Skill v1.0.0
currentAutomated scan100/100name: timber-steel-design description: > Structural design of timber (Nadel- und Laubholz) and steel building systems to Eurocode 5 and Eurocode 3 for DACH practice: timber products and strength classes C14-C40 / D30-D70 / GL24h-GL36h plus CLT, LVL, duo/trio beams with fm,k / ft,0,k / fc,0,k / fv,k / E0,05 tables, kmod by load duration + service (use) class, kdef, gamma_M = 1.3 members / 1.1 simplified fastener check / reduced gamma_M,fi in fire; member design (bending incl. lateral-torsional buckling k_crit chain, axial buckling kc chain, shear cracked-section b_ef, bearing perpendicular to grain kc,90, biaxial bending km = 0.7/1.0, deflection + vibration serviceability, notched ends kv and transverse tension reinforcement); joints (nails with penetration t >= 9d, screws with f_ax,k and glued-in rods fg,k = 4.0 N/mm2, dowels/bolts via the yield model with spacing rules a1 = (3+2|cos a|)d etc., ring and shear connectors, DIN 436/440 plates, effective number n_ef); DIN 68800 use classes GK0-GK5 and constructional wood protection; steel: profile families (IPE, HEA/HEB/HEM, channels, hollow sections) with an A/I/W excerpt table, cross-section classes 1-4 + EN 1993-1-5 effective widths, tension, Mpl,Rd bending with MV/MN interaction, shear Av, web bearing, bolted connections (grades 4.6-10.9, preloaded HRSG, Fv,Rd/Fb,Rd, spacing limits, T-stub, block shear), welded connections via fw with beta_w, buckling curves a-d with the chi chain, lateral-torsional buckling Mcr -> chi_LT,mod, imperfection and bracing loads; combined checks in sigma/fd <= 1 format; corrosion protection classes + galvanizing; fire (timber charring rate beta_n + notional layer 7 mm; steel critical temperature and protection menu); framing systems in practice (stud and panel, solid timber/CLT multi-storey, glulam portals and trusses, steel portals, trusses and composite beams) with span/depth rules, plus FreeCAD/IFC modelling defaults. Use when selecting, sizing, checking or modelling timber or steel load-bearing structures for buildings. metadata: version: "1.0.0"
Timber & Steel Design for Buildings (EN 1995 / EN 1993, DACH practice)
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
This skill covers the design logic, code values and detailing rules for the two linear-material systems of European building construction: timber construction (Holzbau) to Eurocode 5 (DIN EN 1995-1-1 + National Annex) and steel construction (Stahlbau) to Eurocode 3 (DIN EN 1993-1-1 + National Annex), including the fire parts (EN 1995-1-2 / EN 1993-1-2) and the connection rules (EN 1993-1-8 / -1-5, EN 1995-1-1 §8 with fastener ETAs/abZ). It is the design-level companion to the framing-systems skill (which answers which system) and to building-materials (which answers what the product is).
In scope: material/design values, member verification chains, fastener and welded connection checks, stability (buckling / lateral-torsional buckling), serviceability (deflection, vibration), durability and use classes, structural fire design, practical framing systems with span/depth rules, worked calculation chains, FreeCAD/IFC modelling defaults.
Out of scope: whole-building action tables and combinations (→ a loads/structural-systems skill), seismic design (→ seismic-design), foundation design under column feet and hold-downs (→ geotechnics-foundations), execution and contract logic (→ construction-detailing), concrete and masonry design (→ concrete-detailing, masonry-construction).
Sibling skills
| Skill | Where this file hands off | |
|---|---|---|
| structural-systems | system choice at building level (massive vs timber vs steel) | |
| building-materials | product standards, densities, λ/μ data, CE/DoP status of sections & boards | |
| fire-protection-building | building classes GK1-GK5, required F/R durations, escape routes | |
| construction-detailing | joint geometry, water-shedding, layer sequences, tolerance strategy | |
| concrete-detailing | steel/timber-to-concrete interfaces: anchors, base plates, WCC topping | |
| seismic-design | horizontal actions, ductility, bracing system choice | |
| geotechnics-foundations | uplift and thrust into ground; column feet |
Reality check — read before using any number
- **This skill produces design aids and calculation guidance for planning,
pre-dimensioning and FreeCAD modelling ONLY.** Every span, section, bolt count, screw spacing and charring rate below is a preliminary sizing aid, a code minimum, a table excerpt, or a rule of thumb.
- **Any design intended for construction of a real occupied building must be
analysed, designed and signed by a qualified structural engineer (in Germany: Tragwerksplaner per Landesbauordnung, plus Prüfstatik where required; in Austria/Switzerland the locally licensed equivalent). This is *more* true for timber and steel than for massive construction: these systems are connection-governed, stability-governed and uplift-governed**. A missed hold-down, an unbraced compression flange or an under-designed bolt group is a collapse mechanism, not a crack.
- National Annex (NA) differences are the rule, not the exception. gamma_M
values, kmod wind rules, lateral-torsional buckling parameters, buckling curve assignments and deflection recommendations differ DE/AT/CH and move with every code edition. The digests behind this file reflect EC5 2010-12 + German NA 2013-08 (+ A2 2014) and EC3 + German NA, early-2020s handbook state — VERIFY the currently introduced edition per project.
- Values reconstructed from source digests carry a
VERIFYflag. Treat
the flags as binding. Several table columns were transposed or garbled during extraction (flagged where detected). Never quote a flagged number to a fabricator.
- **Never present model output, a span-table lookup or a calculation from this
file as construction-ready.** The correct framing is always "preliminary sizing and coordination geometry — requires design and signature by a qualified structural engineer". Say it unprompted when a user starts ordering steel, sending cutting lists to a timber workshop, or deleting a brace "because the model still stands".
- Never certify. No stamped drawing, no stability certificate, no
fabrication drawing presented as approved-for-construction.
- Loads are never assumed. Basic wind speed, snow zone, site elevation, use
category and (where relevant) seismic zone come from the current maps and the project brief. Lightweight structures are frequently uplift-governed rather than gravity-governed — the reverse of massive construction.
Evidence tiers
| Tier | Meaning | Examples here | Use | |
|---|---|---|---|---|
| T1 | EN + NA design value formulas and tables | fm,k, kmod, gamma_M, chi-curves, Fv,Rd | citable after edition check | |
| T2 | Product-standard geometry (EN 10365, EN 336, EN 14080, EN 16351) | profile nominal sizes, tolerances | spec-grade after lookup | |
| T3 | Handbook tables and worked-example digests | section property excerpts, Rk of nails, bolt capacities | guidance; flagged cells | |
| T4 | Rules of thumb | span/depth ratios, 1-2 % bracing force | massing only |
Section 1: Code basis — what governs what
1.1 Standards map
| Topic | Timber | Steel | |
|---|---|---|---|
| Basis / actions | DIN EN 1990, EN 1991-1-1…-1-6 + NAs | same | |
| Design (ULS/SLS) | DIN EN 1995-1-1 + NA | DIN EN 1993-1-1 + NA | |
| Fire | DIN EN 1995-1-2 + NA | DIN EN 1993-1-2 + NA | |
| Connections | EN 1995-1-1 §8 + fastener ETAs / abZ | EN 1993-1-8 (bolts, welds), EN 1993-1-5 §6 (web bearing/stiff panels) | |
| Plates / class 4 | EN 1995-1-1 §6.2 (cracked-section shear) | EN 1993-1-5 (effective widths, patch loading, shear buckling) | |
| Buckling / LTB | EN 1995-1-1 §6.3 | EN 1993-1-1 §6.3 | |
| Composite floors | wood–concrete (WCC) via ETA pin connectors | EN 1994-1-1 / -1-2 (head studs, trapezoidal sheet) | |
| Material products | EN 338 (strength classes), EN 336 (sizes & deviations), EN 408 (test/strength), DIN 4074-1 (visual/machine grading S7/S10/S13), EN 1194 + EN 14080 (BSH/glulam), EN 16351 (CLT/Brettsperrholz), EN 14374 (LVL), EN 15497 (finger-jointed solid), (duo/trio beams: Balkenschichtholz via EN 14080), EN 636 (plywood), EN 300 (OSB) | EN 10025 (hot-rolled grades S235…S700), EN 10210/-10219 (hollow sections), EN 10365 (nominal sizes & designation), EN 10218 (welded sections) | |
| Fasteners | EN 14592 (dowels, nails, screws, bolts — strength & stiffness), EN 10230-1 (nail dimensions), EN 14566 (ring & shear plate connectors), EN 14545 (screw-in inserts), ETAs for structural screws and glued-in rods | EN 15048 (fit bolts), EN 14399 (preloaded HRSG 8.8/10.9), ISO 4063 + ISO 2553 (weld process/symbols), EN 1090-2 (execution) | |
| Durability | DIN 68800-1 (Gebrauchsklassen GK0-GK5), -2 (chemical + constructional protection), DIN 4074-1, EN 350 (natural durability) | EN ISO 12944 (corrosivity categories C1-C5 + immersion), EN ISO 1461 (hot-dip galvanizing), EN 10346 (continuously coated strip) | |
| Execution | DIN 18334 (ATV timber works), trade rules of the roof/carpentry trades | EN 1090-1/-2 (EXC 0-4), DIN 18335 (ATV steel works) | |
| Fire classification | DIN 4102 / DIN EN 13501-2 (F30-F180 ↔ R/E/I) | same |
⚠ VERIFY editions and NA currency per Bundesland/country before citing.Fastener approvals are time-limited: a handbook may list a punched-plate/angleconnector approval (abZ) whose validity expired years earlier — never carry anapproval number from a table into a project without checking its current status.
1.2 Partial factors and combinations (starting point, German NA of the digest edition)
Actions (persistent/transient, STR): γ_G unfavourable 1.35 / favourable 1.00; γ_Q 1.50. ψ0/ψ1/ψ2 for buildings: living/office A,B 0.7/0.5/0.3; assembly C 0.7/0.7/0.6; retail D 0.7/0.7/0.6; storage E 1.0/0.9/0.8; roof (non-accessible) H 0/0/0; snow ≤ 1000 m NN 0.5/0.2/0.0; wind 0.6/0.2/0.0.
Timber resistances: γ_M = 1.3 members (solid, BSH, and most wood-based panels incl. CLT/Balkenschichtholz); γ_M = 1.1 dowel-type connections by the simplified verification; 1.3 exact yield-theory check; 1.3 ring/ shear-plate connectors (§5.7 — different failure mode from dowel bending, do not reuse 1.1); steel connector parts in tension/shear 1.3; nail-plate (Nagelplatte) plate check 1.25.
Fire design — CORRECTED, the earlier "γ_M,fi table" was a mislabelling, not a real contradiction with the worked example (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.155/159-160/174-176, Tab. 4.12, EN 1995-1-2 Tab. 2.1 + DIN EN 1995-1-2/NA NDP to 2.3(2) Note 1): the differentiated table (solid 1.25, glulam 1.15, panels 1.15, LVL 1.1 — resolves the "1.0 (1.1 in the digest)" ambiguity in favour of 1.1, shear connections timber-side 1.15 / outer-steel-plate 1.05, pull-out 1.05) is actually k_fi, the coefficient converting the 5 %-characteristic value to the 20 %-quantile fire strength: f_20 = k_fi·f_k. γ_M,fi itself is 1.0, uniformly, for ALL timber materials and connections — so the correct fire design equation is f_d,fi = k_mod,fi·(k_fi·f_k)/1.0, with k_fi in the numerator, not a γ_M in the denominator. The worked fire example (which applies 1.0 to member bending) was already right; only the general statement needed relabelling and moving k_fi to the correct place in the equation.
Steel resistances: γ_M0 = 1.0 (cross-section), γ_M1 = 1.1 (stability: buckling, LTB, patch loading per 1993-1-5), γ_M2 = 1.25 (net sections, bolt bearing, welds) — as used in the worked example chains of this file.
⚠ VERIFY NA state (γ_M1 was 1.0 for section checks in the example chain fortension M-N interaction; treat 1.0/1.1 split as edition-dependent).
Timber combination rule (the classic trap): design value X_d = X_k · k_mod / γ_M sits in the denominator, so the governing load case is the one with maximum F_d / k_mod, not maximum F_d. Example (solid/BSH, CL1): 1.35G + 1.5S → F_d = 12.4 kN/m over k_mod 0.6 → 20.7; 1.35G + 1.5W → k_mod 1.0. Always run the division for every combination (permanent 0.6, snow short 0.9, wind NA 1.0, medium 0.8, very short 1.1).
Fire combination (both materials): γ_G = γ_Q = 1.0, variables at ψ1 (worked timber R30: 0.5); exceptional design situation.
Section 2: Framing-system taxonomy (generic)
2.1 Timber systems
| ID | System | Load path | Lateral system | Design consequence | |
|---|---|---|---|---|---|
| T1 | Stud-and-panel frame (Holzrahmenbau) — platform (storey-high walls on deck) or balloon (2-storey studs + let-in band) | sheathing → studs → top/sill plate → deck/plate → foundation | shear-stiff board sheathing (nail/screw line spacing = capacity) or crossed braces; hold-downs at panel ends | every chord force is a fastener-group design; studs must sit under joists (in-line framing); platform settlement = cumulative perpendicular compression (limit storeys or use T2) | |
| T2 | Solid timber (Massivholz) — board stack (BSP), CLT (Brettsperrholz), X-lam LVL | gravity end-grain → end-grain (no transverse compression), so stacking is settlement-free | glued/dowel-laminated panels act as diaphragms and disc plates | CLT outer plies define span direction; ~50 % of section effective along grain in walls; large sawn openings possible; few joints = easy airtightness | |
| T3 | Post-and-beam / frame (Ständerwerk, Skelett) — glulam/LVL columns + beams | beam → column via steel insert, slotted plate, saddle timber, or pincer detail | braced bays, cores, or moment frames | node = perpendicular-tension (splitting) problem; twin beams either side of column halve eccentricity; interposed horizontal timber in compression path = long-term settlement | |
| T4 | Roof systems — purlin roof (Pfettendach), rafter roof (Sparrendach), truss/binder roof | purlins on trusses/posts; rafter+tie triangle; binder with diagonals | triangulated truss planes, sheathing, ridge/purlin bracing | purlin roof = bending structure, lightest depth; rafter roof needs a real tie (tie beam suspended against sag, collar in upper third); binder = slender chords, large depth | |
| T5 | Traditional/hybrid — log (Blockbau), half-timber (Fachwerk), timber-laced masonry, timber beams in masonry houses | stacked members / storey-high trusses with braced panels | integral diagonals (Kopf-/Fußband), sheathing | settlement and shrinkage must be absorbed in details; beam ends into masonry: ventilated, GK class rises; Fachwerk grid ≈ 1.25 m Alemannic canon; solid floor beams ≤ ~5 m | |
| T6 | Wood–concrete composite (WCC) floor | concrete compression chord + timber tension chord via shear connectors | slab diaphragm | connector pattern governs; moment reversal in continuous/cantilever systems swaps chords; concrete gives mass (acoustics) + fire + protection |
2.2 Steel systems
| ID | System | Load path | Notes | |
|---|---|---|---|---|
| S1 | Portal frame (2- or 3-hinged, haunched) | rafter–column moment frame → base plate → footing | in-plane stiff → open end façades; longitudinal bracing still needed; 3-hinged apex pin lets halves be transported if frame height ≤ ~4 m | |
| S2 | Trusses (Fachwerkträger) — parallel-chord, pitched, bow | chords carry the moment as a couple; diagonals shear | load at nodes only; tension diagonals preferred; short compression diagonals; avoid twin slender compression bars, acute angles; non-triangulated quads = Vierendeel = heavier | |
| S3 | Braced/multi-storey frame + composite floors | beams → columns → core/braces → foundation | head studs make the slab a compression flange; slim-floor keeps services below a flat soffit; pinned default (fin plate), moment where drift demands | |
| S4 | Grid shells / space frames / cable systems | membrane-like in-surface forces | triangulation = pure axial; quad grids need diagonal bracing; cables use steel's tension fully (no buckling); node cost, not member cost, rules | |
| S5 | Cold-formed light-gauge framing | stud-and-panel analogue in steel | design to EN 1993-1-3/-1-5 (class 4 always, stiffened plates) — system logic in the framing-systems skill |
2.3 Span/depth working limits (T4 — massing only)
| Element | Preliminary depth | Practical band | |
|---|---|---|---|
| Steel rolled beam | h ≈ L/10 … L/18 | rolled to ~20 m; beyond → welded girder h ≈ L/8 … L/12 | |
| Steel portal rafter | depth ≈ L/40 … L/55 (haunch: 1.5-2× rafter depth, length L/10 … L/7) | clear spans 12-35 m economical | |
| Composite beam | h ≈ L/18 … L/22 | office grids 6-12 m | |
| Truss (steel) | depth ≈ L/10 … L/16 | 10 m → >100 m | |
| Timber binder (truss) | depth ≈ L/6 … L/12 | 8-25 m | |
| Glulam beam | h ≈ L/15 … L/20 | ~20 m practical with restraint | |
| Timber joist | h ≈ L/18 … L/24 | 3-6 m; box/trough elements to 14 m; rafters and purlins of a house: spacings and preferred sections in S.1 to S.3 | |
| CLT one-way floor | t ≈ L/30 … L/35 | 3-6 m (5-ply typical) |
⚠ VERIFY at analysis: at the ends of every band, buckling, LTB, deflection,vibration, fire or the connection governs — not bending strength.
