Stairs, ramps and lifts (Treppen, Rampen, Aufzüge) for DACH design — stair set-out from OKFF-to-OKFF height, Steigungsverhältnis 2s+a=60–65 cm (Schrittmaß/Blondel), tread ≥26 cm, rise ≤19(–21) cm as German practice values (VERIFY against DIN 18065 current), lichte Durchgangshöhe ≥2.00 m (design 2.10 m), floor-opening length algorithm, winder and spindle-stair geometry after DIN 18065:2020-08 (Lauflinie, walking zone, usable width, headroom), flight/Podest/door rules (no door onto flight, Podest…
Install
npx vskill@latest install felixkarevo/construction-skills/stairs-vertical-circulationSKILL.md
Stairs and Vertical Circulation (Treppen, Rampen, Aufzüge) — DACH Practice Skill
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
The stair set-out, code-check, lift-sizing and preliminary structural coordination skill for vertical circulation: the one (or two) stairs connecting Keller → EG → OG → DG in a one/two-family house or Mehrfamilienhaus, the Rampe that joins or replaces them, and the Aufzug that takes the traffic when the building gets tall enough to require one. It exists so that a stair drawn in FreeCAD has a real riser count derived from the true floor-to-floor height, a going satisfying both the comfort formula and the governing German dimensional rules, a floor opening long enough for real headroom, a Treppenlaufplatte whose thickness came from a span/depth rule, and a Geländer whose anchorage was decided before the pour.
Stairs are the most dimension-sensitive element in a plan. Get the riser count wrong by one and every landing level, door head and Treppenöffnung is wrong. Get the headroom wrong and the mistake surfaces when someone hits their head on a poured slab. Unlike a wall, a stair cannot be adjusted 50 mm later.
German regulatory terms are kept in parentheses: submissions, drawings and authorities communicate in German.
0. How to use this skill
Use it when the task involves: setting out a stair from a storey height (rise, going, Lauf length, Podeste, opening, headroom); choosing the type for a tight plan; checking the escape function of a Treppenraum; preliminary RC stair design for coordination with the Tragwerksplaner; acoustic separation of stair/lift from protected rooms; ramp gradients; lift car/shaft/pit sizing; modelling any of it in FreeCAD.
Read §1 (reality check) and §2 (evidence tiers) before quoting any number.
| Sibling skill | Overlap | |
|---|---|---|
fire-protection-building | Full Brandschutzkonzept — here only the stair/lift interface | |
building-acoustics | Complete Trittschall/Luftschall method — here the stair/shaft specifics | |
concrete-detailing | General anchorage, laps, cover, joints — here stair applications | |
structural-systems / seismic-design | Frame, storey heights, stair brace + short columns | |
building-services-tga | Lift as equipment, machine-room ventilation, emergency power | |
| accessibility (DIN 18040) library skill | Full barrierefrei route design — here ramps/lift minimums | |
building-planning-spatial / building-regulations-permits | Core location; LBO per Bundesland, Genehmigung |
1. Reality check — licensing and liability
This skill produces design aids for planning and FreeCAD modelling ONLY.
- Every dimension, thickness, bar size and load here is a **preliminary
set-out figure, code minimum, or labelled rule of thumb**. A stair carries people at height; a preliminary number is not a design.
- **Any stair for real construction must be reviewed, analysed and signed by
a qualified structural engineer (Tragwerksplaner)** under the Prüfstatik/Prüfingenieur regime of the relevant Bundesland (or the equivalent licensed engineer in Austria/Switzerland): Laufplatte, Podest, Podestträger, supporting walls/columns, Geländer anchorage.
- The design must pass the local Bauamt (Baugenehmigung). Stair width,
enclosure, Rettungsweg geometry and lift requirements are LBO items — separate from and additional to any structural standard.
- Never present output as construction-ready; the framing is always
"preliminary set-out and sizing for coordination — to be verified and signed by the Tragwerksplaner and approved by the Bauaufsichtsbehörde." Say it unprompted when a user asks for a Biegelehre list for the fixer, wants to shave the plate "because it looks thick", or asks to skip the Podest beam this week.
- Never certify — no stamped drawings, no Standsicherheitsnachweis, no
signature block.
- Guards are life-safety, not finish. A Geländer failing at 900 mm over a
stairwell drops someone onto concrete; the §19 loads are the minimum check and the anchorage is the engineer's, not a catalogue's.
- Standards move; state law differs. German anchors not carried in the
project's verified source digests (most DIN 18065 category values, DIN 18040 gradients, some EN 1991/1992 constants) are tagged VERIFY against the current standard. The MBO is framework law — the LBO of the Bundesland governs.
