mm <= limit_mm
print(f" spacing={spacing_mm:.0f} limit={limit_mm:.0f} mm -> {'PASS' if ok else 'FAIL'}")
return ok
def check_column_rebar(b_mm, h_mm, dia_long, n_long, dia_tie, tie_spacing_mm,
rho_min, rho_max, tie_limit_mm, n_min=4):
# rho limits + tie spacing limit per concrete-detailing; the classic forms
# (1–8% ratio; min(16d_long, 48d_tie, least dim)) must be CONFIRMED there, not
# lifted from this file.
rho = n_long * math.pi * dia_long**2 / 4 / (b_mm * h_mm)
rows = [
("rho_g >= rho_min", rho >= rho_min, f"{rho*100:.2f}%"),
("rho_g <= rho_max", rho <= rho_max, f"{rho*100:.2f}%"),
(f"n_long >= {n_min}", n_long >= n_min, f"{n_long}"),
("tie spacing <= limit", tie_spacing_mm <= tie_limit_mm,
f"{tie_spacing_mm:.0f} vs {tie_limit_mm:.0f} mm"),
]
for n, ok, v in rows:
print(f" [{'PASS' if ok else 'FAIL'}] {n} {v}")
return all(r[1] for r in rows)

Audit catching a silent error (illustrative rho_min = 0.0018 placeholder — project value from concrete-detailing): 1500×1500×450 pad, per direction A_g = 675,000 mm² → A_s,min = 1215 mm²; modeled 7ר12 = 792 mm² → FAILS by 35 %; fix 7ר16 or 11ר12 at 135 mm. Run it on every rebar object — short cages are what this audit exists to catch.

python
def audit_all_rebar(doc):
"""Over every rebar object in the document. Run before every handoff."""
bad = []
for o in doc.Objects:
if getattr(o, "IfcType", None) == "Reinforcing Bar":
host = o.Host
print(f"{o.Label} host={host.Label if host else 'NONE'} "
f"dia={o.Diameter} n={o.Amount} s={o.Spacing} L={o.TotalLength}")
if host is None:
bad.append((o.Label, "no host"))
if o.OffsetStart.Value == 0 and o.OffsetEnd.Value == 0 and o.Mark == "":
bad.append((o.Label, "zero end offsets and no mark — check intent (G-15)"))
for lbl, why in bad:
print(f" [FAIL] {lbl}: {why}")
return not bad
def steel_takeoff(doc):
"""TotalLength is authoritative [verified] — use it, don't re-derive."""
total_kg = 0.0
for o in doc.Objects:
if getattr(o, "IfcType", None) == "Reinforcing Bar":
L_m = o.TotalLength.getValueAs("mm").Value / 1000.0
d = o.Diameter.getValueAs("mm").Value
kg = L_m * (d*d) / 162.0 # generic site formula: mass_per_m = d²/162 kg/m
total_kg += kg
print(f"{o.Mark or o.Label:<16} Ø{d:.0f} {L_m:7.2f} m {kg:7.1f} kg")
print(f"TOTAL STEEL (model geometry only, NO laps/hooks/wastage): {total_kg:.0f} kg")
return total_kg

This is a model quantity, not a BOQ. Laps, hooks, chairs, wastage per cost-management-din276; never hand this number over as a steel order.

3.5 Windows and doors — BIM object separate from the cut

Build the opening (void + Subtractions, §3.1) and the Arch.makeWindow/makeDoor BIM object as two separate things at the same location — this matches the bundled reference exactly (its real windows have Hosts: None yet export as valid IFCWINDOW; the void already did the cutting).

python
win = Arch.makeWindow(1150, 2100, name="Win_W1-N01") # width, height
win.IfcType = "Window" # or "Door" — same factory family, different IfcType string
win.Placement = App.Placement(App.Vector(x, y, z_sill), App.Rotation(App.Vector(0,0,1), wall_angle))

Record every opening's parameters the moment you create it — label, type, W, H, sill, wall angle, world pos, void label into a JSON store from execute_code (§6.2); corrupted openings are deleted and rebuilt, never patched (G-16/G-17).

Frame fidelity ladder: (1) plain box — acceptable schematic pass, known simplification; (2) multi-part WindowParts — the reference windows have OuterFrame, Frame, Glass, Glass panel as distinct named sub-shapes with real profiles: generate one realistic template via the GUI's Window preset picker (or insert_part_from_library, G-34) and reuse it programmatically (§2.6). A box is a pass, not the ceiling of Arch.

The two door/window placement killers [verified] — mechanics here, full rules at G-16/G-17:

  • G-16 `Normal` corruption → Null shape: a degenerate/zero Normal fails the shape

build (object present, geometry gone); patching it back to default (0,0,-1) yields a non-null but insane flat "skylight" leaf. "Not null" ≠ "geometrically sane" — verify BoundBox vs the Void_*, else delete & rebuild (§6.2).

  • G-17 `Base`-sketch `Placement` is a no-op: rotating/moving door.Base.Placement +

recompute gives an identical Shape.BoundBox — the proxy ignores it. Only the object's own `Placement` moves the built shape. Standing a flat-built door upright:

python
d.Placement = App.Placement() # 1. identity, then raw bbox
doc.recompute()
bb, H = d.Shape.BoundBox, d.Height.Value
if abs(bb.XLength - H) < 5: # 2. which local horizontal axis carries Height?
rot = App.Rotation(App.Vector(0,1,0), -90) # X -> tip up about Y
elif abs(bb.YLength - H) < 5:
rot = App.Rotation(App.Vector(1,0,0), 90) # Y -> tip up about X
else:
rot = None; print("FAIL: neither span matches Height — inspect before touching")
if rot is not None:
d.Placement = App.Placement(App.Vector(), rot); doc.recompute()
vb = doc.getObjectsByLabel("Void_D-G01")[0].Shape.BoundBox # 3. translate to void center
nc = d.Shape.BoundBox.Center
p = d.Placement
p.Base = App.Vector(vb.Center.x - nc.x, vb.Center.y - nc.y, vb.Center.z - nc.z)
d.Placement = p; doc.recompute()
# 4. verify final bbox INSIDE the void bbox (small tolerance), per axis

Never batch-apply a "best-guess" rotation from sorted span magnitudes — it can't disambiguate the two valid rotation axes and misplaces doors with similar spans (confirmed: one such batch attempt produced 10/12 wrong results, re-breaking an already-verified door). Per-object Height-axis identification, per-object verification. (Lintels over openings: §3.3.)

3.6 Stairs — the comfort envelope is not a code check

Comfort guidance (riser 140–180 mm, tread 270–340 mm, 2R + T ≈ 600–650 mm, from the bundled reference study) is an envelope, not a code check. Hard gates (max riser; min tread with/without nosing; headroom; clear width; handrail height; landing length; winder and guard rules) are owned by `stairs-vertical-circulation` (beyond-minimum access: accessibility-universal-design); this file owns that FreeCAD's stair object silently fights those gates, and that the check must be scripted and run every time.

FreeCAD's stair derivation [verified]:

RiserHeight = Height / NumberOfSteps
TreadDepth = Length / (NumberOfSteps - 1)
Nosing defaults to 0.0 mm <- the trap (G-10)

Arch.makeStairs(length=4200, width=1100, height=3000, steps=17) [verified] gives RiserHeight = 176.47 mm, TreadDepth = 262.5 mm, Nosing = 0.0:

  • Comfort 2R+T = 615.4 → "passes". Riser gate ✓. Tread gate ✗ — with Nosing = 0

the larger no-nosing minimum applies (279 mm in the reference regulation used during validation) and 262.5 < 279.

  • Fix: set Nosing = 25 (with-nosing minimum then applies, 262.5 ✓), or lengthen the

flight: Length = 280 × 16 = 4480 mm for a 280 mm tread.

To hit a target tread with fixed floor-to-floor height H: N = ceil(H / R_max) (R_max from stairs-vertical-circulation), G = T_target × (N − 1) — if the plan offers less going than G, the stair cannot be one straight legal flight; it needs a landing/dog-leg or the check fails. Say that; never silently shrink the tread.

G-19 — stairs rotation/BoundBox: makeStairs extends the flight along +X from Placement.Base; Placement.Rotation rotates about the Base point, not the flight's centre, so the flight swings off its stairwell sideways while still looking "placed". Rotate first, then correct Placement.Base until Shape.BoundBox matches the stairwell footprint — a stair whose bbox center is 1400 mm from its shaft is not "close enough" (same pivot logic for the rotated roof slab, §3.7).