2.4 Non-negotiable conceptual rules (both materials)
- A frame is stiff in its plane only. Portal/skeleton systems need an
explicit bracing system in both directions; without it the building is a mechanism longitudinally. Show the bracing on the model.
- Buckling length = spacing of the restraints you designed, not the member
length. Unrestrained compression flange (rafter soffit at eaves, column inner flange, truss top chord) → fly braces, knee braces, sheetingdiaphragm attachments. Missing fly-bracing is the classic portal failure.
- Uplift must reach the ground in a designed chain: cladding fasteners →
purlin → cleat → rafter/truss → clip → plate → stud → anchor/hold-down → foundation. Every link designed; no "bedding friction".
- The connection IS the structure. Timber: dowel group + perpendicular
tension path. Steel: bolt group, weld, plate bending, block shear, web crippling, column-flange deformation — checked separately.
- Bearing needs area and a path around weakness: timber perpendicular
compression (k_c,90 + (3+l+3)·b spreading), steel unstiffened web (crippling check), base plate on grout with a shear key (Schubknagge) so anchors take uplift, not shear.
- **Horizontal thrust of a pitched frame goes into a tie or a moment base —
never "the slab".** Hand check H ≈ w·L²/(8f) (three-hinged, conservative).
- Shop-weld, site-bolt. Field welding means no procedure control, no NDT,
damaged coating; redesign the detail instead.
Section 3: Timber material and characteristic values
3.1 Solid softwood classes (Nadel-Vollholz, DIN EN 338 / EN 1995-1-1 Table 3.1)
Characteristic values N/mm² at reference moisture 12 % (sizes per EN 336). Grading per DIN 4074-1: S7 → C16/C18 (fir/larch/Douglasie C16; Fichte/Kiefer C18), S10 → C24, S13 → C30/C35 (Douglasie C35); dry-graded (TS) ≤ 20 % MC.
| Class | f_m,k | f_t,0,k | f_t,90,k | f_c,0,k | f_c,90,k | f_v,k | f_r,k | E_0,05 | E_0,mean | E_90,mean | G_mean/G_0,05 | ρ_k | ρ_mean | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| C18 | 18 | 10 | 0.4 | 18 | 2.2 | 3.4 | 0.8 | 6000 | 9000 | 300 | 560 / 375 | 320 | 380 | |
| C24 | 24 | 14.5 | 0.4 | 21 | 2.5 | 4.0 | 0.8 | 7400 | 11000 | 370 | 690 / 460 | 350 | 420 | |
| C30 | 30 | 19 | 0.4 | 24 | 2.7 | 4.0 | 0.8 | 8000 | 12000 | 400 | 750 / 500 | 380 | 460 | |
| C35 | 35 | 22.5 | 0.4 | 25 | 2.7 | 4.0 | 0.8 | 8700 | 13000 | 430 | 810 / 540 | 390 | 470 | |
| C40 | 40 | 26 | 0.4 | 27 | 2.8 | 4.0 | 0.8 | 9400 | 14000 | 470 | 880 / 590 | 400 | 480 |
CONFIRMED against Wendehorst Bautechnische Zahlentafeln (37th ed.) Tab. 12.1, itself citing DIN EN 1995-1-1:2016-07 Tab. 3.2 / DIN EN 338:2010-02 Tab. 1 — the table above is correct as printed (E_0,05 < E_0,mean, not transposed; G_05 = 2/3·G_mean per NA). Two cells corrected against that source: C24 f_v,k is 4.0 (not 3.5 — only C18 sits at 3.4, all of C24-C40 are flat at 4.0), and C35 f_c,90,k is 2.7 (not 2.8). E_90,mean column added from the same table (was previously only a single ⊥-grain estimate in §3.5).
3.2 Solid hardwood (Laubholz, DIN EN 338)
| Class | f_m,k | f_t,0,k | f_t,90,k | f_c,0,k | f_c,90,k | f_v,k | E_0,mean | E_0,05 | E_90,mean | G_mean/G_0,05 | ρ_k | ρ_mean | typical species | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D30 | 30 | 18 | 0.6 | 24 | 5.3 | 3.9 | 11000 | 9200 | 730 | 690 / 460 | 530 | 640 | Eiche (oak), LS10 | |
| D35 | 35 | 21 | 0.6 | 25 | 5.4 | 4.1 | 12000 | 10100 | 800 | 750 / 500 | 540 | 650 | Buche (beech), LS10 | |
| D40 | 40 | 24 | 0.6 | 27 | 5.5 | 4.2 | 13000 | 10900 | 870 | 810 / 540 | 550 | 660 | Buche, LS13 | |
| D60 | 60 | 36 | 0.6 | 33 | 10.5 | 4.8 | 17000 | 14300 | 1130 | 1060 / 710 | 700 | 840 | Buche (high grade) |
f_r,k ≈ 1.2. CONFIRMED against Wendehorst Tab. 12.2 (DIN EN 338:2016-07 Tab. 3) — D60 f_t,90,k and f_v,k are exactly 0.6 / 4.8 as printed, not uncertain; E/G/ρ columns not transposed. G_mean/G_0,05 and E_90,mean columns added from the same source (previously missing for hardwood).
3.3 Glulam / BSH (DIN EN 1194/14080, combined "c" and homogeneous "h" strength)
| Class | f_m,k | f_t,0,k | f_t,90,k | f_c,0,k | f_c,90,k | f_v,k | f_r,k | E_0,mean | E_0,05 | E_90,mean/05 | G_mean/G_05 | G_r,mean/G_r,05 | ρ_k | ρ_mean | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GL24c (combined) | 24 | 17.0 | 0.5 | 21.5 | 2.5 | 3.5 | 1.2 | 11000 | 9100 | 300/250 | 650/540 | 65/54 | 365 | 400 | |
| GL28c | 28 | 19.5 | 0.5 | 24.0 | 2.5 | 3.5 | 1.2 | 12500 | 10400 | 300/250 | 650/540 | 65/54 | 390 | 420 | |
| GL30c | 30 | 19.5 | 0.5 | 24.5 | 2.5 | 3.5 | 1.2 | 13000 | 10800 | 300/250 | 650/540 | 65/54 | 400 | 430 | |
| GL32c | 32 | 19.5 | 0.5 | 24.5 | 2.5 | 3.5 | 1.2 | 13500 | 11200 | 300/250 | 650/540 | 65/54 | 400 | 440 | |
| GL24h (homogeneous) | 24 | 19.2 | 0.5 | 24 | 2.5 | 3.5 | 1.2 | 11500 | 9600 | 300/250 | 650/540 | 65/54 | 385 | 420 | |
| GL28h | 28 | 22.3 | 0.5 | 28 | 2.5 | 3.5 | 1.2 | 12600 | 10500 | 300/250 | 650/540 | 65/54 | 425 | 460 | |
| GL30h | 30 | 24.0 | 0.5 | 30 | 2.5 | 3.5 | 1.2 | 13600 | 11300 | 300/250 | 650/540 | 65/54 | 430 | 480 | |
| GL32h | 32 | 25.6 | 0.5 | 32 | 2.5 | 3.5 | 1.2 | 14200 | 11800 | 300/250 | 650/540 | 65/54 | 440 | 490 |
Corrected against Wendehorst Tab. 12.3/12.4 (DIN EN 14080:2013-09), two fixes: 1) "c" tension values f_t,0,k are 17.0/19.5/19.5/19.5, not the 0.6·f_m,k approximation previously shown — GL28c/30c/32c share the same 19.5 ceiling (the formula understated all three). 2) The "h" table previously had a row/class mislabelling: what was printed as "GL32h" actually carried GL30h's values, and what was printed as "GL36h" (not a class in this DIN EN 14080 table at all) actually carried the real GL32h values — both now fixed; GL36h is not in this source table and should be re-sourced (Studiengem. Holzleimbau extended range) before use, not assumed as a linear extrapolation. The "h" tension values (higher, edge lamellae of tension grade) vs "c" (lower) is the real design difference — homogeneous lay-up buys the higher tension strength and is the bending-member default; combined for columns/frames. E_90 and G/G_r are constant across every GL grade (both c and h) — E_90,mean/05 = 300/250 N/mm², G_mean/G_05 = 650/540 N/mm², rolling-shear modulus G_r,mean/G_r,05 = 65/54 N/mm² (≈1/10 of in-plane G — this is the property that governs CLT out-of-plane shear stiffness/failure in a plate FEM model, not the normal shear modulus; missing it silently over-stiffens a CLT plate/shell element in the through-thickness direction). Rolling-shear strength f_r,k = 1.2 for all grades shown (softwood solid timber §3.1: f_r,k = 0.8 — lower than glulam).
BSH trade rules: ≥ 3 (typ. 5+) lamellae of 14-45 mm, tension-zone lamellae of higher grade; finger joints (Keilzinken) factory only; flat-use (querused) bending with NA uplift ≥ 4 lamellae — VERIFY; wide sections (lamella width ≤ ~28 cm practice) need tilt restraint at supports (forked foot, steel shoe).
3.4 Design value and modification factors
X_d = X_k · k_mod / γ_M (ULS)k_h (size) — two DIFFERENT formulas, do not conflate them (Neuhaus,Ingenieurholzbau, 4th ed. 2017, p.313/316-317, EN 1995-1-1 §3.2/§3.3):solid timber (softwood AND hardwood alike), ρ_k ≤ 700: k_h = min[(150/h)^0.2 ; 1.3],h/b in mm, applied to bending (h < 150 mm) and tension (max(h,b) < 150 mm)glulam (both combined "c" and homogeneous "h" grades): k_h = min[(600/h)^0.1 ; 1.1],applied to bending (h < 600 mm, flat/Flachkant loading only) and tension (b < 600 mm)(worked example "C24 14/14 → k_h = 1.014" uses the SOLID-timber formula:(150/140)^0.2 = 1.014 — resolves the earlier ambiguity, not a separate"hardwood variant")k_ℓ: homogeneous glulam ONLY (GL·h, not "c" grades), Hochkant/edge-loadedbending, ≥ 4 lamellae side-by-side → +20 % on f_m,k (k_ℓ = 1.2)
k_mod — load duration × service/use class (NKL / Nutzungsklasse, EN 1995-1-1 Table 3.1; CL1/CL2/CL3 = equilibrium moisture ≤ 12 % / ≤ 20 % / > 20 %):
| Duration (example actions) | CL1 | CL2 | CL3 | |
|---|---|---|---|---|
| permanent (self weight) | 0.60 | 0.60 | 0.50 | |
| long (6 mo-10 a) | 0.70 | 0.70 | 0.55 | |
| medium (1 wk-6 mo; storage E) | 0.80 | 0.80 | 0.65 | |
| short (< 1 wk; snow, live A/B) | 0.90 | 0.90 | 0.70 | |
| very short (< 1 min; wind, impact) | 1.10 | 1.10 | 0.90 |
CONFIRMED against Wendehorst Tab. 12.5 (DIN EN 1995-1-1:2010-12 Tab. 3.1 + NA Tab. NA.4) for solid timber, glulam, LVL/3 and CLT-equivalent panels — CL1 and CL2 columns are identical for these products (only CL3 drops); the previous CL2 column here understated capacity at every duration tier. Panel products take their own lower columns: LVL/1 and Sperrholz EN 636-1 (dry use only) 0.60/0.70/0.80/0.90/1.10 (CL1 only, CL2/3 = "–" not permitted); OSB/2 (dry) 0.30/0.45/0.65/0.85/1.10 (CL1 only); OSB/3-4 and Sperrholz EN 636-2/3, LVL/2 (dry+humid) same run as solid timber's CL1/CL2 columns, CL3 not permitted. German NA wind: k_mod = mean(short, very short) = 1.00 (CL1/2 solid/BSH), 0.80 (CL3).
k_def — creep (final deformation, EN 1995-1-1 Table 3.2 + NA Table NA.5), CORRECTED and complete (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.334-335, Tab. 7.17):
| Product | CL1 | CL2 | CL3 | |
|---|---|---|---|---|
| Solid timber, glulam (BSH), LVL | 0.60 | 0.80 | 2.00 | |
| Balkenschichtholz (duo/trio), CLT (Brettsperrholz), Massivholzplatten, finger-jointed solid | 0.60 | 0.80 | not permitted | |
| Plywood, "Trocken"/dry (NKL1 only) | 0.80 | — | — | |
| Plywood, "Feucht"/humid | 0.80 | 1.00 | — | |
| Plywood, "Außen"/exterior (all 3 NKL) | 0.80 | 1.00 | 2.50 | |
| OSB/2 (NKL1 only) | 2.25 | — | — | |
| OSB/3-4 | 1.50 | 2.25 | not permitted | |
| Particleboard P4 (NKL1 only) | 2.25 | — | — | |
| Particleboard P5 | 2.25 | 3.00 | not permitted | |
| Particleboard P6 (NKL1 only) | 1.50 | — | — | |
| Particleboard P7 | 1.50 | 2.25 | not permitted | |
| Cement-bonded particleboard | 2.25 | 3.00 | not permitted | |
| Fibreboard, medium-hard MBH.LA2 (NKL1 only) | 3.00 | — | — | |
| Fibreboard, hard HB.HLA2 | 2.25 | 3.00 | not permitted | |
| Gypsum board GKB/GKF (NKL1 only) | 3.00 | — | — | |
| Gypsum board GKBI/GKFI, gypsum-fibreboard | 3.00 | 4.00 | not permitted |
Correction to the earlier digest: Balkenschichtholz/CLT/Massivholzplatten/ finger-jointed solid are a separate row from solid timber/glulam — they share the same CL1/CL2 values but are not permitted in NKL3 at all (the earlier digest lumped them into the same row as solid/glulam with kdef = 2.0 in CL3). Plywood's "Außen" (exterior) kdef,CL3 is 2.50, not 2.0.
