Load-bearing and enclosing masonry design and detailing per DIN EN 1996-1-1/-2/-3 (Eurocode 6) with the German National Annex: masonry unit groups (Hochlochziegel HLz, Vollziegel, Kalksandstein KS, Porenbeton PB, Leicht-/Normalbeton LB/NB) with gross sizes, density classes (RDK) and the fmk characteristic-compression-strength grids per unit group x mortar group; mortar groups (Normalmörtel M2.5-M20, Dünnbettmörtel DM, Leichtmörtel LM21/36); ULS design by the simplified method (centered and ecce…
Install
npx vskill@latest install felixkarevo/construction-skills/masonry-constructionSKILL.md
Masonry Construction (Mauerwerksbau) — EN 1996 + German NA
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
This skill turns "an masonry wall" into an actual design aid: which unit group, which mortar group, what characteristic masonry strength fmk follows from the pair, what the wall may be asked to carry under the simplified method, how shear resistance and bracing are built up, which wall typology and which detailing rules apply, and what has to be true on site before the next trade covers it. It covers DACH/Eurocode practice: metric unit formats, DIN EN 1996 with the German National Annex (NA), EN 771 product families, EN 998 mortars, DIN 4172 dimensional coordination.
Masonry carries the gravity load, the wind, the earth pressure and — if the building is braced by it — the seismic force, through the same wall that must simultaneously keep out rain, carry plaster, insulate and satisfy fire and sound requirements. Every decision here is therefore a materials decision, a structural decision and a physics decision at once. This file keeps the numeric grids together so that a specification, a calculation note or a FreeCAD model uses real fmk values, real effective-height rules and real detailing limits instead of plausible-sounding numbers invented on the spot.
Every numeric value is tagged with its source digest as [VERIFY] where it was OCR-degraded in the underlying tabular handbook and must be read from the primary standard before being quoted in a submission. Values that are trade practice rather than a code clause are labelled [practice]. Values computed from the digest data are labelled [derived].
Reality Check — Liability and Approval
This skill produces design aids and calculation guidance for planning and FreeCAD/BIM modelling ONLY.
- Nothing in this file is a structural design. Load-bearing masonry, shear-wall
design, cellar-wall design and any masonry carrying a slab or roof are design decisions reserved to a qualified engineer (Tragwerksplaner; in Germany statically relevant masonry in the regular procedure is checked by a Prüfingenieur, and masonry outside the simplified/native rules generally needs an approved type or expert review, allgemeine bauartgenehmigung / Zustimmung im Einzelfall).
- **The design MUST pass the local building authority (Baugenehmigung) before
construction**, with the Bundesland building code (MBO/LBO) and the linked technical building rules (TVV, Bauregellisten) applying locally.
- Never present a FreeCAD wall object, an fmk value or a calculation aid in this
file as construction-ready. A wall modelled at 240 mm is geometry, not a verification.
- If the user starts treating output as final — orders material, says the
Maurerkolonne starts Monday, asks whether a wall "can take" the slab — stop and state plainly that a licensed engineer must run and stamp the analysis and that authority approval is required.
- Never fabricate a test certificate, CE/DoP declaration, factory-production-control
document, mortar-group classification or approval reference.
- Masonry in seismic regions (Germany seismic zones 0-3 per DIN EN 1998-1/NA,
ÖNORM B 1996-1-1 Annex, Swiss SIA 261/5) is out of scope for a design aid — see §11 and route to the seismic-design skill.
Section 0: Scope, and Which Sibling Skill Owns What
| Question | Owned by | |
|---|---|---|
| Seismic zone, ductility class, confinement elements, wall-density and diaphragm rules for EC8 | seismic-design | |
| Concrete grade, reinforcement, ring beam / Ringanker bar schedules, padstones, precast lintel design | concrete-detailing | |
| Rising damp, waterproofing build-ups (Frisch-, Schwarz-, Weißesperrschicht), Kellerabdichtung systems | waterproofing | |
| U-values, hygrothermal verification (GLASER / WUFI), DIN 4109 acoustic design in detail | building-physics-thermal-moisture | |
| Quantities, unit counts and rates for a cost plan (DIN 276 KG 300) | cost-management-din276 | |
| Site logistics, wall-build sequences, curing durations in a programme | construction-scheduling-site | |
| Bearing capacity, sulphate attack on foundation masonry, Kellerwannen variants | geotechnics |
This skill owns: the masonry unit and its classification, the mortar groups, the fmk grids, the EC6/NA design rules (compression, shear, local bearing, effective height, slenderness), the wall typologies (single-leaf, two-leaf, cavity rules, WDVS), the masonry-side detailing (bond, joints, ring beam, lintels, ties, movement joints, plinth), the masonry physical properties, execution tolerances and labour figures, the defect catalogue. Where a numeric conflict appears with a sibling, the owner wins and this file is corrected.