Assertion script — run after every `makeStairs`. Limits are parameters; the values validated with this recipe (196 / 254 / 279 / 914 / 2032 / 3835 / 914 / 19–32 mm) are example defaults — confirm against `stairs-vertical-circulation` before any PASS:

python
def check_stair_gates(st, lim, headroom_mm=None, n_handrails=0, landing_len_mm=None):
# lim: dict(riser_max, tread_min_nosing, tread_min_no_nosing, width_min,
# headroom_min, rise_max, landing_min, nosing_min, nosing_max, comfort=(lo,hi))
R = st.RiserHeight.getValueAs("mm").Value; T = st.TreadDepth.getValueAs("mm").Value
N = st.Nosing.getValueAs("mm").Value; W = st.Width.getValueAs("mm").Value
H = st.Height.getValueAs("mm").Value
t_min = lim["tread_min_nosing"] if N > 0 else lim["tread_min_no_nosing"]
checks = [
("riser <= riser_max", R <= lim["riser_max"], f"{R:.1f}"),
(f"tread >= {t_min:.0f} mm", T >= t_min, f"{T:.1f} (nosing {N:.0f})"),
("width >= width_min", W >= lim["width_min"], f"{W:.0f}"),
("rise/landing <= rise_max", H <= lim["rise_max"], f"{H:.0f}"),
("comfort 2R+T", lim["comfort"][0] <= 2*R+T <= lim["comfort"][1], f"{2*R+T:.1f}"),
("total rise matches", abs(st.NumberOfSteps*R - H) < 1.0, ""),
("nosing within band", (lim["nosing_min"] <= N <= lim["nosing_max"]) if N > 0 else None, f"{N:.0f}"),
("headroom >= headroom_min", (headroom_mm >= lim["headroom_min"]) if headroom_mm is not None else None,
f"{headroom_mm:.0f}" if headroom_mm is not None
else "NOT MEASURED - check against slab/soffit above"),
("landing >= landing_min", (landing_len_mm >= lim["landing_min"]) if landing_len_mm is not None else None,
f"{landing_len_mm:.0f}" if landing_len_mm is not None else "NO LANDING MODELLED"),
("handrail present", n_handrails >= 1, f"{n_handrails} modelled"),
]
for name, ok, val in checks:
print(f" [{'PASS' if ok else ('----' if ok is None else 'FAIL')}] {name} {val}")
unresolved = [c[0] for c in checks if c[1] is None]
if unresolved:
print(f" UNRESOLVED (must be stated in the reply): {', '.join(unresolved)}")
return all(c[1] for c in checks if c[1] is not None), unresolved

Headroom depends on the slab/soffit above, not the stair object — measure it in the model or the §7.3 block reads NOT MEASURED, never "assumed OK" [unverified — standard OCC raycast, not round-tripped here]:

python
def measure_headroom(stair, obstructions):
"""obstructions: solids above (slabs, landings, beams). Returns min clearance mm."""
import Part
R = stair.RiserHeight.getValueAs("mm").Value; T = stair.TreadDepth.getValueAs("mm").Value
base = stair.Placement.Base; n = int(stair.NumberOfSteps); worst = float("inf")
for i in range(n):
p = App.Vector(base.x + i*T, base.y + stair.Width.Value/2, base.z + (i+1)*R)
ray = Part.makeLine(p, App.Vector(p.x, p.y, p.z + 6000))
for ob in obstructions:
for v in ob.Shape.common(ray).Vertexes:
worst = min(worst, v.Point.z - p.z)
print(f" min headroom = {worst:.0f} mm")
return worst

Stair as structural member: an RC flight is an inclined slab (cantilevered or simply-supported between landings) carrying its own considerable weight plus imposed load — a commonly under-designed element; waist ~125–175 mm [practice placeholder — sizing per `structural-analysis`]. If presented as viable: §3.8 treatment via a Part::Box proxy of the waist slab at the developed span, stated (§3.8.10). makeStairs models no handrails — absence is a code failure, not a rendering choice; list it. Flight/landing bar geometry → concrete-detailing.

3.7 Roof — structural layer first, build-up second

Model the load-bearing roof as classified structure; the layered build-up (vapour, insulation, underlay, counter-batten, covering) is roofing-waterproofing + building-physics-thermal-moisture. Either model layers as separate thin Slab solids at real thicknesses (LOIN call, §2.5) or model structure only and say so.

python
# Mono-pitch RC roof slab, 5 deg about the eave (Y) axis
roof = Arch.makeStructure(length=6200, width=9200, height=180, name="RoofSlab_R1")
roof.IfcType = "Slab"
p = App.Placement()
p.Rotation = App.Rotation(App.Vector(0, 1, 0), -5.0) # sign = falls toward -X
p.Base = App.Vector(0, 0, 6400)
roof.Placement = p
doc.recompute()
bb = roof.Shape.BoundBox # G-13: Slab centers X/Y on Base
expected_rise = 6200 * math.tan(math.radians(5)) # run * tan(alpha)
print(f"[{'PASS' if abs(bb.ZLength - (180 + expected_rise)) < 20 else 'FAIL'}] "
f"pitch rise {bb.ZLength-180:.0f} vs {expected_rise:.0f} mm")

The z-span check is verify-by-measurement made roof-specific: if the rotation pivoted at the wrong point (G-19), the BoundBox says so immediately. Parapets = IfcType="Beam" edge strips; water-tank base = Slab + the tank as a load from the §3.8.1 take-down, never an invented force. Trussed/purlin roofs: Beam/Member frames along the structural-systems load path. Roof penetrations (flues, PV ballast, drainage) are coordination events — each a Subtractions cut and a §7.4 FEM-invalidator when it hits structure.

3.8 Load derivation and FEM verification — the actual pipeline

3.8.1 Load take-down before solver — never invent a force value

Every ConstraintForce/ConstraintPressure must trace to a written take-down.

  • Load values, ULS/SLS combinations and the roof-to-soil path are owned by

`structural-analysis` (system + preliminary span/depth tables: structural-systems). Cross-check every member against `structural-systems`' preliminary sizing before treating the take-down as final — disagreement over ~15–20 % must be stated and resolved, never averaged or cherry-picked.

  • Run stress and deflection as separate analyses (ULS-type factors for stress,

service for deflection — per structural-analysis). Factored-load deflection against a span/limit ratio is meaningless; service-load stress against factored capacity is unconservative. Crossing them is common and invisible.

  • Bearing checks use unfactored service loads (geotechnics-foundations) and

include footing self-weight + overburden before PASS.

  • Screening unit weights used in validated examples (real values per

building-materials): RC ≈ 24, plain concrete 23, masonry 18–20, water 9.81, steel 77 kN/m³; residential floor imposed ~2 kPa class, roof ~0.5 kPa class — project values come from structural-analysis, not this line.

  • Gravity-only: wind and seismic are out of scope — say so. For a real occupied

building in a seismic region, actually invoke seismic-design (or confirm it ran) before calling anything "checked"; otherwise §7.3 carries its own line "lateral/ seismic: NOT evaluated — seismic-design not invoked", not a buried bullet.

w_area (kPa) -> w_line (kN/m) = w_area x tributary_width
-> F_total (kN) = w_line x span -> N = F_total x 1000

Validated-run example: RC beam 3.0 m span, 3.0 m tributary width, 150 mm slab + finishes → dead ≈ 4.80 kPa, live 1.92 kPa, factored ≈ 8.83 kPa → 26.5 kN/m → 79.5 kN. The solver calibration run itself used a deliberately lighter 21.6 kN (clean hand-check arithmetic, uncracked concrete) — substitute the real factored load for work. Build the full roof-to-soil column load table once per house (each storey's slab dead + finishes + walls + live → running axial at footing, then footing self-weight) and print it alongside any footing size stated — a size with no visible take-down is an unsupported claim even when the off-screen arithmetic was right.

Physical loadFEM constraintValue computation
UDL on beam top faceConstraintForce top faceN = w_line (N/mm) × span (mm); solver distributes over face
Area load on slabConstraintPressure top faceMPa = kPa/1000: 8.83 kPa → "0.00883 MPa"
Point load (column onto beam)ConstraintForce on partitioned face / vertexpartition first, or accept local stress artifact
Self-weightConstraintSelfWeightneeds Density on material; add whenever non-trivial
Axial on columnConstraintForce top face, Reversed=Trueservice/factored N from take-down
Soil reaction under footingConstraintPressure bottom face (upward)q_act in MPa, paired with column load on top

Pressure unit trap (G-21): 8.83 kPa = 0.00883 MPa; a bare 8.83 equals that in internal units by accident — the coincidence does not generalise. Always the string.