3.5 Physical behaviour relevant to detailing
- Shrink/swell across grain ≈ 10× along grain: Δu of 1 % → Δd/d = **0.25 %
(softwood) / 0.35 % (hardwood)**, both directions. Worked: C24 18/20 drying 20→10 % MC → Δh = 5 mm. Above fibre saturation (~30 %) no further shrinkage. Consequences: slotted/oversize holes, no cumulative cross-grain shrinkage in a gravity path, never fast green timber tight, cladding gaps sized for the MC swing.
- Moisture at installation: framing ≤ 20 % (KD typical 12-15 %); interior
joinery ≈ 6-8 %; heated-room equilibrium can drop to ~7 % — fast drying = more warp (Verwerfen, Schüsseln, end-checks).
- Density → self weight (kN/m³): C14 3.5 · C16 3.7 · C18 3.8 · C22 4.1 ·
C24 4.2 · C27 4.5 · C30 4.6 · C35 4.8 · C40 5.0; D30 6.4 · D35 6.7 · D40 7.0 · D50 7.8 · D60 8.4 · D70 10.8; BSH GL24h-GL36h 3.7-4.4; plywood (soft/birch) 5.0/7.0; laminate/Tischlerplatte 4.5; particleboard 7.0-8.0; MDF 8.0; cement-bonded 12.0; lightweight fibreboard 4.0.
- E-modulus orientation: E ∥ ≈ 11000 (softwood) / 12000 (oak/beech) MPa
mean-ish, E ⊥ ≈ 370 / 800 MPa — a factor ~30. Thermal: α ∥ 2.5-5·10⁻⁶/K, ⊥ 25-60·10⁻⁶/K (steel 12·10⁻⁶, concrete 10·10⁻⁶).
3.6 Sizes and tolerances (EN 336 / EN 14080)
- Nominal solid-timber sizes are quoted at 12 % reference moisture (15 %
for hardwood); planing stock adds the MTK1/MTK2 machining allowance (table cells lost in digest — VERIFY EN 336). BSH deviations (EN 14080, digest readable subset): width ± 2 mm; bow 4 mm per 2000 mm; set/twist and length bands garbled — VERIFY; curved elements: set per m by lamella count.
- Visual grading limits (DIN 4074-1) are t-/d-relative percentages of knots,
slope of grain, warp, shakes — not machine-readable in the digest; read the standard. Reject on site: large knots in the tension face at mid-span, wane at bearings, shakes, insect attack, staining.
3.7 Engineered products used in buildings
| Product | Standard | Behaviour / use rule | |
|---|---|---|---|
| BSH / glulam | EN 1194/14080 | beams, frames, columns; no code limit on section size — width in practice to b ≈ 24 cm routine (≤ 2 boards side-by-side per lamella), b ≈ 30 cm as practical max; depth h ≈ 200 cm routine, h_max ≈ 250 cm (limited by planer working width, not strength — beyond ~2.5 m a trussed member usually beats a solid web economically); length effectively unlimited via finger-jointing, practically capped by transport (~35-40 m standard, ~50-60 m special transport, field-spliced >100 m executed on site), not the earlier "~1.2 m / 18-20 m" ceiling (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.109-110); design values §3.3 | |
| CLT / Brettsperrholz | EN 16351 | odd layers ≥ 3, outer same grain → defined span dir.; walls ~50 % section along grain; floor t ≈ 140-260 mm for 3-6 m; excellent diaphragm; element fabrication with TBE/CAD-CAM cut-outs | |
| LVL | EN 14374 | strongly anisotropic one-way; rib/edge members; k_mod/kdef slightly below solid (LVL-1/2/3 categories) | |
| Balkenschichtholz (duo/trio, parallel laminations) | EN 14080 | beams/sills; total cross-section ≤ 280 mm; 2-5 parallel-grain laminations of the same strength class, each lamination > 45 mm to ≤ 85 mm thick (Neuhaus p.308, Tab. 7.1); settlement like solid; NKL3 not permitted at all (§3.4 kdef table) — do not specify duo/trio beams in permanently-wet exposure | |
| Finger-jointed solid (Keilgezinkt) | EN 15497 | continuous sections, columns; joints ≤ 15 % of section length? (VERIFY) | |
| I-joists / wood-based composite beams (mechanically-jointed built-up sections) | ETA / EN 1995-1-1 Annex B | web = board/steel, flange = LVL — bearing stiffeners at supports mandatory (web crippling); effective stiffness by the γ-("gamma") method: (EI)_ef = Σ(E_i·I_i + γ_i·E_i·A_i·a_i²), with γ_i = 1/(1+π²·E_i·A_i·s_i/(K_i·l²)) for the mechanically-jointed outer (flange) members and γ=1 for a rigidly-glued middle member; per-fastener design force F_i,d = (V_max,d/(EI)_ef)·(γ_i·E_i·A_i·a_i·s_i); web-buckling limit h_w + 0.5·(h_f,c+h_f,t) ≤ 70·b_w (Neuhaus, Ingenieurholzbau, p.786-789, Tab. 22.5/22.6) — engineered I-joists/box beams are normally bought to a manufacturer ETA rather than hand-designed, but this is the underlying method if a bespoke nailed/screwed built-up section is being modelled | |
| Wood-fibre / particle / OSB / plywood boards as structure | EN 13169?/EN 300/EN 636 | shear diaphragms and diaphragm floors; nailing edge distance rules of §5.8; k_mod/kdef of board type | |
| Nail plates (Nagelplatten), punched-plate connectors | EN 912 + abZ/ETA | truss plates factory only; plate γM 1.25; approved type tables (e.g. 120/10 → 12.5 kN up to 240/22 → 31.8 kN characteristic, with group-reduction by screwed-in pairs; "predominantly static only, wood moisture limit") — approval validity expired in the digest source — re-check current ETA/abZ |
Glued connections (Geklebte Holzverbindungen, EN 1995-1-1 §10, Neuhaus p.301-305) — when member continuity is glued rather than mechanically jointed:
- Schäftung (scarf joint): glue-face slope ≤ 1/10 (α ≤ 5.7°); thin
members/veneers only; MC ≤ 15 % at gluing (Δu ≤ 4 % between the two parts); NKL1+2 only.
- Keilzinkung (finger joint), two forms: ordinary lamella joints (finger
length ℓ_j ≥ 10 mm, typ. 15/20/30 mm, flank angle α ≤ 7.1°, strength reduction factor ν ≤ 0.18 → effective section A_ef = (1−ν)·A) used inside glulam/Balkenschichtholz/finger-jointed-solid laminations — glulam with ordinary lamella finger joints may be used in all 3 NKL; and "Universal" full-cross-section splices (ℓ_j ≥ 45 mm) used at frame corners (below) and full-depth member splices — Balkenschichtholz and full-section Universal finger joints are NKL1+2 only. Never place a full-section finger splice, or a Balkenschichtholz member of any kind, in continuously-wet (NKL3) exposure.
Frame corners (Rahmenecken) — moment-resisting corner joints, currently the biggest geometric gap for portal-frame/haunch FreeCAD detailing (Neuhaus p.663-671, Tab. 17.14-17.16):
- Dowelled (verdübelte) corners: per-dowel force from the corner moment
F_M,Ed = M_d·r/(n·r²) on a single dowel circle, or M_d·r_1/(n_1·r_1²+n_2·r_2²) on a double circle, vector-superposed with the axial/shear share and checked against F_v,Rd (§5.1-5.3); a double dowel-circle loses 15 % per-dowel capacity (n_ef factor 0.85) unless a splitting reinforcement (Ecksicherung) is added, in which case n_ef = 1.0 — size the reinforcement for a tie force equal to the outer circle's 30°-sector shear share. Corner-specific min. spacings (no equivalent in the general §5.2 table): within-circle ≥ 6d, between circles ≥ 5d, to end grain ≥ 7d (≥ 80 mm), to loaded/unloaded edge ≥ 3d. Avoid positive corner moments (high transverse tension); brace the inner corner against the compression-zone LTB failure mode (Kopfband).
- Finger-jointed (keilgezinkte) corners: interaction check
f_c,0,d/f_c,α,d·(σ_c,0,d/(k_c·f_c,0,d) + σ_m,d/f_m,d) ≤ 1 for a negative corner moment, but ≤ 0.2 only for a positive moment (transverse tension at the joint is the governing risk); f_c,α,d taken from the angle-dependent Versatz compression table (§5.10) using the glulam grade values; net section at the joint = 80 % of gross (20 % finger-joint reduction); GL28 and higher: ft,0,d/fc,0,d/fm,d further reduced 15 % (knot risk near the joint); NKL1+2 only, no exterior exposure. Joint angle α = β/2 (single zinking) or β/4 (double zinking), β = 90°−γ (γ = frame corner opening angle).
Section 4: Timber member design (verification chains)
All checks in the form σ/τ ≤ f_d (utilization = action-effect / resistance ≤ 1.0). Design values: f_d = k_mod·f_k/γ_M (γ_M = 1.3). Cross-section gross/net per EN 1995-1-1 §5.2 (weakenings: deduct notches/screw groups in tension; compression with small eccentricity may ignore local weakening outside the middle third).
4.1 Tension parallel to grain (Zug)
σ_t,0,d = F_t,d / A_net ≤ f_t,0,d (A_net = (b−weakening)·h)size increase k_h — see §3.4 for the correct, product-split formula: solidtimber k_h = min[(150/h)^0.2; 1.3] (worked C24 14/14 → 1.014); glulamk_h = min[(600/h)^0.1; 1.1]connection: σ on net section through the fastener line; net-section deductionby fastener type (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.557, Tab. 15.1):nails ΔA ≈ 0.10·A; bolts/dowels/fit bolts ΔA ≈ 0.15·A; ring/shear-plateconnectors ΔA ≈ 0.25·A; single traditional scarf (Versatz, §5.10) ΔA ≈ 0.25·A.Staggered-hole 50 %-of-spacing rule not confirmed against this source —VERIFY EN 1995-1-1 §5.1.3 directly.
Worked (C24 14/14, F_t,g=50 + F_t,s=50 kN): F_d = 1.35·50+1.5·50 = 142.5 kN (governs: compare F_d/k_mod: 142.5/0.9 = 158 vs snow-only 67.5/0.6 = 112); A_net = 157.6 cm² (bolt holes); f_t,0,d = 1.47·0.9/1.3 ≈ 1.02 → utilization 0.89 ✓.
4.2 Compression parallel + buckling (Druck, Ersatzstab)
λ = L_cr / i (rectangle: i = 0.289·h about the axis; weak axis governs)λ_rel = (λ/π)·√(f_c,0,k / E_0,05)k_c = 1 / (k + √(k² − λ_rel²)), k = 0.5·[1 + β_c·(λ_rel − 0.3) + λ_rel²]β_c = 0.2 (solid timber) ; 0.1 (glulam, LVL) [CORRECTED — product-dependent imperfection factor, not the earlier fixed "0.1·λ+0.3·λ²" form;Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.583-584, Tab. 16.6]σ_c,0,d ≤ k_c · f_c,0,d
Effective (buckling) length l_ef — reference table (Neuhaus p.588-593, Tab. 16.10, digesting NCI NA.13.2 Tab. NA.24): Euler cases as usual — fixed-free β=2, pinned-pinned (Pendelstütze) β=1, fixed-pinned β=0.707, fixed-fixed β=0.5, l_ef=β·L. Truss members: chords take the system-line (node-to-node) length unless a refined buckling check is done; web/diagonal members take the system-line length out-of-plane, a pin-dependent length in-plane. 2-/3-hinge arches/frames and elastic-spring-base columns have their own β_R/β_S expressions (function of E·I, N, spring stiffness K_φ) — read the table directly for these, not worth digesting a formula here. A frame corner modelled as an elastic (not rigid) spring adds a moment M = N·h/6·(1/k_c − 1) at the column head — include this if the corner stiffness (§3.7 Rahmenecken) is less than fully rigid. Worked (GL28c 16/32, L = 5 m pinned, F_d = 180 kN permanent → k_mod 0.6, f_c,0,d = 0.6·2.4/1.3 = 1.11 kN/cm²): y-axis λ = 500/(0.289·32) = 54 → λ_rel 0.826 → k_c 0.883 → util 0.36; z-axis λ = 108 → λ_rel 1.65 → k_c 0.341 → util 0.93 governs ✓. Rules: weak axis controls; section check only for weakenings in the compressed zone outside the middle third (then net area + second-order from eccentricity). Intermediate restraint between parallel beams (purlins/bracing) shortens L_cr about the weak axis — show restraint points on the model.
4.3 Bending + lateral torsional buckling (Biegung, Kippen)
σ_m,d = M_d / W_y ≤ k_crit · f_m,deffective laterally unrestrained length l_ef (fork supports, top-flange load):exact (NA effective-length formula): l_ef = a·√( a1·(1 + a2·(a_z/a)·√(B/T)) )B = E_d·b³h/12 ; T ≈ G_d·b³h/3 (G_mean/γ_M ≈ 50 kN/cm²); a_z = loadheight above shear centre (top edge a_z = +h/2, centre 0, bottom −h/2)a1, a2 from support/loading table (UDL fork: 1.13 / 1.44)simplified: l_ef = 0.9·L + 2·h (use the smaller)i_m = √(I_z·I_tor)/W_y (I_tor = a1'·b³h, a1' from h/b table; rectangularsections: i_m simplifies to b²/h)λ_rel,m = (l_ef/(π·i_m))·√(f_m,k/E_0,05) — **glulam only: multiply theproduct E_0,05·G_05 by 1.4 before taking the root** (NCI zu 6.3.3(2) Anm.1,Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.630); this lowers λ_rel,m(raises k_crit) materially for BSH beams — omitting it under-predicts LTBcapacity of every glulam beam check.k_crit = 1.0 (λ_rel,m ≤ 0.75) ; 1.56 − 0.75·λ_rel,m (0.75 < λ_rel,m ≤ 1.4) ;1/λ_rel,m² (λ_rel,m > 1.4)[CORRECTED thresholds and 3rd-branch form — was 0.2/1.1/"1.11/λ_rel²?";confirmed against the book's own numeric verification table, Neuhausp.630-632, Tab. 17.3/17.4]
l_ef (Kipplänge) exact NA formula — extraction of this specific equation was unreliable (repeated √-symbol loss in both this digest and the new source); do not trust either version blindly, re-derive from EN 1995-1-1/NA NCI NA.13.3 Table NA.25 directly before a governing LTB check. The a1/a2 coefficient table, however, is independently confirmed (Neuhaus p.640-641, Tab. 17.9/17.10) and safe to use as printed: fork-supported single span, UDL → a1/a2 = 1.13/1.44 (matches the worked example below); constant moment → 1.77/0; point load at midspan → 1.35/1.74; cantilever UDL → 1.27/1.03, tip load → 2.05/1.50; fixed-fixed → 6.81/0.40 or 5.12/0.40; continuous-beam midspan → 1.70/1.60 or 1.30/1.60. Worked (GL28c 16/90, L = 15 m, q_d = 12.4 kN/m, restraint at ends + mid-thirds, a = 5 m, top-edge load): W = 21 600 cm³, M = 348.8 kNm → σ = 1.61 kN/cm²; f_m,d = 0.9·2.8/1.3 = 1.94; single bending util 0.83 ✓. LTB: l_ef = 618 cm (exact) < 630 (simple) → use 618; i_m = 2.68 cm; λ_rel,m = 0.856 → k_crit 0.918 → util 0.91 governs → the beam is kip- (LTB-) critical, not strength-critical: add restraint or increase b. Bearing pressure at the 20 cm support with k_c,90 = 1.75 (glulam, single support) and A_c,ef = (3+20+3)·16 = 416 cm² → util 0.74 ✓.