Section 1: Which Standard Governs What
| Topic | Standard | Used here for | |
|---|---|---|---|
| Masonry design (design of unreinforced, reinforced, confined masonry) | DIN EN 1996-1-1 + National Annex DIN EN 1996-1-1/NA | fmk via k/alpha/beta grids, gammaM, effective-height and reduction-factor rules, shear, local compression, slenderness limits | |
| Masonry — seismic design | DIN EN 1996-1-1/NA §3.2 + DIN EN 1998 | routed to seismic-design (§11) | |
| Masonry — simplified calculation method | DIN EN 1996-3 + NA | cellar walls without calculation, low-rise wall design, applicability tables | |
| Masonry — fire design | DIN EN 1996-1-2 | EI/REI thickness tables (§12.4) | |
| Masonry units (product) | EN 771-1 (clay, + DIN 105-100 / DIN EN 105 forms), EN 771-2 (lime-sandstone KS, + DIN V 106), EN 771-3 (aggregate concrete LB/NB, + DIN EN 771-3 + DIN V 18151-153), EN 771-4 (AAC PB, + DIN EN 771-4 + DIN V 20000-404), DIN 20000-401..404 application standards | unit groups, declaration of compressive strength fb, density class RDK, gross dimensions | |
| Masonry mortars | EN 998-2 + DIN V 18580 / DIN EN 19918 series (Werkmörtel), DIN EN 998-1 (render mortar) | mortar groups M/DM/LM, declared fm, downgrade rule when CE marking lacks extra properties | |
| Dimensional coordination | DIN 4172 (building grid, BM 12.5 cm), DIN 323 series R5/R10/R20 small sizes | Richtmass/Nennmass, wall nominal thicknesses | |
| Vapour/physical properties | DIN 4108-4 (design-value catalogue), EN ISO 1046/EN 1745 | lambda, mu, cp values used in §12 | |
| Sound insulation | DIN 4109-33 (design values catalogue, mass-law curves, two-leaf formulas) | Rw estimates, partition masses (§12.3) | |
| Fire (national classification route) | DIN 4102-4 (Baustoffklasse tabulated wall data); EC6 route per DIN EN 1996-1-2/NA | wall thickness for EI/REI (§12.4) | |
| Render/plaster | EN 998-1, DIN 18550 groups, DIN EN 13914 (application), DIN 18550-2 quality levels Q1-Q4 | plaster spec (§10.9) | |
| Works contract / execution | VOB/C ATV DIN 18330 (Mauerarbeiten), DIN 18202 (tolerances Table 3), DIN 18203 (execution of masonry — not digested, see §13.4) | execution rules, tolerances | |
| Actions | DIN EN 1990/1991-1-1/-1-3/-1-4 + NA | gammaG 1.35 / gammaQ 1.5, partition surcharge, wind, snow (§5.1) |
Honesty note on the digest basis: the numeric grids below were taken from a tabular-handbook extraction whose text layer lost some superscripts and cell pairings. Every table that is partially degraded carries a [VERIFY] flag; read the actual NA table before putting the number in a statics submission. DIN 18202/18203 tolerance tables were NOT present in the digests (§13.4).