3.8.2 Verify face indices before binding constraints — never assume

A constraint bound to the wrong face yields a fully successful solve with meaningless numbers — the highest-severity silent failure here.

python
def dump_faces(obj):
for i, f in enumerate(obj.Shape.Faces, 1):
c = f.CenterOfMass
print("Face%-3d center=(%8.1f, %8.1f, %8.1f) area=%10.0f mm2" % (i, c.x, c.y, c.z, f.Area))
# Part::Box 3000x300x450 -> [verified]
# Face1 (0,150,225) Face2 (3000,150,225) <- ends
# Face3 (1500,0,225) Face4 (1500,300,225) <- sides
# Face5 (1500,150,0) Face6 (1500,150,450) <- bottom, top
def assert_face(obj, name, cx=None, cy=None, cz=None, tol=1.0):
idx = int(name.replace("Face", "")) - 1
c = obj.Shape.Faces[idx].CenterOfMass
for want, got, ax in ((cx, c.x, "x"), (cy, c.y, "y"), (cz, c.z, "z")):
if want is not None and abs(want - got) > tol:
raise AssertionError(f"{name} {ax}-center {got:.1f} != expected {want:.1f}")
print(f" [PASS] {name} confirmed at ({c.x:.0f},{c.y:.0f},{c.z:.0f})")

Part::Box face order is stable and confirmed empirically (G-20), but re-run dump_faces after any boolean — cuts re-index faces (G-06). Assert center+area before attaching anything.

3.8.3 What run_fem_analysis does and does not do (G-26)

run_fem_analysis(doc_name, analysis_name, timeout=..., include_screenshot=..., view_name=...) only solves an already-assembled analysis — it creates nothing except SolverCcxTools. Build first:

  1. A Part-derived solid — Part::Box proxy or Arch object (Part::FeaturePython)

directly [verified: gmsh meshed an `Arch.makeStructure` footing to 237 nodes].

  1. Fem::FemAnalysis via ObjectsFem.makeAnalysis(doc, "Name") — accepted [verified].
  2. Material — ObjectsFem.makeMaterialSolid, added to the analysis.
  3. ≥1 Fem::ConstraintFixed and ≥1 Fem::ConstraintForce/ConstraintPressure bound

to §3.8.2-verified faces, added to the analysis.

  1. Fem::FemMeshGmsh referencing the geometry, added, with the mesh actually generated.

Returns max_von_mises_MPa, min_von_mises_MPa, max_displacement_mm, node_count, working_dir, result_object. No safety factor is returned — compute it yourself (§3.8.6); any claim of a solver-reported SF is wrong for this environment.

Operational: the solve runs synchronously on the GUI thread and blocks every other call (G-28); ~3000-node members solve in seconds but a full-building mesh times out — analyse one member at a time; request timeout per budget with client ≥ 2×timeout+30 (G-33); include_screenshot=False for numeric runs; repeated runs pile up CCX_Results* — clean or read newest (G-09, §3.8.8).

What the pipeline structurally cannot tell you — state every line as not-checked in §7.3:

buckling (linear static only) punching shear cracking / tension stiffening
long-term deflection / creep reinforcement bond connection capacity
fatigue lateral / seismic wind
torsional stability soil-structure interaction settlement
construction-stage loading thermal / shrinkage restraint

3.8.4 The full working script [verified end-to-end]

python
import FreeCAD as App, ObjectsFem
from femmesh.gmshtools import GmshTools
doc = App.newDocument("BeamCheck")
beam = doc.addObject("Part::Box", "BeamProxy")
beam.Length, beam.Width, beam.Height = 3000, 300, 450 # mm
doc.recompute()
dump_faces(beam) # §3.8.2 — assert before binding
analysis = ObjectsFem.makeAnalysis(doc, "BeamCheck")
mat = ObjectsFem.makeMaterialSolid(doc, "ConcreteC30")
m = mat.Material
m['Name'] = 'Concrete-C30/37'
m['YoungsModulus'] = '30000 MPa' # §3.8.5 on choosing E
m['PoissonRatio'] = '0.20'
m['Density'] = '2400 kg/m^3'
mat.Material = m
analysis.addObject(mat)
fix = ObjectsFem.makeConstraintFixed(doc, "FixedEnd")
fix.References = [(beam, "Face1")]
analysis.addObject(fix)
frc = ObjectsFem.makeConstraintForce(doc, "FloorLoad")
frc.References = [(beam, "Face6")]
frc.Force = "21600 N" # from the take-down. ALWAYS a unit string.
frc.Reversed = True # Face6 normal is +Z, so Reversed => downward
analysis.addObject(frc)
msh = ObjectsFem.makeMeshGmsh(doc, "BeamMesh")
msh.Shape = beam
msh.CharacteristicLengthMax = "120 mm"
msh.ElementOrder = "2nd" # REQUIRED for bending accuracy (G-11)
analysis.addObject(msh)
doc.recompute()
GmshTools(msh).create_mesh()
print("nodes:", msh.FemMesh.NodeCount, "volumes:", msh.FemMesh.VolumeCount)
# -> nodes: 2713 volumes: 1334 [verified]

Then: run_fem_analysis(doc_name="BeamCheck", analysis_name="BeamCheck", include_screenshot=False, timeout=300) — actual verified return:

json
{"success": true, "max_von_mises_MPa": 3.1926, "min_von_mises_MPa": 0.00042,
"max_displacement_mm": 1.0909, "node_count": 2713,
"working_dir": "/tmp/freecad_mcp_fem_ax8l10hu"}

Constraint reference — all [verified]:

ConstraintFactoryKey properties
FixedmakeConstraintFixedReferences
ForcemakeConstraintForceForce, Direction, Reversed, References
PressuremakeConstraintPressurePressure, Reversed, Scale, References (pass "0.005 MPa")
Self-weightmakeConstraintSelfWeightGravityAcceleration, GravityDirection
DisplacementmakeConstraintDisplacementper-axis fix/free — the tool for releasing rotation at a real simple support (§3.8.7) [unverified property names]

3.8.5 Calibrate against hand calculation — mandatory, every time

An uncalibrated solver run is not evidence. Validated case (cantilever, w = 7.2 N/mm, b = 300, h = 450, L = 3000, E = 30000 MPa):

QuantityHand calculationFEMΔ
Bending stressM = wL²/2 = 32.4×10⁶ N·mm; S = bh²/6 = 10.125×10⁶ mm³; σ = 3.20 MPa3.193 MPa0.2%
Tip deflectionI = bh³/12 = 2.278×10⁹ mm⁴; δ = wL⁴/8EI = 1.067 mm1.091 mm2.3% (shear deformation)

The hand side is exactly what `structural-analysis` owns — run its method (or pull its result) first, then compare the solver against it. Closed forms for calibration (UDL w N/mm, span L mm; σ = M/S, S = bh²/6, I = bh³/12):

CaseM_maxδ_max
Cantilever, UDLwL²/2 (support)wL⁴/(8EI)
Cantilever, tip point load PPLPL³/(3EI)
Simply supported, UDLwL²/85wL⁴/(384EI)
Simply supported, midspan PPL/4PL³/(48EI)
Fixed-fixed, UDLwL²/12 support, wL²/24 midwL⁴/(384EI)
Propped cantilever, UDLwL²/8 (fixed end)wL⁴/(185EI) [unverified]

Acceptance: Δ > ~10 % means the model is wrong, not statics — wrong face, load direction, unit error, coarse mesh, or 1st-order elements (G-11). Fix before reporting.

Modulus: the run used E = 30000 MPa for C30/37; the class's secant modulus is the E_cm value concrete-detailing carries, somewhat below 30 GPa — and E directly scales deflection (≈ +17 % on the lower value). State which E was used. Deflection limits and combinations: structural-analysis; this FEM gives immediate elastic deflection only — long-term multipliers are not modeled.