Bracing/fly-brace forces for the restrained compression edge (EC5-specific refinement of the generic "1-2 % bracing force" rule of thumb — Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.870-873, Tab. 26.4/26.5): individual restraint (fly-brace) design force F_d = N_d/50 (solid timber, Balkenschichtholz) or N_d/80 (glulam, LVL), where N_d = (1−k_crit)·M_d/h is the destabilising force at the restraint; distributed bracing-system load q_d = k_ℓ·n·N_d/(30·l), k_ℓ = min(1, √(15/l)) (l in m); permissible in-plane deflection of the bracing system u ≤ l/500; minimum restraint spring stiffness C = 4·N_d/a (a = restraint spacing). Use this instead of the generic 1-2 % figure whenever the member and its k_crit are already known from the LTB check above.
4.4 Shear (Schub) with cracked section
τ_d = V_d·S/(I·b) ≤ f_v,d; rectangle τ = 1.5·V/(b_eff·h)cracking at interior supports/continuous beams: b_eff = k_cr·bTake V at h from support face where bearing is direct.
k_cr by product (CORRECTED/complete — NDP zu 6.1.7(2), Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.685, Tab. 18.1):
| Product | k_cr | |
|---|---|---|
| Solid softwood (Nadelvollholz) | 2.0/f_v,k | |
| Balkenschichtholz aus Nadelholz (duo/trio) | 2.0/f_v,k (paired with solid softwood, NOT glulam) | |
| Glulam (Brettschichtholz) | 2.5/f_v,k (worked below: 2.5/3.5 = 0.714) | |
| CLT (Brettsperrholz) | 1.0 | |
| Solid hardwood (Laubvollholz) | 0.67 (fixed value, not a formula) | |
| Other wood-based products (LVL etc., EN 13986/14374) | 1.0 |
Solid-softwood-only bonus: k_cr may be increased 30 % in zones ≥ 1.5 m from the end grain (shrinkage cracks concentrate near member ends) — not permitted for glulam; can meaningfully relax an over-conservative shear check away from bearing zones in solid joists/rafters. Worked (same GL28c beam): k_cr = 2.5/f_v,k = 0.714 → b_eff = 11.4 cm; f_v,d = 0.9·0.35/1.3 = 0.242 kN/cm²; τ = 1.5·93/(11.4·90) = 0.136 → util 0.56 ✓ (0.49 with V reduced at h from face).
4.5 Bearing perpendicular to grain (Flächenpressung ⊥ Faser)
σ_c,90,d = F_c,90,d / A_c,ef ≤ k_c,90 · f_c,90,d
k_c,90 (CONFIRMED against Wendehorst Tab. — DIN EN 1995-1-1/NA 6.1.5), by support condition and product — default is 1.0 for any l_1 < 2h:
| Product | l_1 < 2h (default) | l_1 ≥ 2h, continuous support (Schwellendruck) | l_1 ≥ 2h, single/discrete support (Auflagerdruck) | |
|---|---|---|---|---|
| Hardwood solid (Laubvollholz) | 1.0 | 1.0 (no elevated value) | 1.0 | |
| Softwood solid (Nadelvollholz) | 1.0 | 1.25 | 1.5 | |
| Glulam, softwood (BSH aus Nadelholz) | 1.0 | 1.5 | 1.75 (also applies for bearing length > 400 mm) | |
| Truss node, indirect connection | — | — | 1.5 (NA 6.1.5, all products) |
(Corrects the earlier flagged guess: hardwood does not get an elevated k_c,90 — it stays at 1.0. The worked example's 1.25 solid-continuous / 1.75 glulam-single values were both right.)
A_c,ef = (3 + l_bearing + 3)·b [cm] load spreading 3 cm each side along grainedge distance a > 3 cm each side required for spreading; otherwise A = b·l
Worked (post C24 8/12 on sill, F_d = 20.25 kN permanent, k_mod 0.6): f_c,90,d = 0.6·0.25/1.3 = 0.115 kN/cm²; A_ef = (3+12+3)·8 = 144 cm²; 20.25/144 = 0.141 ≤ 1.25·0.115 = 0.144 → util 0.98 ✓ (tight — this is the classic hidden failure; widen the bearing plate).
4.6 Biaxial bending
σ_my/f_my,d + k_m·σ_mz/f_mz,d ≤ 1.0 with k_m = 0.7 (one-axis plast.redistribution possible) or 1.0 (conservative alternative, symmetric)work: purlin GL24h 18/36: k_m = 0.7 → util 0.84 + 0.7·0.16 = 0.95 ✓;k_h (bending about y, h < 60? → (60/36)^0.1 = 1.052) and k_ℓ = 1.2 (flat/edgeuse ≥ 4 lamellae) applied to the respective f_m,d.
4.7 Combined axial + bending (simplified NA "Ersatzstab" chain)
(σ_c/σ_c,crit,y)² + σ_my/(f_m,y,d·(1−σ_c/σ_crit,y))+ (σ_mz/(f_m,z,d·(1−σ_c/σ_crit,z)))² ≤ 1(EN 1995-1-1 6.2.1 + 6.3; tension + bending drops the first term; use the fullNA formulas or software for anything close to 1.0 — VERIFY form per edition.)
4.8 Serviceability — deflection (Biegung GZG)
w_final = w_g,perm·(1 + k_def) + w_g,qp? + Σ w_q,i·(1 + ψ_2,i·k_def)net (against camber w_c): w_net = w_final − w_cworked GL28c L=15 m, k_def 0.6 (CL1), ψ2 snow = 0:w_inst,g = 2.71 cm ≤; w_inst = 4.74 ≤ l/200 = 7.5 (0.63)w_fin = 4.34 + 2.03 = 6.37 ≤ l/150 = 10 (0.64)w_net,fin = 4.34 − 4.0 = 0.34 ≤ l/250? = 6.0 (0.06) ✓deflection limits (CORRECTED — NDP zu 7.2(2), Neuhaus, Ingenieurholzbau, 4thed. 2017, p.848, Tab. 25.4; classified by member importance/camber status,**not** by "brittle finishes present" — that split is an old DIN 1052-eraconcept, not what the current NA table actually uses):general members: w_inst ≤ l/300, w_net,fin ≤ l/300, w_fin ≤ l/200(cantilever: l_k/150, l_k/150, l_k/100)cambered/secondary members (überhöhte Bauteile; agricultural buildings;Sparren/Pfetten rafters+purlins): w_inst ≤ l/200, w_net,fin ≤ l/250,w_fin ≤ l/150 (cantilever: l_k/100, l_k/125, l_k/75)
Vibration (floors, EN 1995-1-1/NA §7.3.3) — three-part check, f1 > 8 Hz floors (replaces the earlier a(n)-curve digest, which reflected a different/ older method; Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.854-858):
- Stiffness: w/F ≤ a [mm/kN] under a 1 kN point load; recommended
0.5 ≤ a ≤ 1.5, a = 1.0 as default.
- Frequency: f1 = k_f·(π/2l²)·√((EI)_ℓ/m) > 8 Hz (k_f from a continuity
table, = 1.0 for a single span).
- Velocity response: v ≤ b·(f1·ζ)⁻¹, with a tabulated a↔b linkage
(anchor points: a=0.5→b=150 … a=1.5→b=100 … a=4.0→b=50, interpolate for intermediate a; ζ = 1 % default damping — read the NA table for the exact curve, these are anchor points not a formula). Long-span timber floors almost always need closer joists, a deeper section, or a structural topping to pass check 3.
4.9 Notched ends and perpendicular tension (Ausklinkung)
notched shear (support/loaded side, sloped notch): τ_d ≤ k_v·f_v,d withk_v = min{1 ; k_n·(1+1.1·i^1.5/√h) / [√h·(√(α(1−α)) + 0.8·(x/h)·√(1/α−α²))]}(square notch: drop the i-term); k_n = 5.0 (solid timber) / 6.5 (glulam) /4.5 (LVL/Furnierschichtholz); α = h_ef/h; x = distance from support reactionline to the notch corner; i = notch-slope ratio (0 for square notch)[Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.743, Tab. 21.1 — kn values andformula structure confirmed, incl. the previously-missing LVL value 4.5]top-side (unloaded-edge) notch: k_v = 1 by default; if the load point fallswithin h_ef of the notch, k_v = (h/h_ef)·[1 − (h−h_ef)·x/(h·h_ef)] insteadtransverse tension force (CORRECTED — was structurally wrong):F_t,90,d = 1.3·V_d·[3(1−α)² − 2(1−α)³] [Neuhaus p.746, Tab. 21.2]practice: unreinforced notches NKL1-2 only; NKL3 always requiresreinforcement
Worked (GL28h 14/110, h_ef = 90, V_d = 120 kN): un-notched util 0.88 ✓; notched k_v = 0.358 → util 2.6 → fails → reinforcement required; F_t,90 = 13.6 kN → glued-in M10 4.8 bars (2 near faces, l_ad = 200 mm, bond line f_g,k = 4.0 N/mm², F_t,Rd = 0.9·A_s·f_u,k/1.25 = 16.7 kN/bar → 2 bars util 0.41 ✓) or full-threaded screws Ø8×600 (pull-out 19.6 kN? govern shank tension 17.0 kN, n_eff = 1.87 → util 0.69 ✓); with reinforcement k_v → 1.0 → util 0.93 ✓. Detailing rule: ≥ 2 reinforcement elements near the edges; bar diameter ≤ 20 mm; effective bond length ≤ 8·d? (worked used 200 mm) — VERIFY ETA values.
Notching design principles (traditional Zimmerer rules + EN 1995-1-1 6.1.5):every notch creates (a) a shear bottleneck, (b) a splitting risk (σ ⊥ grain),(c) a lever for horizontal tie. Keep notches shallow and far from mid-span;avoid re-entrant corners (drill relief holes); rule of thumb h_ef/h ≥ 0.6 forun-reinforced — VERIFY per case.
4.10 Holes through beams (Durchbrüche) — glulam/LVL only
Genuinely new geometric ruleset (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.751-753, Tab. 21.3, digesting NCI NA.6.7) — the correct reference for sizing/placing a service duct penetration through a glulam or LVL roof binder/floor beam. Applies only to rectangular glulam or LVL beams, hole clear dimension d > 50 mm (smaller holes are ordinary local weakening per §8.3.3, ignore this ruleset).
Geometric limits: end-distance from support l_v ≥ h; hole-to-hole spacing l_z ≥ 1.5h and ≥ 300 mm; hole-to-point-load distance l_A ≥ h/2; edge margin top/bottom h_ro, h_ru ≥ 0.35h each (i.e. hole confined to the central 30 % of the depth); rectangular-hole length a ≤ 0.4h; hole height h_d ≤ 0.15h.
Transverse tension check (the hole splits the beam locally, same failure mode as a notch): F_t,90,d = F_t,V,d + F_t,M,d, with F_t,V,d = (V_d·h_d/4h)· (3−h_d²/h²) (use 0.7·h_d in place of h_d for round holes) and F_t,M,d = 0.008·M_d/h_r; check against 0.5·l_t,90·b·k_t,90·f_t,90,d.
NKL1-2 unreinforced only; NKL3 always needs reinforcement (same logic as notches, §4.9). Directly usable in a FreeCAD/BIM model to validate where an MEP duct or cable route is allowed to cross a glulam member without a strengthening detail.
Section 5: Timber connections (Verbindungen)
5.1 The yield model (Eurocode 5, "Y-Modell") for dowel-type fasteners
Every nail/screw/dowel/bolt is a beam in two embedments; characteristic single-shear capacity (simplified, α = 0):
f_h,k = 0.082·(1 − 0.01·d)·ρ_k [N/mm²] (ρ in kg/m³, d in mm)f_h,α,k = f_h,0,k / (k_90·sin²α + cos²α); k_90: softwood 1.35 + 0.015d,hardwood 0.90 + 0.015d, LVL 1.30 + 0.015dM_y,Rk = 0.3·f_u,k·d^2.6 — CORRECTED: applies uniformly to dowels, boltsAND nails (round-shank nails factor 0.3, profiled/square-ish-shank nailsfactor 0.45). The elastic-section-modulus form "f_u,k·d³/6" does notappear in EC5's simplified method at all — it is DIN 1052 (superseded)leaking into the earlier digest. [Neuhaus, Ingenieurholzbau, 4th ed. 2017,p.413, Tab. 11.3]f_u,k (N/mm²): dowel S235/S275/S355 → 360/410/470 (p.413); bolt/threaded-rodproperty class 4.6/4.8/5.6/5.8/8.8 → 400/400/500/500/800 (p.425, Tab. 11.9);nail/wire ≥ 600γ_M = 1.1 for bending-stressed dowel-type fasteners — derived as the"worst-case envelope" combining γ_M,Steel=1.1 and γ_M,Holz=1.3 through thek_mod reconciliation (p.407, Gl. 11.19/11.20); this is the basis for theγ_M used throughout §5.1-5.6, but does NOT apply to ring/shear-plateconnectors (§5.7 uses γ_M=1.3 — different failure mode, wood embedmentgoverns there, not steel bending).F_v,Rk = √(2β/(1+β))·d·√(2·M_y,Rk·f_h,1,k) single shear; β = f_h,1/f_h,2for dissimilar members; double shear: middle-member factor on F_v,Rkembedment: side t_1,req = 1.15·√((2β/(1+β))·M_y,Rk/f_h,1,k) + d/2middle t_2,req = 1.15·√(M_y,Rk/(4·f_h,1,k)) + d/2(worked: Ø12 S235 dowel in C24 → F_v,Rk 6.08 kN/shear plane; t_req 58 mm)
5.2 Minimum spacing and edge distances (dowels/bolts, EN 1995-1-1 T8.2/T8.4)
CORRECTED — the a₁/a₂ rows have NO tension/compression split; only a₃/a₄ do (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.416, Tab. 11.5, EC5 Tab. 8.5, for Stabdübel/Passbolzen — d = fastener diameter, α = load-to-grain angle, 0-360° unless noted):
| Spacing | Formula | |||
|---|---|---|---|---|
| a₁ (parallel to grain, all α) | (3 + 2·\ | cos α\ | )·d | |
| a₂ (perpendicular, all α) | 3·d (no angle dependence) | |||
| a₃,t (loaded end, −90°≤α≤90°) | max(7d; 80 mm) | |||
| a₃,c (unloaded end, 90–150° & 210–270°) | a₃,t·\ | sin α\ | ||
| a₃,c (unloaded end, 150–210°) | max(3.5d; 40 mm) | |||
| a₄,t (loaded edge, 0–180°) | max[(2+2·sin α)d; 3d] | |||
| a₄,c (unloaded edge, 180–360°) | 3·d |
(worked Ø12 example: a₁ 60 → 71 provided; a₂ 36 → 50; a₃,t 84 → 99 ✓.)
Bolts and threaded rods use a separate, larger table (Neuhaus p.427, Tab. 11.12, EC5 Tab. 8.4) — do not reuse the dowel table above for bolts: a₁ = (4+\|cos α\|)d; a₂ = 4d; a₃,t = max(7d; 80 mm); a₃,c = (1+6·sin α)d [90–150°] / 4d [150–210°] / (1+6·\|sin α\|)d [210–270°]; a₄,t = max[(2+2·sin α)d; 3d]; a₄,c = 3d.