Section 2: Masonry Units — Groups, Formats, Properties
2.1 Product families and German unit designations
| Group | Abbrev. | Product standard | Typical German names | Note | |
|---|---|---|---|---|---|
| Clay masonry (Mauerziegel) | Z | EN 771-1 + DIN 105-100 | Vollziegel VZ, Hochlochziegel HLz, Verbundziegel VMz, Voll-HLz VMz/VHLz, Kermauerziegel KMz, Planziegel HLzW/HLzP (grinded, thin-joint), hinterlüftete Vorsatzschalensteine | strength class fb 4-100 on gross area; groups A/B/E/T1/T2-T4/LL by Lochanteil and use | |
| Lime-sandstone (Kalksandstein) | KS | EN 771-2 + DIN V 106 | KS-Vollstein, KS-Hochloch, KS XL (thin-joint large block), KS-Planstone | dense (1.8-2.2), good sound mass; thin-joint DM only | |
| autoclaved aerated concrete (Porenbeton) | PB | EN 771-4 + DIN V 20000-404 | Plansteine PP, Planblöcke, Porenbeton-Sturz elements (PP + U-Schalen) | low density 0.35-0.8 RDK; thin-joint DM 1-3 mm | |
| Light-weight aggregate concrete (Leichtbeton) | LB | EN 771-3 + DIN V 18151-153 | Hohlblocksteine Hbl (1K-6K chamber classes), Vollblocksteine Vbl, Plan-LSB | chambered granulate/brick-porite; also LM mortar variants | |
| Normal-weight concrete (Beton) | NB | EN 771-3 | Hochblock-/Betonstein, block formats | dense, foundations and aggressive exposure | |
| Natural stone (Naturstein) | — | EN 771-6 + NA Annex L | Bruchsteine, Werksteine, Schichten | design per NA.L; movement joints up to 12 m |
Lochanteil (gross-area void ratio) classes that drive unit grouping: Vollstein < 12.5 %; Hochloch ~15-50 % of bed face (vertical perforation, "mit Kammern"); large-format elements <= 1 m length. The void pattern decides fb declaration basis, shear contribution (§7) and slotting limits (§10.8). [VERIFY — class boundaries per current EN 771-1]
2.2 Formats and dimensional coordination (DIN 4172)
- Grid basic module BM = 12.5 cm; work sizes (Arbeitsmaße) of masonry =
stone + joint. Richtmaß example from the digest: nominal wall 25 cm grid → stone 24 cm + 1 cm joint (Nennmaß 24); room width 400 cm → 401 cm dimension line with plaster. Concrete keeps 25 → 25. [VERIFY]
- Theoretical stone sizes from BM 25 - 1 cm joint: length 24 cm, width 11.5 cm
(= 25/2 - 1), height NF = 25/3 x 2 - joint ≈ 11.3 cm (normal format). Thin formats 2DF/DF give storey heights as multiples of the layer (Schicht) height: common stone heights 52 / 71 / 113 / 155 / 175 / 238 mm feed the planning grid (Tafel 10.3: Kopfzahl n -> length 0.615/1.240/1.990 m ... for n = 5/10/16 units at 12.5 cm module, joint 1 cm). [VERIFY exact grid]
- Wall nominal thicknesses in use: 11.5, 15, 17.5, 24, 30, 36.5, 42.5, 49 cm
(single-leaf); two-leaf totals add cavity 4-15 cm + outer leaf 9-11.5 cm.
- Small-format KS (thin-joint system units, from the labour digest):
4DF (248x115x238) for t = 11.5 cm; 5DF for t = 15 cm; 4DF (248x240x113) for t = 24 cm; 5DF for t = 30 cm. Unit counts: 16 St/m² (t 11.5), 16 St/m² (t 15), 31 St/m² (t 24), 32.5 St/m² (t 30); mortar demand 7-9 l/m². [VERIFY pairings]
2.3 Density classes (Rohdichteklassen, RDK) and unit weight
Artificial-stone masonry incl. joints, built dry [from DIN EN 1991-1-1/NA + DIN 1055 digest]:
| RDK of unit | gamma kN/m³ | RDK | gamma kN/m³ | RDK | gamma kN/m³ | |
|---|---|---|---|---|---|---|
| 0.31-0.35 | 5.5 | 0.81-0.90 | 11.0 | 1.41-1.6 | 16.0 | |
| 0.36-0.40 | 6.0 | 0.91-1.00 | 12.0 | 1.61-1.8 | 18.0 | |
| 0.41-0.45 | 6.5 | 1.01-1.20 | 14.0 | 1.81-2.0 | 20.0 | |
| 0.46-0.50 | 7.0 | 1.21-1.40 | 16.0 | 2.01-2.2 | 22.0 | |
| 0.51-0.55 | 7.5 | — | — | 2.21-2.4 | 24.0 | |
| 0.56-0.60 | 8.0 | — | — | 2.41-2.6 | 26.0 | |
| 0.61-0.65 | 8.5 | 0.66-0.70 | 9.0 | 0.71-0.75 | 9.5 | |
| 0.76-0.80 | 10.0 | — | — | — | — |
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/masonry-construction/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/felixkarevo/construction-skills/masonry-construction)