3.8.6 Material presets and interpretation — where von Mises lies

MaterialE (MPa)νρ (kg/m³)Compare against
Structural steel (S275-class)210,0000.307800yield (thickness-dependent — timber-steel-design); von Mises valid
Reinforcing steel (B500-class)200,0000.307850yield per concrete-detailing
Concrete C30/37§3.8.5 (E_cm from concrete-detailing)0.202400rows below
Brick masonry3,000–8,000 [unverified]0.15–0.20~1900compression only; tension ≈ 0 — von Mises meaningless
Softwood (∥ grain)~11,000 [unverified]0.35500orthotropic — isotropic FEM a poor model
python
SF = f_yield / max_von_mises # steel only
MaterialCriterionVerdict rule
Structural steelvon Mises vs yieldSF = f_y/σ_vm; screening target per timber-steel-design; name it hand-adopted, never "solver-reported"
Concrete, tensionf_ct for the class from `concrete-detailing` (validated run recorded 3.40 MPa for C30/37 — that run's threshold, not a universal)von Mises is NOT a concrete criterion; compare max principal tensile stress to f_ct; exceedance = "it cracks", not "it fails"
Concrete, compressionservice cap per concrete-detailingscreening only
Masonry / timber—isotropic linear FEM invalid; no safety factor may be reported

Validated beam: σ_max = 3.193 MPa vs recorded f_ct = 3.40 MPa → marginally uncracked, ~6 % margin — at the real factored load (~3.7×) it would crack decisively, normal for RC and precisely why a linear-elastic uncracked FEM cannot verify an RC member: it says whether the section cracks, not whether the reinforced section is adequate afterwards.

Columns: linear static FEM gives axial stress, not buckling. Euler hand-check, reported as hand-check: P_cr = π²EI/(kL)² (k = 1.0 pinned-pinned, 0.5 fixed-fixed, 2.0 cantilever); r = √(I/A) = 0.3h for a rectangle; whether kLu/r = 33.3 (300×300, 3 m, k=1) is stocky is the braced/unbraced threshold rule in structural-analysis.

Mesh convergence: one run = one data point. Re-run at ~half CharacteristicLengthMax; peak stress moving > ~5 % → unconverged → not reportable. Fixed-support peak stress is a mesh-dependent singularity (G-24) that grows as the mesh refines — read ~1 member-depth away or label the peak a support artifact.

3.8.7 Boundary conditions — the commonest wrong-but-plausible answer

Real conditionWrong idealizationConsequenceDo instead
Simply supported beamFixed both endswL²/24 vs wL²/8 — understates bending ~3×; dangerously unconservativeConstraintDisplacement releasing rotation, or model as cantilever and accept conservatism
Beam on masonry bearingFixedoverstates restraint, understates deflectionpartial ConstraintDisplacement
Continuous beam over middle supportone span in isolationmisses hoggingmodel both spans or hand-check hogging
Column base on pad footingFixedoverstates fixity, understates swayOK for axial-only screening; never lateral
Slab on 4 wallsFixed all edgesoverstates two-way stiffnesspinned edges = conservative screen
Forces only, no fixed constraintsolver "succeeds"rigid-body motion, garbage displacements≥1 ConstraintFixed mandatory

When in doubt, choose the conservative idealization and say which one. "Modelled as a cantilever (conservative); real condition partially restrained" is honest. "The beam is fine" is not.

3.8.8 Solver troubleshooting

SymptomLikely causeFix
Prerequisite-check errormissing material/mesh/constraint/analysis membershipre-check §3.8.3 list; confirm objects in analysis.Group
Displacement in metresrigid-body motion; fixed face not restraining all 6 DOFadd/extend ConstraintFixed
nonpositive jacobian (ccx)degenerate mesh from a sliver face after a booleanchange CharacteristicLengthMax; Part::Box proxy (§3.8.10)
gmsh fails on Arch objectmany Subtractions, compound/multi-solidproxy box + state simplification
Stress 1000× expectedbare-float pressure/forceunit strings (§2.7, G-21)
Right numbers, wrong axisReversed unset / wrong Directioncheck face normal; +Z top face needs Reversed=True for downward
Deflection ~2× hand-checkElementOrder="1st""2nd" (G-11)
Timeoutmesh too fine / whole buildingone member, coarsen, only then raise timeout
2nd run = 1st run's numbersstale CCX_Results (G-09)delete old or read highest-numbered
get_rpc_status → stuckGUI thread blocked§6.1; restart; stop queueing
python
# clean result objects between runs
for o in list(doc.Objects):
if o.Name.startswith("CCX_Results") or o.Name.startswith("ResultMesh"):
doc.removeObject(o.Name)
doc.recompute()

3.8.9 The thin-member mesh cap (G-18) — the rule that saves the session

Mesh size on thin cantilevers can hang the GUI thread indefinitely, with no clean cancel [verified]: an uncapped CharacteristicLengthMax on a large thin member (a canopy-style proxy, huge face-area-to-thickness ratio) produced a mesh in the hundreds of thousands of nodes; the solve held the GUI dispatch thread past its stated timeout (get_rpc_status state:"stuck" climbing past 1000+ s) and eventually crashed the FreeCAD process, losing every unsaved change. Therefore:

  1. Generate the mesh yourself first (GmshTools(msh).create_mesh()); check

msh.FemMesh.NodeCount is low-thousands-to-tens-of-thousands before calling run_fem_analysis — never let an uncapped mesh go straight to the solver.

  1. On thin members cap CharacteristicLengthMax at a few elements across the thickness

(or shrink the analysed region), and state the idealization.

  1. If get_rpc_status shows stuck on a FEM task: stop queueing — it cannot be

safely cancelled; even doc.save() fails with "GUI dispatch unavailable" until restart (§6.1). After restart, verify object counts before assuming anything was lost — crash recovery may have preserved work; check, don't assume.

3.8.10 Proxy vs BIM object, and which members deserve a solve

Gmsh meshes Arch objects directly [verified] — prefer it: BIM object and analysed object are one object and cannot drift apart. Fall back to a Part::Box proxy for members with many Subtractions where gmsh fails/degenerates, compounds, or a deliberately conservative gross section — and say so in the reply ("checked as a 300×450 gross rectangle; two Ø100 midspan penetrations not modelled"). A quiet proxy is the FEM equivalent of a stale result. Prioritise solves (never pretend to check everything):

1. longest-span beam or slab 2. any cantilever (balcony, canopy, stair)
3. most heavily loaded column (take-down) 4. any transfer element (column on beam)
5. anything the user asked about

Everything else stays in the §7.3 "NOT verified by FEM" list. Five unverified members honestly listed beat six implied checked.

3.9 MEP risers, site/boundary, septic — coordination objects

Services engineering is owned by `building-services-tga` (riser sizing, shaft
rules, fire-stopping with fire-protection-building, penetration zoning). This file
models risers/shafts as classified solids and voids that coordinate cleanly.

MEP risers (*Steigstränge*) — vertical service solids per storey, inside a real shaft void through every slab crossed [template — not round-tripped through this bridge]:

python
riser = doc.addObject("Part::Cylinder", "Riser_Waste_DN100")
riser.Radius, riser.Height = 55, 6400 # DN100 stack incl. insulation allowance
riser.Placement = App.Placement(App.Vector(sx, sy, 0), App.Rotation())
shaft_void = doc.addObject("Part::Box", "Shaft_S1_void")
shaft_void.Length, shaft_void.Width, shaft_void.Height = 300, 250, slab_t # through-slab
shaft_void.Placement = App.Placement(App.Vector(sx-150, sy-125, slab_z), App.Rotation())
shaft_void.ViewObject.Visibility = False
slab.Subtractions = slab.Subtractions + [shaft_void]
doc.recompute() # verify by volume diff (§3.1) — every penetration is §7.4 material

Discipline: one shaft per service family (drainage, water, HVAC, electrical); every slab crossing is a Void_* with real plan position; size shafts at planning stage (retrofit core-drilling = the expensive failure mode); a duct that cannot cross a beam is a coordination fact — check BoundBox intersection before the model pours the slab.

Site and boundary — the Site container exists (§2.1); add terrain and boundary so setbacks are measurable [template]:

python
plot = doc.addObject("Part::Box", "SitePlot")
plot.Length, plot.Width, plot.Height = 12640, 9000, 100 # example plot, mm
plot.Placement = App.Placement(App.Vector(0, 0, -100), App.Rotation())
site.addObject(plot)
# boundary lines: Draft.make_line at the setback offset per edge; assert min facade
# distance by BoundBox arithmetic, PASS/FAIL print like everything else

Setback/GRZ/GFZ figures are building-regulations-permits questions; the modeling job is making them measurable from one shared project-zero origin (agreed in bim-management before first placement).

Septic / on-site wastewater (where no sewer) — model as a buried classified volume (IfcType="Footing" placeholder or labelled solid) at invert levels from building-services-tga/geotechnics-foundations. The box is a volume and position claim only — tank sizing (population equivalents, retention) must never be inferred from a drawn box; without skill numbers, call the tank schematic, unplaced.