5.3 Effective number of fasteners n_ef (group effect)
parallel to grain (α=0): n_ef = min[ n ; n^0.9·⁴√(a₁/(13·d)) ] — CORRECTED:fourth root, and n raised to the 0.9 power (not "0.9·n·√(...)"); workedcheck n=3, a₁=71, d=12 → n^0.9=2.688, (a₁/13d)^0.25=0.821 → n_ef=2.21 ✓matches the pre-existing worked number exactly [Neuhaus, Ingenieurholzbau,4th ed. 2017, p.415, Gl. 11.21a]perpendicular (α=90°): n_ef = n — CORRECTED: full count, no reduction(no splitting risk perpendicular to grain), NOT "min(n; n^0.9)"0° < α < 90°: linear interpolation between the α=0 value above and n_ef=n(the earlier "45° → 1.77" worked number could not be reconciled againstany plausible input combination — treat as unresolved, don't reuse it)nails: n_ef = n·k_ef, k_ef = 1.0 (a₁≥14d) / 0.85 (a₁=10d) / 0.7 (a₁=7d) /0.5 (a₁=4d, pre-drilled only) — CONFIRMS the tier grid exactly, now withthe a₁-thresholds attached [Neuhaus p.438, Tab. 11.16]ring/shear-plate connectors have their own n_eff rule — see §5.7aF_v,Rd = k_mod·n_ef·F_v,Rk/γ_M (simplified γ_M = 1.1 — see §5.1 basis)
5.4 Nails (Nägel, EN 14592 + EN 10230-1)
- Shank: ductile wire, f_u,k ≥ 600 N/mm². Never design a nail for pull-out
as the primary load path (withdrawal is a real, code-checkable capacity in EC5, unlike screws it just shouldn't be relied on for a primary connection): CORRECTED — the "N per mm penetration" framing was itself a misdigest; EC5's real method is density-quadratic, not a diameter lookup (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.453-454, Tab. 11.23): smooth-shank f_ax,k = 20×10⁻⁶·ρ_k² [N/mm²]; head pull-through f_head,k = 70×10⁻⁶·ρ_k²; profiled/special nails (3 load-bearing classes) f_ax,k = 30/40/50×10⁻⁶·ρ_k²; head pull-through classes A–F (resolves the "classes A-F lost in extraction" flag): f_head,k = 60/80/100/120/140/160 ×10⁻⁶·ρ_k² respectively. F_ax,Rk = min{f_ax,k·d·t_pen ; f_ax,k·d·t + f_head,k·d²_h} (smooth) or min{f_ax,k·d·t_pen ; f_head,k·d²_h} (profiled).
- Characteristic single-shear R_k: 320 N (18 mm) up to ~4120 N (long profile
specials), un-predrilled vs predrilled sets differ — digest grid garbled, read EN 14592/manufacturer tables. Worked 3.4×90 (f_u,k 600, C24): F_v,Rk = 765 N/shear plane; group n_ef = 29.44/side → F_v,Rd (k_mod 0.6, γ_M 1.1) = 12.3 kN; util 0.95 ✓.
- Penetration rule: t ≥ 9d for full capacity (round nails; profiled nails
6-8d); 4d < t < 9d → F_v,Rk,red = F_v,Rk·t/(9d) — CONFIRMED linear; t < 4d not permitted [Neuhaus p.~448].
- Pre-drill when t < max(7d; density term) — split-prone species (spruce):
t < max(14d; (13d−30)·ρk/200) → drill; edge a₄ ≥ 10d (ρk ≤ 420) / 14d (420 < ρk ≤ 500); nail across grain into side faces, never into end grain; min member thickness 24 mm (worked). Spacing (un-pre-drilled, ρk ≤ 420, d < 5): a₁ = (5+5cosα)d; a₂ = 5d; a₃,t = (10+5cosα)d; a₄,t = (5+2sinα)d; a₄,c = 3d. Diagonal nailing carries NA reductions (−25 %? — VERIFY); nails from both sides in one plane need ≥ 4d overlap.
5.5 Structural screws (Holzschrauben) and glued-in rods
- **Withdrawal — CORRECTED formula (the earlier
k_1·d²·(ρ_k/350)^0.8form
does not appear in this book edition and is likely a fragment of a different/draft source): (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.475-476, Tab. 11.28, EC5 §8.7.2, for 6≤d≤12mm, 0.6≤d₁/d≤0.75): `f_ax,k = 0.52·d^(−0.5)·l_ef^(−0.1)·ρ_k^0.8` [N/mm²]; `k_d = min(d/8, 1)`; `F_ax,α,Rk = (n_ef·f_ax,k·d·l_ef·k_d) / (1.2·cos²α + sin²α)`. Head pull-through: `F_ax,α,Rk = n_ef·f_head,k·d_h²·(ρ_k/ρ_a)^0.8`. Steel tension (governs when the head/withdrawal don't): `F_t,Rk = n_ef·f_tens,k` with `f_tens,k = 300·π·d₁²/4` [N] (d₁ = core/thread-root diameter) — a concrete formula replacing the earlier bare worked number. n_ef = n^0.9 (confirmed). Spacing (Neuhaus p.477-478, Tab. 11.29): a₁ = 7d (row spacing along grain), a₂ = 5d, a₁,CG = 10d (end distance to thread centroid — corrects the earlier "a₃,c ≥ 5d", which used the wrong label and value), a₂,CG = 4d (edge distance, corrects "a₄,c ≥ 4d" label), t ≥ 12d. Screws take withdrawal design forces**; nails do not. Torque window matters — over-torque crushes fibres.
- Full-thread screws (Vollgewindeschrauben) — book's own preface names
this a major new-edition topic; no generalized EC5/NA design table exists — capacity is entirely ETA/abZ-bound per product (matches the existing framing below). Qualitative guidance worth applying in a FreeCAD detail even without a numeric table (Neuhaus p.479-496): a full-thread screw placed perpendicular to grain behind a "thick" fastener group lets n_ef = n be taken without the §5.3 reduction, sized to carry roughly 30 % of the fastener group's design load in withdrawal; inclined/crossed screw pairs transferring axial tension at a member-to-member joint must be angled so each screw is in tension, not compression (wrong inclination reverses this); misplacing the crossing point in a main-beam/secondary-beam joint induces unintended torsion in the connection — model the crossing point deliberately, don't let it fall wherever geometry is convenient.
- Glued-in threaded bars (Eingeklebte Gewindestangen) — **CORRECTED: this
is NOT purely ETA-bound; the bond strength has a National-Annex-normed, length-dependent formula (Neuhaus p.324, Tab. 7.11, DIN EN 1995-1-1/NA NCI NA.6.8.5, Tab. NA.12): l_ad ≤ 250 mm → f_k1,k = 4.0 N/mm² (matches the earlier digest value, but only in this length band); 250 < l_ad ≤ 500 mm → f_k1,k = 5.25 − 0.005·l_ad; 500 < l_ad ≤ 1000 mm → f_k1,k = 3.5 − 0.0015·l_ad. γ_M,H = 1.3; f_k1,d = k_mod·f_k1,k/γ_M,H. Design: F_ax,Rd = min{f_y,d·A_ef ; π·d·l_ad·f_k1,d}; the NA explicitly recommends sizing so the steel governs (F_ax,S,Rd < F_ax,F,Rd) for a ductile, non-brittle failure mode. l_ad,min = max(0.5·d² , 10·d) mm; max effective wood tension area per rod A_ef,max = 36·d²**. (Surface-bonding variants: f_k2,k = 0.75 N/mm² FRP, f_k3,k = 1.50 N/mm² steel plate — same table, different application.) The bar-diameter/pre-drill/edge-distance parameters remain ETA-bound as before — only the bond-strength formula is now normative rather than a single flagged digest value.
5.6 Bolts and dowels (Schrauben, Stabdübel, Passschrauben)
- Steel grades S235/S275/S355 dowels; M-threads property classes 4.6-8.8
(f_u,k 400-800); threaded rod 5.8. Yield model §5.1 with M_y = f_u·d³/6.
- Washers/plates — CORRECTED sequence (Neuhaus, Ingenieurholzbau, 4th ed.
2017, p.427, Tab. 11.11, DIN 1052:2008-12 Anhang G.3.4 preferred sizes; general sizing rule EC5 §10.4.3: d_a ≥ 3d, s ≥ 0.3d): M12→Ø58, M16→Ø68, M20→Ø80, M22→Ø92, M24→Ø105 — the earlier digest kept the right diameter progression but wrongly labelled it M12/16/20/24/30: the real table stops at M24 and the second-to-last size is M22, not M24; there is no M30 row. Thickness s = 6 mm (M12/M16), s = 8 mm (M20/M22/M24); inner diameter 14/18/22/25/27 mm. Purpose: spread head/nut pressure f_h,d, prevent embedment losses on shrinkage; re-tension after drying shrinkage of members loaded across the bolt group.
- Bolts are SL-analogues (bearing after slip); in timber they need big plates
because wood crushes ⊥ grain under nuts. End-grain bearing of a bolt is fine; loading the timber in bearing ⊥ grain at the plate is the check.
5.7 Ring and shear-plate connectors (Ring-/Scheibendübel, EN 14566 types
A/B; toothed plate types C)
Diameters and base capacity — CORRECTED (the earlier Ø grid was fabricated/from a mismatched catalogue). Real product sizes (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.510-511, Tab. 12.6, DIN EN 1995-1-1:2010-12 §8.9): Type A1 (Ringdübel, two-sided) Ø 65, 80, 95, 126, 128, 160, 190 mm; Type B1 (Scheibendübel, one-sided) Ø 65, 80, 95, 128, 160 mm. The earlier diameters 50/75/117/140/165 do not exist in this table — drop them.
Characteristic resistance per unit, per shear plane, ρ_k = 350, k_i = 1.0 (N):
| Ø | 65 | 80 | 95 | 126 | 128 | 160 | 190 | |
|---|---|---|---|---|---|---|---|---|
| A1/B1 | 18 300 | 25 000 | 32 400 | 49 500 | 50 700 | 70 800 | 91 700 |
No separate ρ_k = 420 table exists — density is a single multiplicative factor k₃ (below), monotonically non-decreasing with ρ_k, so higher density can never lower capacity; the earlier "ρk=420" row with cells sometimes below the ρk=350 row was a fabrication/misalignment artifact — discard it.
Base formula (constants confirmed): F_v,0,Rk = min{k1·k2·k3·k4·35·d_c^1.5 ; k1·k3·31.5·d_c·h_e} (worked A1-Ø65, h_e≈15mm: min(18.34; 30.7) = 18.3 kN ✓).
k1-k4 factors — CORRECTED (Neuhaus p.509-510):
- k1 (thickness) = min{1 ; t1/(3·h_e) ; t2/(5·h_e)} — a continuous ratio,
not a binary "t ≥ t_min+h_e" cutoff.
- k2 (end distance, −30°≤α≤30°) = min{k_a ; a₃,t/(2·d_c)}, k_a = 1.25
(single connector/shear plane) or 1.0 (multiple); k2 = 1.0 outside that α range.
- k3 = min{1.75 ; ρ_k/350} (confirmed as before).
- k4 is NOT a direction factor — it is a material-pairing factor: k4=1.0
timber-timber, k4=1.1 steel-plate-timber. Angle/direction dependence is handled separately: F_v,α,Rk = F_v,0,Rk/(k₉₀·sin²α+cos²α), k₉₀=1.3+0.001·d_c.
Spacing / edge distances (d_c = connector Ø): a₁ = (1.2 + 0.8·|cos α|)·d_c; a₂ = 1.2·d_c; a₃,t = 2.0·d_c; a₃,c = (0.4+1.6·|sin α|)·d_c [90-150°, 210-270°] / 1.2·d_c [150-210°]; a₄,t = (0.6+0.2·|sin α|)·d_c; a₄,c = 0.6·d_c (worked check: 130<150; 78<80; 130<150; 39<60 ✓ — matches the earlier a₁/a₂/a₃,t/a₄,c figures, now with the previously-missing a₃,c/a₄,t angle forms added).
γ_M = 1.3 for ring/shear-plate connectors — CONFIRMED decisively as the book's own consistently-used value (p.510, Gl. 12.3), a different row from the dowel-type-fastener bending value (γ_M=1.1, §5.1) because failure here is governed by wood embedment/crushing, not steel bending. Never apply the §5.3 default γ_M=1.1 to ring/shear-plate connectors.
5.7a Ring connectors & surface dowels (Ringverbinder, Flächendübel /
Scheibendübel) — n_eff and worked design
Terminology: Ringdübel/Ringverbinder = ring connector; Scheiben-/Flächendübel = shear plate; toothed plate = type C (Tabelle 12.10/12.11, p.512-521 — diameter/h_e/capacity columns exist analogous to A1/B1 above but were not extracted in this pass; add if a Type-C project comes up).
Effective number n_eff (ring connectors parallel to grain — own rule, NOT the §5.3 dowel form) — CORRECTED formula:
n_eff = 2 + (1 − n/20)·(n−2) (2 < n ≤ 20; max 20 connectors/row)
[Neuhaus p.511, Gl. 12.5, Tab. 12.4] Lookup: n=1→1, 2→2, 3→2.85 (confirms the earlier worked digest), 4→3.60, 5→4.25, 6→4.80, 7→5.25, 8→5.60, 9→5.85, 10→6.00, 11→6.05 (peak), 12→6.00, …, 20→2.00 (symmetric decline). A row of 12 connectors gives n_eff = 6.00, not 11.4 — the earlier "4 groups → 11.4 of 12" combined two parallel rows of 6 (2×6.00=12.0, not a literal 4-group sum); re-derive any multi-row worked example from this table rather than reusing the old shortcut.
Worked tension splice (C30 ρ_k 380, 12× A1 Ø65 in two rows of 6, single shear, F_d 101.3 kN permanent, k_mod 0.6):
- spacing/edges ✓ (above);
- k3 = min(1.75; 380/350) = 1.086 → F_v,Rk = 18.3·1.086 = 19.9 kN per unit;
- F_v,Rd per unit = 0.6·19.9/1.3 (γ_M = 1.3, confirmed above) = 9.18 kN;
- n_eff per row of 6 = 4.80; two rows → n_eff,total = 9.60 → capacity =
9.60·9.18 = 88.1 kN → util 101.3/88.1 = 1.15 — fails at this row count/diameter; add connectors or step up to Ø80 (this re-derivation supersedes the earlier "0.97 ✓" result, which used the wrong n_eff). Detailing: matched rings on both faces (Gegenring), central bolt + DIN 440 plates, full clamping at assembly, re-tension after shrinkage (§5.6 logic).
Passholz / steel-plate pairing (practice note, not part of the table digest): every splice with a middle steel plate creates two shear planes per connector line — each timber face needs its own matched ring line and its own n_eff; a timber insert (Passholz) between steel plates is designed as an independent member (own edge distances, own bearing zone at the plate end); steel plate and bolt group to EN 1993 with the timber embedment governing; a₃,t end distance measured from BOTH facing elements.
5.8 Metal connector plates and standard detailing rules
- Nail plates (Nagelplatten): factory truss plates only; plate check γ_M
1.25; minimum member thickness; plate overlap at splices; no field nail-plating.
- Punched/embossed plate & angle connectors (abZ/ETA type tables): use
the approved characteristic values only; group reduction tables per approved pair count; predominantly static load + moisture limits per approval; the digest's example approval list was already expired — re-check.
- Framing principles from connection physics (EN-agnostic):
- shortest force path; axes aligned (2 members) or concurrent (≥ 3) —
eccentricity = unplanned bending;
- no acute angles between members (jam + splitting + no tool access);
- introduce point loads where the receiving member is stiff (axial into
end grain, not transverse into a thin edge);
- stagger (entflechten) fastener rows of adjacent layers; provide slip
capacity where shrinkage is expected (oversize/slotted holes);
- classify all 12 senses per joint (6 translations + 6 rotations) —
form-fit/material-fit/force-fit per direction, not "the joint is rigid";
- never rely on a compression joint whose compression can vanish
(uplift/shrinkage) — provide a tension route (strap, through-bolt);
- notch only where stress is low (near inflection points), never in the
tension zone.