2. Evidentiary tiers
| Tier | Status | Content | Consequence | |
|---|---|---|---|---|
| T1 | Legal anchor | MBO/LBO duty that buildings be arranged so use is ordnungsgemäß and Rettungswege function → makes the allgemein anerkannten Regeln der Technik (DIN 18065, DIN 18040, Eurocodes via VVB/TB) binding | Public-law minimum; downward deviation needs an Abweichung | |
| T2 | Normative texts | DIN 18065 (Treppen), DIN 18040-1/-2, EN 1991-1-1, EN 1992-1-1/NA, EN 1998-1/NA, DIN 4109 series, DIN 8989, EN 81 series, ASR A2.3 | Quote with edition; values here are excerpts | |
| T3 | Digested excerpts | Escape-stair rules/widths from the digested MBO/LBO fire chapter; lift car/pit/headroom/DIN 8989 data from the digested building-services-tga chapter; DIN 4109-32 stair table; EN 1991 stair loads + EN 1992 anchorage/cover/slenderness/crack tables from the digested structural tables | Usable for iteration; final proof re-derived from the norm | |
| T4 | Practice / carried-over values | Proportion bands, footprint numbers, site defaults kept from prior practice where they align with German norms | Pre-design only; label as estimate |
Any row whose exact normative value is not in the digested sources carries VERIFY against DIN/EN … current — the value may be right, but it was not re-derived from the standard text.
3. The set-out algorithm (run first, every time)
Never draw a stair before running these eight steps in order. Most stair errors are out-of-order: someone drew a stair shape, then fit risers into it.
3.1 Worked run — H = 3200 mm
| Step | Operation | Result | |
|---|---|---|---|
| 1 | Slab 200 + screed/finish 60 + clear height | H = 3200 mm | |
| 2 | n = round(3200/175) = 18.29 → 18 | s = 177.8 mm | |
| 3 | 177.8 ≤ 190 ✓ [VERIFY] | pass | |
| 4 | a = 630 − 355.6 = 274.4 → 275; 2s+a = 630.6 | pass (≥ 260) | |
| 5 | Going = 17 × 275 | 4675 mm | |
| 6 | Available plan length 3600 mm | FAILS → Halbwendung (§8) | |
| 7 | Floor opening | see §5.2 | |
| 8 | Split 9 + 9; rise per Lauf = 1600 mm | pass |
Lesson: a 3200 mm storey at comfortable proportions needs 4.7 m of straight run. Almost no standard urban house has it in one room — the Halbwendung is arithmetic, not aesthetics.
4. Rise/going proportion — Schrittmaß (Steigungsverhältnis)
4.1 The formula
François Blondel (1675) observed that stride shortens when climbing by roughly twice the rise. German stair practice carries this as the Schrittmaß, and DIN 18065 as the Steigungsverhältnis:
s = Steigung (rise), a = Auftritt (going, nosing-to-nosing, without Überstand). A level pace ≈ 630 mm; each rise unit consumes two pace units. Gait locks into cadence within two steps — which is why uniformity matters more than the absolute value: all rises 5 mm tall is fine; one rise 15 mm off is a trip hazard. Schrittmaß is a comfort filter inside the code box, never instead of it. DIN 18065:2020-08 itself sets the step rule at 590 mm to 650 mm (S.4); the 600 mm lower end above is the comfort band of this skill.
4.2 Companion checks
| Rule | Band | Use | |
|---|---|---|---|
| Product (Treppenregel) | s·a ≈ 46,000–48,500 mm² | Catches extremes that pass 2s+a [T4] | |
| Sum | s + a ≈ 450–470 mm | Site mental check [T4] | |
| Neigungswinkel | 30–37° comfortable; ~37–38° domestic max | tan α = s/a [T4/VERIFY per category] |
4.3 Combination table (2s + a ≈ 630 mm)
| s (mm) | a (mm) | 2s+a | s·a (mm²) | Pitch | Feel | Status | |
|---|---|---|---|---|---|---|---|
| 150 | 330 | 630 | 49,500 | 24.4° | Grand/public feel | ✓ — long going | |
| 165 | 300 | 630 | 49,500 | 28.8° | altengerecht default | ✓ | |
| 170 | 290 | 630 | 49,300 | 30.4° | Very comfortable | ✓ | |
| 175 | 280 | 630 | 49,000 | 32.0° | Main-house default | ✓ | |
| 178 | 275 | 631 | 48,950 | 32.9° | The 18-step/3200 result | ✓ | |
| 180 | 270 | 630 | 48,600 | 33.7° | Common practice | ✓ | |
| 185 | 260 | 630 | 48,100 | 35.4° | Steep, secondary | ✓ at the going floor | |
| 190 | 250 | 630 | 47,500 | 37.2° | Going below 260 practice floor | ✗ without VERIFY-waiver | |
| 200 | 230 | 630 | 46,000 | 41.0° | A ladder, not a stair | ✗ ✗ |
4.4 Uniformity and the code box
| Item | Limit | Basis | |
|---|---|---|---|
| Rise/going uniformity in a Lauf | equal within ~5 mm design intent; never "adjust the last step" on site | [T4 — tolerancing per DIN 18202 family; VERIFY stair-specific clause] | |
| Steigung cap | ≤ 190 main / ≤ 210 secondary | [T4 German practice, VERIFY DIN 18065 category table] | |
| Auftritt floor | ≥ 260 dwelling main (the old generic 250/254 is below current German practice — don't use without VERIFY) | [VERIFY] | |
| Nosing (Überstand) | 20–30 mm where a is tight, radiused/bevelled ≤ 15 mm, uniform | [T4/VERIFY] | |
| Open riser / baluster openings | must not pass a 120 mm sphere (German child-safety practice; old skill carried 100 mm — design default stays ≤ 100 mm) | [VERIFY against DIN 18065 current] |
4.5 When the ideal going doesn't fit
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/stairs-vertical-circulation/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/felixkarevo/construction-skills/stairs-vertical-circulation)