3.10 Renovation & retrofit modeling — Bestand baseline, status tagging, delta tracking

Component-level renovation technique (what to repair, how) is owned by
`building-renovation-refurbishment` and `timber-building-renovation`; structural
condition assessment/Nachrechnung is owned by `existing-structures-retrofit`. This
file owns only the modeling pattern that emulates a renovation process on a parametric
model — never invent a repair method or a residual-strength number here.

Establishing the Bestand baseline. Two paths, both feeding the same spatial hierarchy (§2.1):

  • Survey-derived IFC exists — import it with NativeIFC (§4.2) as the Bestand document;

do not flatten it, keep the link live so corrections from a re-survey round-trip.

  • No IFC, only a paper/photo survey (the normal renovation case) — reconstruct the

Bestand manually as ordinary parametric objects (§3.1–3.9) from the Bestandsaufnahme data (building-renovation-refurbishment's survey workflow, or timber-building-renovation §Schadensanalyse for timber-specific condition mapping). A hand-reconstructed Bestand model is geometry the surveyor measured, not a design — tag it as such (§7.3 status-block vocabulary: "Bestand, as-surveyed", never "as-built verified" unless it was).

Status tagging — every object gets a renovation-phase property [template, not round-tripped through this bridge]:

python
for obj in [wall, slab, window]:
if not hasattr(obj, "Sanierungsstatus"):
obj.addProperty("App::PropertyEnumeration", "Sanierungsstatus", "Renovation",
"Phase status of this element in the renovation process")
obj.Sanierungsstatus = ["Bestand-erhalten", "Bestand-rueckbau", "Neu"]
obj.Sanierungsstatus = "Bestand-erhalten" # set per element from the survey/concept

Organize by three top-level App::DocumentObjectGroup containers — Bestand, Rueckbau, Neu — mirroring the property, not replacing it (the property survives a regroup; a Group alone does not carry the phase if an object is moved). Toggle group.ViewObject.Visibility per group to render an "as-found" view (only Bestand + Rueckbau visible), a "demolition" view (Rueckbau isolated), and an "as-built" view (Bestand-erhalten + Neu, Rueckbau hidden) from one shared document instead of three divergent files — the single-source-of-truth rule in §2.2 applies across renovation phases too.

Delta tracking — quantify what changes, don't eyeball it [template]. Same verify-by-measurement discipline as §2.4/§3.1, applied per phase:

python
# before editing a Bestand element, snapshot its volume
vol_before = wall.Shape.Volume
# ... apply the renovation edit (resize, add/subtract opening, etc.) ...
doc.recompute()
vol_after = wall.Shape.Volume
delta_mm3 = vol_after - vol_before
print(f"{wall.Label}: {delta_mm3/1e9:.3f} m³ delta "
f"({'added' if delta_mm3 > 0 else 'removed'})")

For a full Rückbau (element removed, not resized), record the pre-removal Shape.Volume on a small log object or in the FreeCAD document's Comment/a dedicated App::PropertyQuantity before deleting — once deleted, the geometry is gone and the Abbruch-volume figure (needed for building-renovation-refurbishment's Abbruch/Rückbau section and any DIN 276 cost re-take-off) cannot be recovered from the model.

Degraded-material property override for FEM. A Schadensbewertung (timber-building-renovation §5, residual cross-section/strength for decayed timber) or a historic material class (existing-structures-retrofit §4.3–4.4, reduced fck/fyk for old concrete/reinforcement) is a number computed outside this file — never re-derive it here. Apply it to the existing object's material definition before run_fem_analysis instead of creating a parallel "damaged copy" object, so the FEM input and the visible model geometry never drift apart [template]:

python
mat = FreeCAD.ActiveDocument.getObject(beam.Material.Name) if beam.Material else None
# or: assign a fresh App::MaterialObject carrying the reduced values from the
# Schadensbewertung / historic-class lookup, then point beam.Material at it
mat.Material = {**mat.Material,
"YoungsModulus": "7000 MPa", # e.g. reduced E for decay-affected timber
"CompressiveStrength": "12 MPa"}
doc.recompute() # re-run run_fem_analysis after the override — a stale result is §7.4

Log the source of the override in the object's Description property (e.g. "E reduced per Schadensbewertung §5.3, Braunfäule Klasse 2") — a reduced number with no traceable source is exactly the kind of unverified claim §7.2's honesty rule forbids presenting as a check.

LOD/LOI implications. A Bestand model is typically lower geometric fidelity, higher condition-data fidelity than a new-build model — a wall's exact thickness may carry ±20 mm survey uncertainty while its Sanierungsstatus and damage notes are precise. State this asymmetry explicitly when handing off; see bim-management for how to declare it in the LOIN.

4. IFC exchange and the bim-management handoff

4.1 The export path (and its one module trap)

python
from importers import exportIFC # NOT `import importIFC` — G-03
exportIFC.export([site], "/tmp/model.ifc")

Export the root container (site) so the hierarchy carries everything; loose element lists break the spatial tree §2.1 built. If the exporter surfaces a schema option (IFC2x3 vs IFC4 — check your build; [unverified] here), pin it explicitly so consecutive exports are comparable; the FILE_SCHEMA header line shows what you actually got.

4.2 Importing and round-tripping IFC files — NativeIFC

FreeCAD 1.0+ can hold an IFC file as its actual data structure instead of translating it into Arch objects and back (the old lossy round-trip). No MCP tool wraps this directly — drive it through execute_code (FreeCAD.openDocument(path) for a native open, or the legacy from importers import importIFC; importIFC.open(path) path for the old parametric-Arch-object conversion, §4.1's counterpart) — and confirm which mode you're in before editing, since the two behave very differently:

  • Locked mode: the whole FreeCAD document is the IFC file — every edit

writes straight back, no exportIFC call, no .FCStd. Toggled by the status-bar lock icon (BIM_ToggleNativeIFC) — GUI-only, no scripted toggle documented; if an agent needs this mode, ask the human to flip it, don't assume.

  • Unlocked mode (default): IFC "project" objects can sit alongside plain

BIM/Arch objects in one document. This is the safer default for an agent — it does not silently rewrite someone else's IFC file on every save.

  • Opening an IFC file only renders top-level objects (Site/Building) at

first — an object with no visible children may just be unexpanded, not empty; double-click (or the equivalent execute_code walk) to expand before asserting a model is missing content. Same trap-shape as §6.4's "invisible geometry" list — add this as a fourth entry when triaging.

  • Once bound into a native IFC project, an object is IFC-controlled and

loses this skill's parametric recipes (§2.2) for anything IFC doesn't model the same way — verify-by-measurement (§2.4) matters more, not less, on an imported IFC object, since you can no longer trust the FreeCAD parametric history to have produced the shape.

  • Comparing two versions of an IFC file (e.g. before/after a coordination

round-trip, or two exports of the same model): Utils → IFC Diff (BIM_Diff) diffs by IFC GlobalId — red/removed, green/added, yellow/ geometry-changed, orange/properties-changed. Also GUI-only; for a scripted check, fall back to §4.4's grep/count discipline on both files.

  • Legacy (non-native) import still exists and is what most non-1.0-workflow

guidance elsewhere assumes: importIFC.open() with an import-mode preference (full parametric Arch objects / non-parametric Arch objects / Part shapes only / one shape per floor) trading fidelity for load speed on large files — pick full-parametric only when you actually intend to edit what comes in.

4.3 Pre-export validation — BIM Preflight (run before every export)

FreeCAD ships a built-in checker for exactly this handoff: Manage → Preflight checks… (BIM_Preflight, GUI-only — no MCP tool wraps it, so either drive it by hand or call the underlying Python checks via execute_code if scripting access is needed). Run Test All before every export that leaves this session; it catches classes of error grep can't:

  • Project hierarchy — at least one Site→Building→Storey chain exists and

every object sits inside a storey (this is the automated form of §2.1's hierarchy discipline — run it, don't just eyeball the tree).

  • Undefined objects — plain Part/Draft shapes with no BIM type will

export with no properties; this is the automated check for the "one source shape... carries no BIM classification" trap flagged at §2.1.

  • Solids — invalid/open geometry per object.
  • Explicit quantities — objects with Length/Width/Height not flagged for

IFC export (Manage → Manage IFC quantities…, BIM_IfcQuantities); a quantity can silently read zero downstream even though the geometry is correct — this is a distinct failure mode from the volume-verification in §2.4, because it checks the exported quantity claim, not the modelled shape.

  • Common Psets present and complete — e.g. Pset_WallCommon,

Pset_DoorCommon attached and matching the schema (edit via Manage → Manage IFC properties…, BIM_IfcProperties; custom Psets live in $USERAPPDATA/BIM/CustomPsets.csv).