- Typical joints (practice, EN-checkable): rafter-to-plate = designed
uplift strap + nails for position only; joist-to-beam = hanger with full manufacturer nail/screw pattern (a ledger strip alone is not a connection); beam-to-column pincer = twin beams, connectors at min edge distances with shear length in front of the group to stop splitting; slotted-in steel plate with dowels through the column; steel saddle (Sattelholz) at perpendicular compression.
- Corrosive pairing: copper-based preservatives attack plain steel — use
hot-dip galvanized (thick class) or stainless; aluminium against treated spruce corrodes: isolate.
5.9 Timber-to-steel and column-foot notes
Raise structural timber off the pedestal (see §6.2), isolate from masonry/concrete with a DPC under the sill, and take uplift with a hold-down on a designed anchor group (concrete-edge check → concrete-detailing); steel shoes and fork columns bear on plates sized for f_c,90,d with shear keys so anchors carry uplift only.
5.10 Traditional carpentry joints (Zimmermannsmäßige Verbindungen)
Not folklore — Versätze, Zapfen and Holznägel are normed under DIN EN 1995-1-1/NA:2013-08, NCI NA.12, with real design formulas (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.543-556, Ch.14 — confidence high on normative status, medium-high on exact constant transcription, light re-check recommended before publishing exact numbers). Relevant to heritage/exposed- timber-frame FreeCAD modelling where mechanical fasteners would be visually or historically wrong.
- Versätze (notched/step joints, p.543-551): compression-only —
decompose the force into normal (N_d) and diagonal (D_d) components and check bearing stress on the notch face; Stirnversatz (frontal notch), Fersenversatz (heel notch), Brustversatz variants. Always needs a secondary connection against sliding — a Versatz alone never resists tension or lateral slip.
- Zapfen (mortise-tenon, p.551-554), Tab. 14.2 (NCI NA.12.2): for beams
h ≤ 300 mm, shear capacity F_Rk = min{(1/k_z)·b_ef·h_e·k_z·k_v·f_v,k ; 1.7·b·l_z,ef·f_c,90,k} (checks both wood shear and end-bearing); own min/max tenon geometry table; own splitting/cross-grain-tension check (§4.10-style).
- Holznägel (oak dowels, p.554-556), Tab. 14.3: simple shear formula
F_Rk = 9.5·d² [N, d in mm], single or double shear; own (smaller than Stabdübel) spacing table, independent of grain direction.
Section 6: Timber durability — DIN 68800 use classes and constructional protection
6.1 Gebrauchsklassen (use classes, DIN 68800-1:2019-06)
| GK | Exposure | Examples | Moisture regime | |
|---|---|---|---|---|
| 0 | visible, dry interior, above ground | exposed interior columns/beams | ≤ ~12 % short-term wetting | |
| 1 | concealed/protected interior, above ground | rafters/beams under the roof covering (not GK0), interior walls | occasional condensation allowed | |
| 2 | interior against damp masonry; covered exterior with splash-water protection | old-building beam heads, covered bridges, carports | short wetting, slow drying | |
| 3.1 | above ground, permanent weather exposure; splash water at member feet | open facade members, fence posts with splash, balconies (damp) | frequent wetting | |
| 3.2 | as 3.1 but with water accumulation/stau or high organic attack | flat-hung boards, wet zones | long wetting | |
| 4 | permanent fresh-water contact | hydraulic structures, bank protection | saturated | |
| 5 | permanent seawater contact | piles, dikes, jetties | saturated |
Species natural durability (core/Kernholz unless noted): Fichte (spruce, no core) → GK 0; Kiefer (pine) core → 0-2; Lärche/Douglasie core → 0-3.1; Eiche core → up to 3.2; Buche → 0 only (not durable, never outside); tropical/very durable (teak, Afzelia) → up to 4; Azobé → 5; lapacho (Ipe) → 4. Sapwood (Splint) of all species is not durable → treat or avoid.
CONFIRMS this matrix against the primary source (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.220-221, Tab. 5.8, DIN 68800-1:2011-10 Tab. 5 — the table for which GK a species may be used in without chemical preservative): the species×GK assignments above are essentially correct as written. Refinements: plantation-grown teak is explicitly excluded from the GK4 allowance (natural-forest teak only); Azobé heartwood reaches GK5, Ipe heartwood GK4; Siberian larch (Larix sibirica, a distinct species from European larch) gets an extra allowance to GK3.2 if ρ > 700 kg/m³ (p.221, fn.8) — worth specifying explicitly since ordinary European Lärche/Douglasie tops out at GK3.1. Several allowances (Kiefer→GK2, Lärche/Douglasie→GK2/3.1) are empirical/practice-based exceptions under DIN 68800-1 §6.8.2.3, not a strength-of-durability-class argument — treat them as fixed rule-book entries, not something to extrapolate to an untested species.
⚠ VERIFY remains open: the preservative-class table (Iv/P/W/E hazardlevels, DIN 68800-3) was not found cleanly in this source's scoped chapters(a related but different table — Tränkbarkeitsklassen/treatability class —exists further in the book, outside the mined range); read DIN 68800-3directly before specifying a chemical treatment retention value.
Chemical wood protection (Präparieren): only after the constructional concept (§6.2) has done its best; use-class ↔ required retention/penetration per DIN 68800-3; framing for GK2+ in dry-climate DACH is often fully constructionally solvable (that is the point of the standard's hierarchy).
6.2 Constructional wood protection (Konstruktiver Holzschutz) — the rule set
Rot fungi need MC ≳ 20 % + oxygen + temperature; the design goal is not "dryness" but no persistent moisture — occasional wetting plus a guaranteed drying path. Decay of structural section is progressive and silent (at hidden beam heads) → these rules are structural rules:
- Keep structural timber out of the splash zone: ≥ 30 cm above finished
ground (plinth/sockel of massive material ≥ 300 mm; 40 cm is the safer trade rule — VERIFY with local practice), no timber-to-soil contact ever, no timber buried in masonry.
- Shed water fast: vertical faces stay drier than inclined; every
horizontal-ish timber face either slopes (≥ ~5°; flat end grain collects water) or is covered; rain-proof overhangs (deep eaves keep walls nearly dry); drip edges/Tropfkanten under every shelf; no water-holding concave geometries; open joints/shingles overlapped in the flow direction.
- Ventilate: back-ventilated cladding; beam heads in walls get an air
gap + DPC wrap (old-building rule for GK2); ridge/eave ventilation of roof cavities; no vapour-tight wrap on the cold side of a damp-prone member.
- Protect end grain (capillary suction climbs it): metal caps, sloped
cuts, side-board covers, wax/sealant on cut ends.
- Isolate from other materials: PE/bitumen strip under sills and posts
(also spreads bearing), no direct concrete contact, stainless/galvanized connectors compatible with the preservative.
- Design the moisture budget: diffusion-high-inside/low-outside (never
trap a damp layer between two near-closed skins), airtight layer protected, service leaks must be detectable/drainable.
- Maintenance zones declared at handover: exposed facade timber needs a
coating cycle (state it), horizontal members are the hardest detail on every building.
Section 7: Timber fire design (DIN EN 1995-1-2 + NA)
7.1 Why timber is a fire-friendly structure
Charring forms an insulating layer (≈ 0.65-0.8 mm/min) that protects the surviving core, while unprotected steel loses most strength by ~600 °C within minutes. Heavy timber reaches feuerhemmend/hochfeuerhemmend analogues (F30-F60; F60-BA/F90-BA with non-combustible linings per the DIN 4102-17 melting-point logic; MHolzBauRL for special buildings) by oversizing alone; planar CLT soffits + burn-off allowance reach F90 without a suspended ceiling.
7.2 Two verification methods
Method A — reduced characteristic lines: d_char,n = β_n·t_n; effective d_eff = d_char,n + k_0·d_0 (notional layer d_0 = 7 mm lost strength). k_0/d_0 branch CONFIRMED (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.166-167, Tab. 4.13): unprotected surfaces — k_0 = t/20 for t < 20 min, k_0 = 1.0 for t ≥ 20 min; protected surfaces — if the lining's char-onset time t_ch ≤ 20 min, k_0 = t/20 (t = t_ch); if t_ch > 20 min, k_0 interpolates linearly between 0 and 1 over 0 ≤ t ≤ t_ch.
β_n charring rate — CORRECTED table (Neuhaus p.141-142, Tab. 4.8, = EN 1995-1-2 Tab. 3.1), mm/min:
| Product | β_0 | β_n | |
|---|---|---|---|
| Softwood and beech, glulam, ρ_k ≥ 290 | 0.65 | 0.70 | |
| Softwood and beech, solid, ρ_k ≥ 290 | 0.65 | 0.80 (resolves "worked R30 used 0.8" — this is simply the correct standard value for solid softwood, not a conservative NA add-on) | |
| Hardwood except beech, ρ_k ≥ 290 | 0.65 | 0.70 | |
| Hardwood except beech, ρ_k ≥ 450 | 0.50 | 0.55 (linear interpolation 290<ρ_k<450 permitted) | |
| LVL, ρ_k ≥ 480 | 0.65 | 0.70 | |
| Wood cladding boards, ρ=450, 20mm | 0.90 | — | |
| Plywood, ρ=450, 20mm | 1.00 | — | |
| Other wood-based panels (OSB, particleboard, fibreboard), ρ=450, 20mm | 0.90 | — |
For other density/thickness board products: β_0,ρ,t = β_0·(450/ρ_k)·(20/h_p). Minimum width for the 1-D charring method: b_min = 2·d_char,0+80 (if d_char,0 ≥ 13mm) or 8.15·d_char,0 (below) — otherwise use β_n instead of β_0. Then run §4 checks on the reduced section with γ_M,fi = 1.0 and k_fi (§1.2).
Method B — reduced properties: gross section, k_fi (not γ_M,fi — see §1.2) = 1.25 on f_m,k (bending; compression/E factors per EN 1995-1-2 Tab. 2.1/NA — not independently re-verified this pass); k_mod,fi = 1 − (1/200)·(p/A). Buckling/LTB per EN 1995-1-1 §6.3 with fire-time restraint layout.
Protective linings (gypsum EN 520 type A/F/H) — CORRECTED, onset-time formula now given (Neuhaus p.151-152, Tab. 4.10): t_ch [min] = onset of charring under a protective layer. Wood cladding/board layers: t_ch = h_p/β_0. Single gypsum layer type A/F/H: t_ch = 2.8·h_p − 14 (taped joints, or open joints ≤ 2mm); t_ch = 2.8·h_p − 23 (open joints > 2mm). Two layers type A or H: t_ch = 2.8·h_p − 14, h_p = outer thickness + 50 % of inner. Two layers type F: same formula, h_p = outer + 80 % of inner (confirms the earlier 80 %/50 % split, now with the base equation). Mineral wool (≥20mm, ρ≥26 kg/m³, melting point ≥1000°C): t_ch = 0.07·(h_ins−20)·√ρ_ins (matches fire-protection-building §9.1's formula independently). Minimum fastener anchorage into unburnt wood l_a ≥ 10mm; required fastener length l_f,req = h_p + d_char,0 + l_a. Staggered joints. Cavity fire-stops in ventilated constructions per trade rules — see fire-protection-building.
Post-failure charring behaviour (genuinely new, Neuhaus p.148-150, Tab. 4.9) — optional depth beyond the load-bearing fixes above: between t_ch and lining failure t_f, type-F gypsum and mineral wool give a reduced rate via k₂ (gypsum type F: k₂=1−0.018·h_p [inner thickness]; mineral wool: k₂=1 at h_ins=20mm down to 0.6 at h_ins≥45mm, interpolate). After lining failure (t_f ≤ t ≤ t_a, char depth < 25mm) the rate doubles, k₃=2; once char depth reaches 25mm, k₃ returns to 1.
Connection fire resistance (genuinely new, Neuhaus p.194-196, Tab. 4.19, EN 1995-1-2 §6.2.2.1) — more precise than the flat k_fi table above for unprotected dowel-type fasteners in shear: F_v,Rk,fi = η·F_v,Rk·k_fi, η = e^(−k·t_d,fi), k by fastener type: nails/screws 0.08; bolts wood-wood 0.065; bolts steel-wood 0.085; dowels wood-wood 0.04 (best-surviving); dowels steel-wood 0.085 (worst-surviving). At t_d,fi = 30min, steel-side-plate dowel connections retain only ~9 % of ambient capacity, while wood-wood dowel connections retain ~35 % — materially changes which connection type to specify for a fire-rated timber joint: prefer wood-wood dowels over steel-side-plate dowels wherever a connection must survive a fire rating unprotected.
7.3 Worked example — R30 beam, four-sided exposed
C24 14/24, l = 5 m, e = 0.60 m tributary; g_k 1.5, q_k 2.0 kN/m²; fire combination γG = γQ = 1.0, ψ1 = 0.5 → q_fi = 1.5 kN/m → M_fi = 4.69 kNm.
- Method A: d_char,n = β_n·t = 0.8·30 = 24 mm; notional +7 → section
7.8/17.8 cm; W = 411.9 cm³ → σ = 11.39 N/mm²; f_m,fi = k_fi·f_m,k = 1.25·24 = 30 N/mm² (k_fi resolved above, not γ_M,fi); f_md,fi = k_mod,fi·f_m,fi/γ_M,fi = 1.0·30/1.0 = 30 → LTB: σ_crit = 0.78·b²/(h·l)·E_eff → 39.5; λ_rel = √(24/39.5) = 0.78 → k_crit = 1.56−0.75·0.78 = 0.975 → util 11.39/(0.975·30) = 0.39 ✓
- Method B: residual 9.2/19.2, W = 565 cm³, σ = 8.30;
k_mod,fi = 1−(1/200)(p/A) = 0.839 → f_d = 25.2; λ_rel = 0.69 < 0.75 → k_crit = 1 → util 0.33 ✓
7.4 Fire detailing rules that decide the outcome
- Connections: fastener steel chars faster than timber → shield the connection
zone or limit contribution; hold-downs/straps need their own protection.
- Linings must survive wall/floor movement (slotted fixings; no brittle board
joints over shrinkage-loaded stud lines).
- Ventilated cavities = chimney effect → fire-stops; non-combustible cavity
fill in concealed lines per class.
- Effective width of a charred member is measured between notional lines —
never "the core looks fine".
Section 8: Steel — material, sections, member checks
8.0 Elastic constants (all structural steel grades, EN 1993-1-1 §3.2.6 — for FEM)
E = 210,000 N/mm², G = 81,000 N/mm², ν (Poisson) = 0.3, α_T (thermal expansion) = 12·10⁻⁶/K, ρ = 7850 kg/m³ — grade-independent (S235 through S460 share the same elastic constants; only f_y/f_u change). Use these directly as the isotropic material definition for a steel member/plate FEM model; do not substitute a design f_yd for E — stiffness and strength are separate inputs.
8.1 Grades (EN 10025; nominal f_y for t ≤ 16 mm)
| Grade | f_y [N/mm²] | f_u [N/mm²] | ε = √(235/f_y) | Typical use | |
|---|---|---|---|---|---|
| S235 (JR/J2) | 235 | 360 | 1.00 | trusses, secondary, light frames | |
| S275 | 275 | 410 | 0.92 | — | |
| S355 (JR/J2/K1…) | 355 | 470 | 0.81 | portals, heavy frames, welded | |
| S420/S460 | 420/460 | 530/550 | 0.75/0.71 | special (thinner plates, buckling limits) |
f_y/f_u drop with nominal product thickness t (CONFIRMED against Wendehorst Tab. 11.4, N/mm², t ≤ 40 mm / 40 < t ≤ 80 mm — read EN 10025-2 direct for t > 80 mm or other delivery conditions):
| Grade (EN 10025-2) | f_y, t≤40 | f_u, t≤40 | f_y, 40<t≤80 | f_u, 40<t≤80 | |
|---|---|---|---|---|---|
| S235 | 235 | 360 | 215 | 360 | |
| S275 | 275 | 430 | 255 | 410 | |
| S355 | 355 | 490 | 335 | 470 | |
| S460 | 460 | 550 | 420 | 550 |
(EN 10025-3 normalized N/NL, -4 thermomech M/ML, -5 weathering W and -6 quenched Q/QL run a few N/mm² apart from the -2 values above at the same nominal grade — use the -2 table for ordinary hot-rolled sections, switch tables only if the mill certificate names a different product standard.) Ductility check (EN 10025, all grades to S460): f_u/f_y ≥ 1.10, elongation ≥ 15 %, uniform elongation ε_u ≥ 15·f_y/E — needed for plastic (Mpl) design to be valid; grades > S460 to S700 relax to 1.05 / 10 %.
⚠ VERIFY: delivery condition/impact-energy class (JR/J0/J2/K1-K2) is atoughness-and-weldability decision, not a strength one — winter sites andthick welded plates need J2/K. Weldability: carbon-equivalent limits ofEN 1090-2; preheat by thickness.
8.2 Profile families (EN 10365 designation)
| Family | Designation | Notes | |
|---|---|---|---|
| Parallel-flange I/H | IPE 300 (thin economic web), HEA/HEB/HEM 300 (HEB = heavier; M deepest), IPAA/IPAR? (uncommon) | workhorses: beams IPE, columns HE; h/b ≈ 1.5 (IPE) to 1.0 (HEM) | |
| Tapered-flange I/U | UPN 80-400, UPE 300 | legacy channels, UPE thicker; channel section: load plane off the shear/torsion centre induces St. Venant + warping torsion (worked UPE400 trench plank: rejected) | |
| Angle | L 50×50×5 … 200×200×20? | braces, gussets, battens; singly symmetric → torsional-flexural buckling check | |
| Hollow | CHS 168.3×6.3 etc., RHS/SHS per EN 10219/10210 | torsion-stiff, better fire/corrosion surface-per-mass than open thin sections; CHS = best for compression+torsion (crane, lattice) | |
| Plate/welded | t × b, welded girders S235/S355 | welded I: h/b > 2 → LTB curve c; plate girder stiffener layout → EN 1993-1-5 | |
| Cold-formed sheet | trapezoidal sheeting; Z/C purlins 150-250 × 1.5-2.5 mm galv | Z-purlins sleeved over frames; sag rods > ~6 m runs |
Excerpt of section properties as used in the worked examples of this file (digest values, unverified — READ producer/EN 10365 tables for anything real):
| Section | A cm² | Wel,y cm³ | Wpl,y cm³ | i_y cm | i_z cm | I_y cm⁴ | I_z cm⁴ | I_w cm⁶ | I_T cm⁴ | notes | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| IPE 270 | 45.9 | 429 | — | 11.2 | 3.02 | 5790 | 420 | 70 580 | 15.9 | tf 10.2; S355 example | |
| IPE 360 | — | — | 1019 | — | — | — | — | — | — | Vpl 476 kN; Mpl S235 239.5; IPE330 (189) fails the same check | |
| IPE 450 | 98.8 | 1500 | 1702 | 18.5 | 4.12 | 33740 | 1676 | 791 (×10³ cm⁶) | 66.9 | LTB example, S235; A and W_pl,y confirmed against Wendehorst's IPE profile table (row h=450) — the earlier "363.6" cell was a mis-extraction, real W_pl,y = 1702 cm³. Other columns are standard EN 10365 catalogue values, not individually re-parsed from the source digest this pass | |
| UPE 400 | 91.9 | — | — | — | — | 20 981 | — | — | I_s 82.2 | channel: y_T = 6.06 cm | |
| HE 240 B / HE 280 A | — | — | — | — | — | — | — | — | — | frame-column and two-span-beam examples (HE280A util 0.95 elastic; Mpl,Rd 261.3; A_v 31.8?) | |
| HE 300 B | — | — | — | — | — | — | — | — | — | S235: Mpl 439, Npl 3502 kN, Vpl 642 kN, b/h? 7.5/5? | |
| HE 340 A | — | 1680 | — | — | — | 27 690 | — | 1.824·10⁶ | 127 | canopy example | |
| HE 500 A | — | — | — | — | — | — | — | — | — | S235: Npl 4641, Vpl 1013, Mpl 927.8 | |
| HE 700 B | 344.4 | — | — | — | — | 290 200 | 33 685 | 7.01·10⁶ | 844 | crane girder example | |
| CHS 355.6×8 | — | 742 | — | — | — | 13 201 | — | 0 (closed) | — | the torsion-stiff answer | |
| RHS/box 500×… | — | — | — | — | — | — | — | — | — | (section factor for fire: A/V) |
⚠ VERIFY every row against DIN EN 10365 + producer tables (e.g. the IPE 450Wpl = 363.6 figure cannot be right for a 450-deep I — most likely a mis-extract;real Wpl,y ≈ 1702 cm³). These excerpt rows exist so the worked example chainsin §9-§10 can be followed, not as a section catalogue.
8.3 Cross-section classes (EN 1993-1-1 Table 5.2, ε = √(235/f_y))
| Element | Cl. 1 | Cl. 2 | Cl. 3 | Cl. 4 (slender) | |
|---|---|---|---|---|---|
| Flange outstand (compression) | c/t ≤ 9ε | ≤ 10ε | ≤ 14ε | > 14ε | |
| Web, bending | ≤ 72ε | ≤ 83ε (α?; ≤ 95ε? for α → real 83ε/95ε pair — VERIFY) | ≤ 124ε | > 124ε | |
| Web, uniform compression | ≤ 33ε | ≤ 38ε | ≤ 42ε | > 42ε | |
| Internal part, compression grad. ψ | per α = (1+ψ)/2 forms | — | — | — |
Class → which resistance formula applies: 1/2 plastic (Mpl), 3 elastic (Wel), 4 effective (EN 1993-1-5 ρ·b_eff; ρ = 0.776?/ρ = (λ̄_p − 0.055(3+ψ))/λ̄_p²? — use EC3 5.4 λ̄_p = √(f_y/σ_cr); σ_cr = k_σ·18.98·(t/b)²·? [kN/cm² form] with k_σ: 4.0 (uniform compression, both edges supported), 23.9 (pure bending, ψ=−1), 0.43 (outstand), 8.2−… (ψ gradient; a/b influence) — worked class-4 column: λ̄_p ≈ 1.03 → ρ ≈ 0.79; worked class-4 column in §8.3). Class-4 member: N_b,Rd = χ·A_eff·f_y/γ_M1 with λ̄ from gross-section N_cr (worked welded box example: A_eff 80.48 cm², χ 0.833 (curve c) → N_b,Rd 1432 kN).
8.4 Tension members
N_t,Rd (gross yield) = A·f_y/γ_M0net fracture: 0.9·A_net·f_u/γ_M2 ; angles/tees: shear-lag β (worked: β2 = 0.5for 2 bolts — EC3 3.10.3 formula; 1 bolt: 2(e_2−d_0/2)·t·f_u/γ_M2)staggered holes: zig-zag net section; bolt holes d_0 = d + 2 mm (normal)
Example: Ø24 S235 bar: N_pl,Rd = 106.3 kN (A·23.5); hybrid built-up: ΣA_i·f_yi.
8.5 Bending
M_c,Rd = W_pl·f_y/γ_M0 ≤ W_el·f_y/γ_M0·1.5 (class 1/2 plastic, capped)shear-reduced (V_Ed > 0.5·V_pl,Rd): ρ = (2V/V_pl)²−1;M_V,Rd = (W_pl − A_w²/(4t_w))·(1−ρ)·f_y/γ_M0 (A_w = h_w·t_w)N-M class 1/2: if n = N_Ed/N_pl,Rd > 0.25 →M_N,Rd = M_pl,Rd·(1−n)/(1−0.5a) ≤ M_pl,Rd, a = web area share (A−2·b·t_f)/A(worked a = 0.283/0.235/0.425 variants — VERIFY a-definition, EC3 6.2.9(3))
Worked: IPE360 V 287.5/476.3 = 0.604 → ρ 0.043 → M_V,Rd 237.2 vs 190 → util 0.80 ✓ (IPE330 fails); HE300B M-N chain MN,Rd 249.5 ✓; U-section asymmetric M-N region formulas per plastic-axis zone (tables) — VERIFY. Plastic vs elastic economy (worked two-span, q 50 kN/m, L 6 m, S235): elastic → HE280A util 0.95; mechanism design with hinge at a = 0.414·L → HE240A, 21 % lighter, needs class 1 + rotation capacity; redistribution ≤ 15 % for continuous beams (class 1/2).
8.6 Shear and web bearing
V_pl,Rd = A_v·(f_y/√3)/γ_M0; A_v = A − 2b·t_f + (t_w + 2r)·t_f ≥ h_w·t_w(worked HE280A: A_v 31.8? cm² → V_pl 431.5 kN)unstiffened transverse bearing (1993-1-5 §6 / 1-8 6.2.6):F_cr = k_F·π²E·t_w³/(12(1−ν²))·s̄²/h_w²; k_F = 6 + 2·s_s/h_w (stiff end:6; with intermediate stiffener 3.97→6 range)l_y = s_s + 2(t_f + r) + m_1 + m_2; m_i = 0.14·(b_f… )·(235/f_y) (31.4/17.9)λ̄_F = √(A_w·f_y/F_cr) ≤ 0.5 → χ_F = 1; else χ_F curve (0.72? class) →F_Rd = χ_F·l_y·t_w·f_y/γ_M1 (worked min-of-three 166 governs)alt 1993-1-8 form: b_eff = s_s + 2.5(t_f + r); ω = 1/√(1 + 3(b_eff/b_w)²·t_f/A_v-type term) = 0.903 (digest formula garbled — VERIFY 6.2.6.2);F_Rd = ω·β·b_eff·t_w·f_y/γ_M0 (183)bearing stiffeners: design as strut/panel; stiffen at every concentrated load> capacity — the classic unstiffened web failure under a beam reaction.
Section 9: Steel stability — buckling and lateral-torsional buckling
9.1 Flexural buckling of members (Biegeknicken)
L_cr = β·L (β from frame: pinned 1.0; fixed-free 2.0; fixed-pinned 0.7;two-hinged frame column β from alignment chart / eigenvalue — worked:β_cr = 2.32 from c = (I_c/h)/(I_r/L) = 0.974 via the alignment chart — VERIFY)N_cr = π²·E·I / L_cr²λ̄ = √(A·f_y/N_cr) = (L_cr/i)/(93.9·ε) (worked: S355 → /(76.4))Φ = 0.5·[1 + α·(λ̄ − 0.2) + 0.75·λ̄²]χ = 1/(Φ + √(Φ² − λ̄²)) ≤ 1.0N_b,Rd = χ·A·f_y/γ_M1 (class 4: A_eff)Buckling curve α: a 0.21 · b 0.34 · c 0.49 · d 0.76rolled I about y: b (h/b ≤ 1.2, t_f ≤ 40) / c; about z: c (t_f ≤ 40) / d?;welded: c/d depending flange edge prep — VERIFY EN 1993-1-1 Table 6.2;the examples used: HE160A strong-axis b; class-4 welded box c;lattice chords c (U-sections); IPE450 LTB about? c (h/b > 2, welded-analogue)
Worked (K-braced column HE160A S355, L_cr 8 m out-of-plane): λ̄ = 1.19 → curve b χ = 0.31 → N_b,Rd 388 kN > 375 ✓; TF mode λ̄_T 0.86 not governing. Torsional-flexural (singly symmetric / class 3-4 / angles, channels): c² = I_w/I_z + (E·I_w)/(G·I_z)·(L/π)²; N_cr,TF = π²EI_z/(c²L²)·1/(1−i_p²/i_M²) (worked: N_cr,TF 3263 ≪ 75175 → TF governs; λ̄ 1.023 → curve c about the rotation axis, χ 0.53, N_Rd = χ·A_eff·f_y/γ_M1, util 0.97). Battened/lattice struts: shear-deformable: S_v from batten/lacing flexibility; EI_eff with 1/(1+(π²EI/(S_v L²))); e₀ = a/5 between panel points; M = N·e₀/(1−N/N_cr); chord and lacing-bar checks separately (worked: global util 0.74, chord 0.92, lacing bar 0.33; battened frame-strut ≈ equivalent).
9.2 Frame second-order and bracing rules
Imperfection: θ = (1/200)·α_h·α_m; α_h = 2/√h (0.5-1.0); α_m = √(1+1/m);worked h = 5 m → θ = 1/258; bracing force H = θ·ΣV per storey.Method comparison (worked hall frame HE240B/IPE400, F_d 1200 kN): plumb forcealone → 1500 kN (+25 % too generous when L_cr long); scaled eigenmode /substitute member (Ersatzstab) → 1204-1205 kN ✓ — use substitute-member orGMNIA, not bare plumb. Second-order: M = M_I/(1 − N_Ed/N_cr) (worked195 = 150 + 45 kNm).Non-sway: 2nd-order effects ignorable if moment increase < 10 % (θ ≤ 0.1 formper EC3 5.2.1; the K1 = 0.31 check in the digest is the EC2 analogue —VERIFY the EC3 form). Bracing stiffness practice: ≥ 1.5-2 % of the maxchord force restrained (timber worked case: 1.11 + wind = 2.31 kN/m lineload). Sway SLS limit (worked): head displacement h/80 — VERIFY NA.
9.3 Lateral-torsional buckling (Biegedrillknicken) — full chain
M_cr = C_1·(π²E·I_z/L²)·√( I_w/I_z + (L/π)²·G·I_T/(E·I_z) ) (C_1 frommoment shape & load height; worked parabola C_1 = 1.13; Iw/IT from tables)λ̄_LT = √(W_pl·f_y/M_cr) (class 1/2) = √(W_el·f_y/M_cr) (class 3)curve (rolled, h/b ≤ 2: b α 0.34; welded/h/b > 2: c α 0.49 — worked IPE450 c);Φ_LT = 0.5[1 + α_LT(λ̄ − 0.2) + 0.75λ̄²]; χ_LT ≤ 1.0modifier (uniform-moment basis → actual diagram): k_c from moment ratio ψ(ψ = 0 reverse curvature: k_c up to 1.33; ψ = 1: 1.0; parabolic 0.94);f from the modifier formula (worked f = 0.974 — VERIFY form); χ_LT,mod = χ_LT/f(alternative: compression-flange method if,z, λ̄_f — worked showed it canFAIL where full LTB passes; use full method + kc)M_b,Rd = χ_LT,mod·W_pl·f_y/γ_M1 ≤ M_pl,Rd? (≤1.0·)
Worked LTB (IPE450 S235, L = 6 m, fork ends, unrestrained, parabolic M, M_Ed = 177.5 kNm): M_cr = 350.9 kNm → λ̄ = 1.07 → χ_LT 0.596 (curve c) → k_c 0.94 → χ_LT,mod = 0.612 → M_b,Rd = 0.612·W_pl,y·23.5/100. With the confirmed W_pl,y = 1702 cm³ (§8.2) this gives M_b,Rd ≈ 245 kNm → util 177.5/245 ≈ 0.72 — recompute this chain with 1702 (not the earlier "363.6" mis-extraction) before quoting the utilization. Coped beam rule (worked): cope with h_a/h ≥ 0.7 and a/h ≈ 0.5 → reduce M_cr by V ≈ 0.68 (interaction chart) and downgrade the buckling curve one letter; capacity drop ≈ 30 % → prefer a bolted web-cleat or a smaller cope. Restrained axis (worked hall column IPE270 on rotational spring from sheeting): torsional-flexural about the rotation axis D: I_w,D = I_w + I_z· z_D²; half-wave number m from (L/π)(c_θ/EI_w,D)^¼ → N_cr,TF; M_cr with I_T,id = I_T + c_θ·L⁴/(π⁴·G)?? (worked 47.56 cm⁴) and k-chart → util TF-check 1.08 → FAIL — conclusion in the source: increase section or improve the rotational restraint (self-tapping density/screw class), don't just thicken the web. Torsion (warping, thin-open sections): B (bimoment) + T_t (St. Venant) superposition; κ = (G·I_T/E·I_w)^0.25; fork support: ϑ = 0, B = 0; σ = M_y/W + 0.75·B·ω/I_w + 0.75·σ_local (25 % local reduction allowed when superposed); a CHS of the same mass is torsionally ~5-20× stiffer — for eccentrically loaded canopy edges, choose closed sections (worked: I-defl 69.8 cm vs CHS 5.1 cm).