  • Materials assigned to every BIM object.
  • Standard codes — classification (Uniclass/Omniclass/etc, via **Manage →

Manage classification…**, BIM_Classification) present; this is a formal standard-code slot, distinct from this skill's own IfcType/naming convention (§2.3) — populate both, they answer different questions (IfcType = what it is to the IFC schema; classification code = what it is to the client's cost/FM taxonomy).

  • Compatibility quirks worth knowing before a client opens the file in

Revit: extrusion-only geometry, "standard case" walls/structural elements, no line segments under 1/32", IfcRectangleProfileDef export disabled.

Preflight is advisory (failures don't block export) and does not replace §4.4's export-and-grep discipline — it catches structural/organizational problems before export; §4.4 proves the specific claims this skill made about an object actually round-tripped. Run both.

Preflight and §4.4 are both author-side and both partial. The machine-side proof of the exported file — STEP syntax, EXPRESS schema, buildingSMART normative rules, and the project's IDS information requirements — belongs to ifc-model-validation, together with the gates that decide whether an export may be delivered and the finding→repair mapping for what comes back red. For generated models that check chain is not optional: the failures it catches (missing storey containment, invalid GUIDs, proxy classes, zero quantities, empty Psets, degenerate faces) are exactly the ones that never show up in a viewer.

4.4 Verify classification by parsing, not by trusting properties

grep -c IFCWINDOW /tmp/model.ifc
grep -c IFCDOOR /tmp/model.ifc
grep -c IFCFOOTING /tmp/model.ifc
grep -c IFCREINFORCINGBAR /tmp/model.ifc

obj.IfcType == "Window" alone is a claim; the round-trip is the measurement — same discipline as the volume diff: an export is an instrument.

4.5 Handoff to bim-management

ItemThis skill guaranteesbim-management owns
Spatial treeSite→Building→Storey, real elevations, elements containeddecomposition vs. project naming/Pset scheme (ISO 19650 flow; AIA/BAP)
Classificationcorrect IfcType, proven by grep (§4.4)MVD/view fit (Reference vs Design Transfer), model-checker rules
Geometryparametric, volume-verified, LOIN-appropriate (§2.5)exchange format, Data Drops, coordinate/zero-point standard
SemanticsFEM verification stamped on objects (§7.5)property sets, classification codes, FM information
Open items§7.3 status block lists all unverified/unmodelled workissue tracking (BCF-style), coordination, conflict resolution
Proof of the exportPreflight (§4.3) + grep round-trip (§4.4), author-side— machine validation of the file itself is ifc-model-validation (syntax/schema/normative rules/IDS)

The DACH process frame (details in bim-management): AIA (Auftraggeber-Informationsanforderungen ≈ EIR) and BAP (BIM-Abwicklungsplan ≈ BEP) define what the exchange carries; LOIN (DIN EN 17412) defines how much — §2.5 is the modeling-side application. Do not duplicate process here.

5. GOTCHAS — the complete master list

FreeCAD-API rows validated on 1.0.1 through this bridge (mechanics in §3); MCP rows are behavioural facts of the neka-nat/freecad-mcp queue/timeout design. Each fails quietly or misleadingly; §3/§6 reference these IDs.

IDGotchaWrong → Right
G-01name= on Arch factories sets Label, not Namedoc.PadFooting AttributeError → doc.getObjectsByLabel("PadFooting")[0]
G-02Sketch attachment renamed in 1.0sk.Support = (obj,["Face5"]) → sk.AttachmentSupport = [(obj,"Face5")]; sk.MapMode = "FlatFace"
G-03IFC exporter module pathimport importIFC → from importers import exportIFC
G-04Quantities read back in internal units (mm, kg, s)raw fc.Force prints 21600000.0 mm*kg/s^2 → assign "21600 N", read .getValueAs("N")
G-05makeRebar doesn't populate host.Armatures when scriptedfooting.Armatures == [] → check rebar.Host [verified]
G-06Face indices assumed, any boolean re-indexes faceshard-coded "Face1" after a cut → enumerate+assert by CenterOfMass (§3.8.2)
G-07window.Hosts = [wall] does not cut the wallgeometry relies on it → wall.Subtractions void solid (§3.1)
G-08Missing doc.recompute()stale Shape.Volume read → recompute, then read
G-09Repeated FEM runs accumulate CCX_Results, CCX_Results001…reading old results → delete between runs or read newest (§3.8.8)
G-10makeStairs defaults Nosing = 0.0assuming with-nosing tread minimum → zero nosing raises the minimum to the no-nosing value (§3.6) [verified]
G-11FEM ElementOrder"1st" tets far too stiff/inaccurate in bending (~2× deflection) → "2nd" required [verified]
G-12makeFloor.Elevation looks directly settablefloor.Elevation = "-1200 mm" silently reverts to 0 on recompute — derived from `Placement.Base.z` → p = floor.Placement; p.Base.z = -1200; floor.Placement = p [verified]
G-13makeStructure centering depends on IfcTypeassuming corner-based Placement.Base: [verified 1.0.1] Column/Slab → X,Y centered, Z corner (+H up); Beam/Footing → X corner (+L), Y,Z centered. Lintel lands 75 mm low for a 150 mm depth; slab footprint shifts half its size → world-coordinate voids cut 0.000 m³ silently. Print `Shape.BoundBox` right after every Placement set and compare
G-14makeRebar.Direction defaults (0,0,0)trusting Spacing: 51 bars/offset 75 on a 10287 mm strip → Spacing=3 mm (spread over 2·offset); set Direction to the replication axis → 202.7 mm as intended; verify Spacing ≈ L/(n−1) [verified]
G-15Rebar end-offset defaults + bar protrusion break naive containmentflat few-mm bbox fudge false-FAILs end stirrups: OffsetStart/OffsetEnd default 30 mm (zero unless modeling laps); flush stirrup pokes ½·bar dia past the endpoint (4 mm for Ø8) — correct geometry; tolerance must be `bar_dia/2 + margin` [verified]
G-16Window/Door Normal corruption → Null shapepatching Normal to default (0,0,-1) gives non-null but flat, skylight-oriented geometry; null ≠ sane — delete & rebuild from saved params, verify BoundBox vs Void_* (§3.5/§6.2) [verified]
G-17Door/Window Base-sketch Placement has zero effect on built shaperotating/repositioning door.Base.Placement → identical BoundBox silently; only the object's own `Placement` transforms; upright-fix procedure §3.5; never batch-guess rotations from sorted spans — 10/12 wrong in one confirmed attempt [verified]
G-18Thin member + uncapped mesh kills the sessionletting the solver generate a giant mesh: hundreds of thousands of nodes → GUI stuck 1000+ s past timeout → crash, unsavable; mesh yourself, gate on NodeCount (§3.8.9) [verified]
G-19Placement rotation pivots at Placement.Base, not element centreassuming rotate-in-place for stairs/roof — flight/roof swings sideways off target; set rotation first, correct Base, verify BoundBox (§3.6/§3.7)
G-20Part::Box face order stable (verified): F1 x=0, F2 x=L, F3 y=0, F4 y=W, F5 bottom z=0, F6 top z=Hassuming it survives a boolean → re-dump after any cut (G-06)
G-21Pressure as bare float can be right by accident8.83 for 8.83 kPa equals 0.00883 MPa internally — coincidence, never generalises → always the unit string
G-22execute_code budget: 90 s queue + 90 s exec; client socket 210 smonolithic 10-minute scripts → split into per-element calls (§1.4)
G-23Long ops block the whole GUI thread (saves included)heavy boolean/solve inside execute_code → execute_code_async + commit(fn, timeout=120) (§1.4)
G-24Fixed-support peak stress is a mesh-dependent singularityreporting it as design stress → read ~1 member-depth away or label as artifact (§3.8.6)
G-25`GUI_DISPATCH_STUCK` / get_rpc_status → stuckqueueing more calls → stop; stuck task uncancelable; restart per §6.1
G-26run_fem_analysis only solves assembled analyses; returns no safety factorexpecting it to wire materials/BCs/meshes → build the 5 prerequisites (§3.8.3); compute SF vs the owning skill's criterion
G-27execute_code namespace persistent (FreeCAD/App/Gui pre-aliased) and dirty after errorsrelying on leftovers → keep calls self-contained; inspect leftovers after failures (§6.2)
G-28GUI dispatch is FIFO, one operation at a timeparallel MCP fan-out around a solve → serialize everything
G-29Dev/nightly: execute_code exception can leave FeaturePython objects with broken Proxymutating them → inspect obj.Proxy/delete first (§6.2)
G-30Screenshots on by default — the token hogdefault-on everywhere → include_screenshot=False for analytical calls, correct view_name, --only-text-feedback for long builds (§1.3)
G-31No headless: Xvfb hangs the GUI thread foreverxvfb-run FreeCAD → live GUI on a real display (§1.1)
G-32RPC localhost-only by default"the port is open, right?" → Remote Connections + Allowed IPs (CIDR) + --host — an explicit user decision (§1.5)
G-33run_fem_analysis client socket must be ≥ 2×timeout + 30 sclient cutting mid-queue → size the socket ceiling from the requested timeout (§1.4)
G-34insert_part_from_library supplies prepared templates (windows/doors)rebuilding multi-part frames per project → one template, many instances (§2.6, §3.5)
G-35create_object/edit_object are single-property CRUDassembling sketch-attached cages through them → parametric chains belong in execute_code

6. Error recovery playbook

6.1 GUI_DISPATCH_STUCK / state: "stuck"

  1. Stop queueing — every new call stacks behind the blocker and times out at the

client (G-28); more damage, zero information.

  1. get_rpc_status — confirm state and how long it has been stuck.
  2. If a run_fem_analysis/mesh run: G-18's worst case applies — the task **cannot be

cancelled** and even doc.save() fails until the process restarts.

  1. Human restarts FreeCAD; crash recovery may have preserved unsaved work — **verify

(§6.6) before assuming anything in either direction**.

  1. Re-run §1.6 preflight; resume from the last verified checkpoint — which is exactly why

§2.4 verifies incrementally and §1.7 saves after each. Prevention dominates anyway: short calls (G-22), async for heavy work (G-23), node-count gate before every solve (§3.8.9).

6.2 Null shapes / corrupted Window/Door — delete & rebuild from saved params

Symptoms: obj.Shape null/isNull; BoundBox spans inconsistent with Width/Height; object present, geometry gone (after touching Normal, or an exception left a broken Proxy — G-16, G-29). Do not patch; rebuild — only possible if creation stored params:

python
import json
PARAM_STORE = "/tmp/opening_params.json" # written at creation time
def save_opening_params(obj, void, w, h, sill, wall_angle, world):
try: store = json.load(open(PARAM_STORE))
except Exception: store = {}
store[obj.Label] = dict(type=obj.IfcType, W=w, H=h, sill=sill,
angle=wall_angle, world=list(world), void=void.Label)
json.dump(store, open(PARAM_STORE, "w"), indent=1)
print(f"[PASS] params stored for {obj.Label}")

Rebuild order: remove the corrupted BIM object and its Void_* from Subtractions → doc.removeObject(...) → recompute → rebuild void → re-cut → volume diff (§3.1) → rebuild BIM object at saved placement → verify BoundBox inside the void (§3.5). Delete any half-built FeaturePython with a broken Proxy too — stale proxies poison later label fetches.

6.3 Recompute loops / stuck-touched objects

doc.recompute() keeps failing; objects stay ['Invalid','Touched'].

  1. Identify: [o for o in doc.Objects if "Invalid" in o.State or "Touched" in o.State].
  2. Usual causes: Base/Subtractions link to a deleted object; a sketch whose

AttachmentSupport face vanished in a boolean (G-06); a null-profile void.

  1. Clear broken links (obj.Subtractions = [v for v in obj.Subtractions if v in doc.Objects]),

re-attach sketches to surviving faces, recompute; if one object poisons the document, delete & rebuild from params (§6.2) beats archaeology.

6.4 Misplaced or "invisible" geometry — the four classic lies

  • Cut did nothing (0.000 m³): almost always the G-13 footprint shift — void is real,

slab sits half its size away. Print both BoundBoxes, fix Placement, re-verify.

  • Stress/force 1000× wrong: bare-float unit bug (G-04/G-21) — audit every numeric

assignment to Force/Pressure/E; make them strings.

  • "I rotated it and nothing moved": you edited a Base sketch Placement (G-17) or

patched a Normal (G-16). Own-Placement only.

  • "This imported IFC object has no children/looks empty": a freshly opened or

imported native-IFC file only renders top-level objects by default (§4.2) — expand (double-click, or the scripted equivalent) before concluding content is missing.

6.5 Stale FEM results

Repeated runs leave CCX_Results*; reading the wrong one returns old numbers under a fresh call. Delete old result objects between runs (§3.8.8) or read the highest-numbered, and stamp results onto members (§7.5) so a stale number betrays itself by geometry fingerprint even if cleanup is forgotten.

6.6 Post-restart verification protocol

python
print(App.Version())
doc = App.ActiveDocument
print("objects:", len(doc.Objects)) # vs your last checkpoint note
for lbl in ("Wall_W-N-01", "PadFooting_F1", "Win_W1-N01"):
o = doc.getObjectsByLabel(lbl)
ok = o and o[0].Shape and not o[0].Shape.isNull()
print(lbl, "->", "MISSING" if not o else ("NULL SHAPE" if not ok else o[0].Shape.BoundBox))

Every MISSING/NULL SHAPE is a §6.2 case; then re-run fem_ledger(doc) (§7.5) — crash + recovery is when stamped-but-stale verification lies.

7. Agent workflow — brief → plan → model → verify → document

7.1 The loop

0. BRIEF building type, storeys, use, location/standard, deliverable level
(massing? model? engineer-ready?). A missing design value is a signal a
sibling skill must run first — never a licence to guess.
1. PLAN building-planning-spatial (program) + building-typology (form) +
structural-systems (system, preliminary sizes) BEFORE any geometry;
real projects additionally: geotechnics-foundations, concrete-detailing,
structural-analysis, stairs-vertical-circulation, seismic-design.
2. SKELETON §1.6 preflight → Site/Building/Storey hierarchy, real elevations (§2.1)
→ grid/axis reference → doc.save().
3. MODEL one element type per increment (walls → openings → slabs → structure →
rebar → stairs → roof → risers → site), one short execute_code call each
(G-22), doc.save() after every verified increment.
4. VERIFY BoundBox vs intent (G-13/G-19) → volume diff per cut (§3.1) → PASS/FAIL
prints → stair/rebar/column audits → fem_ledger (§7.5). An increment
without a printed PASS line did not happen.
5. SOLVE what you claim: §3.8, prioritised §3.8.10, hand-check ≤ ~10 % (§3.8.5),
convergence, stamped (§7.5).
6. EXPORT §4: IFC export + grep; fix classification before calling it done.
7. DOCUMENT §7.3 status block **from fem_ledger output**, §7.2 vocabulary, open items
routed to owning skills.

7.2 The honesty rule and the vocabulary

**Any element presented as structurally adequate must carry solver output. Any element
without it must be flagged as unverified, in the reply, unprompted.**
  1. Absence of a check is information the user needs — it degrades with every

unflagged reply; re-state on every substantive model reply, not only the first.

  1. A passing FEM run is not a passing design — name criterion, load case, margin;

never the word "safe". 3. Silence is a claim — showing columns and footings without "unverified" asserts by omission that they are fine.

Never saySay instead
"the beam is fine / safe / adequate""FEM: σ_vm 3.19 MPa vs f_ct 3.40 MPa — uncracked, 6 % margin, under the stated load; not an RC design check"
"the footing is sized correctly""sized for an assumed 150 kPa bearing; needs geotech confirmation + punching check"
"structural model complete""geometry complete; FEM run on 1 of 6 members; 5 unverified"
"code-compliant stair""passes the riser/tread/width gates supplied by stairs-vertical-circulation; headroom not measured; handrails not modelled"
"the column is adequate""axial stress X MPa under the §3.8.1 take-down; buckling hand-checked only (kL/r = 33); no lateral case run"
"rebar is designed""cage modelled and checked against minimum-steel values passed from concrete-detailing; development lengths, laps, hooks not detailed"
"the model is verified""geometry verified by volume diff and IFC export; structure verified only where listed below"
"this is ready to build"never — see the Reality Check

7.3 The mandatory status block

Include whenever the model contains structural elements — do not omit it because the user did not ask:

STRUCTURAL VERIFICATION STATUS
Verified by FEM (CalculiX): <member: sigma_vm, delta, load case, criterion compared,
mesh + convergence delta, hand-check delta>
NOT verified by FEM: <every other structural member>
Hand-checked only: <member: formula, result>
Assumed inputs: <soil bearing, concrete class, E, loads, boundary
idealization, which combination>
Simplifications: <proxy solids, omitted penetrations, single-span models>
Not modelled at all: <plinth beams, lintels, handrails, hooks/laps, ...>
Not checked at all: punching shear, one-way shear, wind, torsion, buckling,
connections, long-term deflection, cracking, settlement,
construction-stage loading
Lateral / seismic: NOT evaluated in this skill — seismic-design
<invoked: yes/no; if no, say so explicitly, don't bury
it — for a seismic-region building this is a real gap>
Cross-check vs preliminary sizing: <structural-systems consulted? agree within
~15-20%? if not run, say so>
=> NOT construction-ready. Requires a licensed structural engineer (Tragwerksplaner /
equivalent) and building-authority approval (Baugenehmigung incl. bautechnischer
Nachweis where applicable).

If zero members have been through the solver, lead with "FEM NOT RUN — no member in this model has been structurally verified." — before describing the model at all.

7.4 What silently invalidates a previously-run FEM

Re-run, or downgrade to unverified, whenever any of these change: member dimensions; Subtractions added/removed (new penetration or opening); material properties (class, E, ν, density); load values, tributary width, or combination; boundary conditions or face bindings (including face re-indexing after a boolean); span, support locations, or an added/removed intermediate support; mesh density or element order; the proxy drifting from the BIM object it stands in for. A stale FEM result on an edited member is worse than no result, because it looks like evidence.

7.5 Machine-enforce the ledger — don't rely on memory

python
def stamp_fem(obj, sigma_mpa, delta_mm, load_case, criterion, nodes, hand_delta_pct):
if not hasattr(obj, "FEMStatus"):
obj.addProperty("App::PropertyString", "FEMStatus", "Verification", "FEM record")
obj.addProperty("App::PropertyString", "FEMStamp", "Verification", "geom fingerprint at run")
obj.FEMStatus = (f"VERIFIED sigma={sigma_mpa:.3f}MPa delta={delta_mm:.3f}mm "
f"case={load_case} vs {criterion} nodes={nodes} hand_delta={hand_delta_pct:.1f}%")
obj.FEMStamp = geom_fingerprint(obj)
def geom_fingerprint(obj):
s = obj.Shape
return f"{s.Volume:.3f}|{len(s.Faces)}|{len(obj.Subtractions) if hasattr(obj,'Subtractions') else 0}"
def fem_ledger(doc):
"""Print §7.3's first lines straight from the model. Run before every handoff."""
structural = {"Footing","Column","Beam","Slab","Pile","Member","Stair"}
verified, unverified, stale = [], [], []
for o in doc.Objects:
if getattr(o, "IfcType", None) in structural:
st = getattr(o, "FEMStatus", "")
if not st:
unverified.append(o.Label)
elif getattr(o, "FEMStamp", "") != geom_fingerprint(o):
stale.append(o.Label) # geometry changed since the run
else:
verified.append(f"{o.Label}: {st}")
print("VERIFIED BY FEM: " + ("; ".join(verified) or "NONE — FEM NOT RUN"))
print("STALE (re-run): " + (", ".join(stale) or "none"))
print("NOT VERIFIED: " + (", ".join(unverified) or "none"))
return verified, stale, unverified

Run fem_ledger(doc) immediately before any reply that describes the model and copy its output into §7.3 — reconstruction from memory is where unverified members quietly become verified ones.

7.6 Worked example — a bad reply and a good one

Bad (defensible in parts, false as a whole):

Here's your G+1 house model. The structure uses 300×300 columns on 1500×1500 pad
footings with a 150 mm slab, and the FEM analysis came back at 3.19 MPa, well within
limits. The stair is code-compliant at 176 mm risers. Ready for your contractor.

Good:

Not construction-ready — a modeling and screening exercise; needs a licensed
structural engineer plus building-authority approval before anyone builds from it.
Model: G+1; Site → Building → 5 storeys (incl. Foundation at −1200); 22 walls, all
openings parametric and volume-verified; IFC export confirms
IFCFOOTING/IFCWINDOW/IFCREINFORCINGBAR.
```
STRUCTURAL VERIFICATION STATUS
Verified by FEM: Beam B1 (3.0 m) — sigma_vm 3.193 MPa vs f_ct 3.40 MPa (C30/37),
delta 1.09 mm vs L/360 = 8.3 mm, case per §3.8.1 take-down,
2713 nodes 2nd-order, hand-check delta 0.2%/2.3%.
Modelled as CANTILEVER (conservative); real condition partially
restrained. Mesh convergence NOT yet re-run.
NOT verified: Columns C1-C6, footings F1-F6, slabs S1-S2, stair flight
Hand-checked: C1 slenderness kL/r = 33 (stocky limit per structural-analysis?)
Assumed: soil 150 kPa (NO GEOTECH), C30/37, E 30,000 MPa (skill value is
lower — deflection scales with E; concrete-detailing)
Not modelled: plinth beams, lintels, handrails, rebar hooks/laps
Not checked: punching shear, wind, buckling, cracking, settlement
Lateral/seismic: NOT evaluated — seismic-design not invoked; building sits in a
seismic region, this is a real gap
Cross-check: preliminary sizing NOT checked against structural-systems for B1
```
Stair: riser 176.5 ✓, tread 262.5 with 25 nosing ✓, width 1100 ✓ — but **headroom not
measured, no handrails modelled**.
Biggest open item: footings sized on an assumed bearing pressure — get a geotech
report before that number means anything.

8. Known gaps in this skill — state these when relevant

  1. Design values are placeholders by policy. Every numeric limit this file needs

(min steel, cover, bearing, stair gates, combinations) is passed in from its owning skill; defaults in check functions are validation-era examples, never code.

  1. Unverified patterns: closed-sketch stirrups (§3.4); ConstraintDisplacement

property names (§3.8.7); headroom raycast (§3.6); Arch.makeVoid, insert_part_from_library templates, §3.9 riser/site/septic blocks, §4.2's NativeIFC open/import and lock-mode behaviour, and the async commit(fn, timeout=120) pattern — directionally correct, not yet round-tripped through this bridge; verify before shipping into a live deliverable.

  1. No mesh-convergence second data point was ever taken on the validated beam —

§3.8.6 protocol is right, the re-run wasn't; any claim about that beam is single-mesh.

  1. No two-way slab, raft, pile or lateral workflow exists here at all —

engineer-only in the current state.

  1. IFC validation is grep plus an unwrapped GUI tool — §4.4 proves entity

presence and count; §4.3 (BIM Preflight) covers hierarchy/Psets/materials/ classification/compatibility if someone runs it, but no MCP tool wraps it, so an agent working headless can't enforce it, only recommend it. Relational integrity of the exported file (does the Pset content match, do IFC relationships resolve) beyond what Preflight's own tests cover is still unchecked; schema-option exposure [unverified].

  1. Lateral/seismic is a named gap, not a solved handoff — nothing confirms

seismic-design ran or agrees with the gravity-only sizing here; close it by invoking the skill, not by citing its name.

  1. **The §3.8.1 load path is not shown reconciled against structural-systems on a

worked example** — treat any disagreement as something to resolve, not to average.

Which skill owns what — defer rather than duplicate:

TopicOwner skill
Soil investigation, bearing capacity, settlement, retaining, drainagegeotechnics-foundations
Cover, min/max steel, anchorage, laps, hooks, BBS, confinement detailingconcrete-detailing
System choice, preliminary member sizing tables, load-path narrativestructural-systems
Load combinations, internal forces, deflection/stability checksstructural-analysis
Earthquake action, regularity, ductile detailingseismic-design
Masonry / timber / steel member & connection rulesmasonry-construction, timber-steel-design
Room sizes, circulation, plan layoutbuilding-planning-spatial
Stair/walk code gatesstairs-vertical-circulation
Bylaws, setbacks, permit workflow, structural submissionbuilding-regulations-permits
Accessible stairs/ramps beyond minimumsaccessibility-universal-design
Quantities, cost groups, BOQ disciplinecost-management-din276
Service sizing, riser/shaft engineering, penetration zoningbuilding-services-tga
Build-ups, U-values, acoustics, fire classesbuilding-physics-thermal-moisture, building-acoustics, fire-protection-building
Window/door design, lintel detailingopenings-windows-doors
BIM process, naming, MVD, CDE, model checkingbim-management
This skillMaking all of the above real, parametric and solver-checked inside FreeCAD via the MCP bridge — and refusing to overstate the result

When a recipe raises a design question, stop modeling and open the owning skill — the model is the argument's evidence, never the argument itself.

All versions