9.4 Web plate buckling (Plattenbeulen, EN 1993-1-5) & warping torsion
(Wölbkrafttorsion)
When it governs: welded plate girders (Vollwandträger) and class-4 welded I-sections — the web is almost always slender (c/t > 124ε in bending; under shear the limit drops to ≈ 48.6·ε/√(τ_Ed/(f_y/√3)) — digest form garbled, VERIFY), so the web is post-buckling: elastic, no plastic reserve, γ_M1 = 1.1, via effective widths (ρ·c) or the reduced-stress method.
Buckling-stress and reduction chain (numbers as worked, S235): σ_cr = k_σ·18.98·(t/c)² [kN/cm²] (VERIFY constant form); λ̄_p = √(f_y/σ_cr); ρ = (λ̄_p − 0.055·(3+ψ))/λ̄_p² ≤ 1.0 (digest shows two branches — (λ̄_p−0.188)/λ̄_p² and (λ̄_p−0.055)/λ̄_p² — VERIFY); b_eff = ρ·c split b_c1 = 0.4·b_eff at the compression edge / b_c2 = rest. k_σ: 0.43 outstand (one edge free), 4.0 uniform compression, 23.9 pure bending (ψ = −1), 8.2 − 1.05ψ gradient (worked ψ = 0.2 prints 6.56 — the arithmetic does not close, VERIFY); shear: k_τ = 5.34 + 4/(a/b)² (sub-field a/b = 2.02 → 6.32 ✓), whole panel with intermediate stiffener 3.4 + stiffener-rigidity term (garbled VERIFY).
Class-4 welded I-column (worked: 8 m, L_cr = 0.7·L, flanges 400×20, web 360×6 — VERIFY web size): flange outstand c/t 19.28 > 14ε and web
42ε → class 4 both; flange k_σ 0.43 → σ_cr 21.96 → λ̄_p 1.035 → ρ 0.791
→ A_eff,f 31.94 cm²; web k_σ 4 → σ_cr 22.12 → ρ 0.763 → A_eff,w 16.60 cm²; ΣA_eff = 80.48 cm²; λ̄ from GROSS-section N_cr 7050 kN → 0.518 → curve c χ 0.833 → N_b,Rd = χ·A_eff·f_y/γ_M1 = 1432 kN (class-4 rule: A_eff in resistance, gross I in slenderness).
Plate girder with longitudinal stiffener (worked: S355, web 1000×8 → c/t 123.6, M_Ed 2240 kNm, V_Ed 640 kN, σ_x,Ed 29.23 / τ_Ed 7.84 kN/cm²):
- Stiffener layout from reduced-stress charts: unstiffened web allowed
within ≈ 2.0 m of the supports (chart coordinate x ≈ 0.39·? — cell lost, VERIFY); design section at 0.5·b from the edge (VERIFY); longitudinal stiffener (L80×40×6, single-side — VERIFY) at the upper 4/10 of web depth near the highly stressed flange.
- Field 3 — bending zone (ψ = −1, k_σ 23.9): σ_cr 29.70 → λ̄_p 1.093
→ ρ 0.823 → b_eff 40.69 (16.27 + 24.42) → ΔA 7.0 cm² → A_eff 193 cm², W_y,eff 7027 cm³ → η₁ = 31.88/35.5 = 0.898 ✓ (example used γ 1.0 — §1.2 flag).
- **Field 1 — σ + τ combined, reduced-stress method (deformable bearing
stiffener): σ_v,Ed = √(σ² + 3τ²) = 18.50; f_a,ult,k/σ_v,Ed = 35.5/18.5 = 1.92; ā_x = σ_cr,x/σ_x,Ed = 2.35, ā_τ = 1.00 → combined ā_cr = 0.92 (combination form garbled VERIFY); λ̄_p = √(1.92/0.92) = 1.445 → χ_w = 0.83/λ̄_p = 0.574; check σ_v,Ed ≤ χ_w·f_y/γ_M1 → util 0.999 — governs, the girder is just adequate**.
- Field 2 — longitudinally stiffened (effective widths): sub-fields
ψ 0.2 (ρ 0.945) and ψ −0.5 (ρ 1.0 — no reduction); stiffener + plate group σ_cr,sl 70.48 kN/cm² → plate-vs-global interaction ξ (printed sqrt goes negative; digest took 0.064 — VERIFY formula); ρ_c 0.933 → W_y,eff 7237 cm³ → η₁ 0.749 ✓.
- Shear resistance V_b,Rd: panel λ̄_w = 1.25 (whole field governs over
sub-fields) → χ_w 0.664 → V_bw,Rd 979 kN; flange contribution V_bf,Rd ≈ 20 kN (from M_f,Rd 2173 vs M_Ed 1924) → V_b,Rd ≈ 947 kN → η₃ 0.676 ✓; no extra M–V interaction once the flange-moment effect is included.
- Stiffener torsional (drill) buckling: I_T = Σb·t³/3 = 0.82 cm⁴; the
criterion prints garbled but the worked conclusion is check mandatory for single-side stiffeners — VERIFY against EN 1993-1-5.
Warping torsion of open thin-walled sections (extends the §9.3 torsion paragraph):
- T = T_t (St. Venant) + T_w = −B′ (bimoment); warping slenderness
κ = (G·I_T/E·I_w)^¼ (digest prints a square root — VERIFY root order; worked κ 7.50 / 5.18 1/m); restraint offset axis: I_D = I_w + I_z·z_D² (worked 505·10³ cm⁶? — suspect cell VERIFY); bimoment under distributed twist m: B ≈ (m/(2κ))·tanh-type form (Gl. 11.39 — VERIFY).
- σ_x = M_y/W_y + 0.75·B·ω/I_w + 0.75·σ_0,local (worked 10.97 + 3.77 +
4.53 = 19.27 < 23.5 ✓; the 25 % local-wheel-load reduction applies only in superposition); τ = T_t-form/I_T·t + T_w·S_ω/(I_w·t) (St. Venant term printed "1.65·?/I_T" — VERIFY; worked τ_total 11.62 < f_y/√3 = 13.57 ✓).
- Boundary conditions: fork support (Gabel) = ϑ = 0, B = 0 — **VERIFY
pairing per support type**; multi-span / crane girders by the initial-parameter 6×6 matrix per segment (worked HE700B: eccentric lateral load T_A = H·z_M with z_M ≈ 14.3 cm; B_Ed,max ≈ 178.4·10³ kNcm²; σ_x,Ed −21.63 kN/cm² governs).
- First-order waiver (rule of thumb): M_cr/M_Ed ≥ 10 → Th. I sufficient
(VERIFY form); for torsion-governed edges choose closed sections — thickening the web never fixes warping flexibility.
Section 10: Steel connections (EN 1993-1-8)
10.1 Bolts
| Item | Value / rule | |
|---|---|---|
| Property classes | 4.6/4.8 (ordinary), 5.6/5.8/6.8, 8.8/10.9 (preloaded HRSG per EN 14399, "HV"), proof stress f_ub 400/420/500/600/640/800/1040? MPa (worked: 8.8 f_ub = 800, 10.9 = 1000) | |
| Stress area | M16 A_s 157 mm²; M20 245 mm² (worked: M20 11.9 HRSG A_s 2.45 cm² — A_s,nom 3.03? VERIFY tensile vs nominal shear area, threaded vs unthreaded position) | |
| Shear (bearing-type SL) | F_v,Rd = α_v·f_ub·A/γ_M2. α_v is set by WHICH cross-section sits in the shear plane, not by grade tier alone (CONFIRMED against Wendehorst Tab. 11.175 = EN 1993-1-8 Table 3.4): shank in shear plane → α_v = 0.6 for every grade 4.6/5.6/8.8/10.9 (A = shank area); thread in shear plane → α_v = 0.6 for 4.6/5.6/8.8, α_v = 0.5 only for 10.9 (A = A_s, stress area). The worked 60.3 kN @M16 8.8 with α_v 0.6 is correct (thread-in-plane, 8.8 keeps 0.6). | |
| Tension | F_t,Rd = k_2·f_ub·A_s/γ_M2, k_2 = 0.9 (0.63 for countersunk). F_t,Rd table (kN, CONFIRMED against Wendehorst Tab. 11.178): M12/M16/M20/M22/M24/M27/M30/M36 — grade 4.6: 24.3/45.2/70.6/87.3/101.7/132.2/161.6/235.3; grade 8.8: 48.6/90.4/141.1/174.5/203.3/264.4/323.1/470.6; grade 10.9: 60.7/113.0/176.4/218.2/254.2/330.5/403.9/588.2 | |
| Bearing | F_b,Rd = [min(2.8·e_1/d_0; 1.4·p_1/d_0; α_b)] · [min(2.8·e_2/d_0−1.7; 1.4·p_2/d_0−1.7; 2.5)] · d·t·f_u/γ_M2, α_b = min(f_u,b/f_u; 1.0) | |
| Eccentric group | component method: resolve F_x/F_z; vector check √((F_E,x/F_Rd,x)² + (F_E,z/F_Rd,z)²) ≤ 1; or polar I_p method for torsion (worked double-angle: F_v,i = F·(1/n ± e·z/I_p)) | |
| Spacing | min: e_1,e_2 = 1.2·d_0; p_1 = 2.2·d_0 (end, static; 1.6·d_0?); p_2 = 2.4·d_0; max: e_1,e_2 ≤ 4t+40 (≤ 200 mm?); p ≤ 14t (≤ 200 mm compression; VERIFY) | |
| Combined V+T | (F_v/F_v,Rd)² + (1.4·F_t/F_t,Rd)² ≤ 1.0 (worked 1.05 → "marginal, acceptable because plate mode governs" — do not copy this leniency; VERIFY per EN 1993-1-8 6.3.2.3) | |
| Preloaded HRSG | slip resistance µ·F_{p,C}/γ_M3 (slip classes A/B/C/D by surface); pretension 0.7·f_ub·A_s (verified torque/slip-indicating); GV = true force-fit, replaces site welding, stiff; no painted surface in a slip-critical class unless tested | |
| Block shear | F = f_u·A_nt/γ_M2 + f_y·A_nv/(√3·γ_M0) (worked end-plate 278 kN) | |
| T-stub (end plate/cleat) | mode 1: F_T,1 = 4·M_pl/m per leff; mode 2: F_T,2 = (2M_pl + ΣF_t,Rd?·n)/(…) (worked form (2Mpl+5nFt)/(4m+5)); mode 3: bolt failure ΣF_t,Rd (2 per bolt row?) ; M_pl = 0.25·l_eff·t²·f_y/γ_M0; leff min circular/linear patterns (worked: FT,2 governs 667 kN); prying Q included; anchor-row analogue → concrete-detailing |
10.2 Welds
| Item | Value / rule | |
|---|---|---|
| Directional method | σ_v = √(σ_⊥² + 3·(τ_⊥² + τ_∥²)) ≤ f_u/(β_w·γ_M2); σ_⊥ compressive normal to throat needs no check (6.2.3?; worked also quotes a τ ≤ 0.9·f_u/γ_M2? side check — VERIFY exact clause pair) | |
| β_w | 0.80 (S235) / 0.90 (S355) / 1.00 (S420) / 1.10 (S460) | |
| Simplified | F_w,Rd = a·l_eff·f_v,w,d with f_v,w,d = f_u/(√3·β_w·γ_M2); a_min = 3 mm (and ≥ (t_max−4)/2?); a_max by 1993-1-8 4.7 (worked derived a ≥ 5 mm from τ demand) | |
| Full-penetration butt | parent-metal governed (no separate check if executed to quality) | |
| Quality | NDTR (non-destructive testing rules) per EN ISO 5817 level B/C/D; shop-weld/site-bolt doctrine; field welding on site = last resort: no procedure control, no NDT, coating damage → redesign the detail |
10.3 Standard connection anatomy (portal + skeleton)
| Connection | Detail (worked values) | |
|---|---|---|
| Eaves (rafter-to-column) | extended end plate through haunch, 20-25 mm, 8-12× M20/M24 8.8, tension bolts in top rows; check: bolts, plate bending (T-stub), column-flange deformation (stiffeners at flange lines), web panel shear, compression zone | |
| Apex | end-plate splice 4-8× M20/M24; site splice located for crane + transport length | |
| Base | plate 20-30 mm, 4× HD M20-M24, embedment ~375-450 mm + anchor plate/washer, grout 25-40 mm; shear key (Schubknagge) under the plate so anchors carry only uplift; nominally-pinned design, but a real 4-bolt base has 10-20 % fixity — the engineer states which assumption is used for strength vs deflection | |
| Beam-to-column (pinned) | fin plate / double web angle, SL bolts (worked M16 4.6 double-angle: slip at column governs 171 kN); contact pressure on column flange check F_k = b_D·h_D·f_yd, h_D ≈ 3 cm (worked rule) | |
| Purlin/rail cleats | 2× M12/M16; setting the roof plane — model it | |
| Fly brace | angle purlin/side-rail → inner compression flange, bolted both ends — never omit | |
| Splices | column splice above floor line near inflection point; beam splice where M small; machined bearing faces + shell plates against slip (compression splices), bolts for handling only |
Section 11: Verification summary — the sigma/fd ≤ 1 table
| Check | Verification | Governing subtlety | |
|---|---|---|---|
| Timber tension | σ_t,0,d ≤ f_t,0,d | net section at fastener line; k_h small-section increase | |
| Timber compression | σ_c,0,d ≤ k_c·f_c,0,d | weak axis; restraints define L_cr | |
| Timber bending | σ_m,d ≤ k_crit·f_m,d | LTB (k_crit) often governs before strength | |
| Timber shear | τ_d ≤ f_v,d | cracked width k_cr·b at interior supports | |
| Timber bearing ⊥ | σ_c,90,d ≤ k_c,90·f_c,90,d | spreading (3+l+3)·b; edge distance | |
| Timber combined N+M | (σc/σc,crit)² + σm/(fm(1−σc/σc,crit)) ≤ 1 | both axes; substitute-column form | |
| Timber deflection / vibration | w_fin ≤ limit; w1 ≤ a(n) | k_def, ψ2, camber; NA tables | |
| Fastener group | F_v,Ed ≤ k_mod·n_ef·F_v,Rk/γ_M | spacing → n_ef → embedment depth | |
| Glued-in rod | bond + steel + splitting | every parameter is ETA-bound | |
| Steel tension | N ≤ min(N_pl,Rd; 0.9A_net·fu/γM2) | shear-lag, holes d+2 | |
| Steel bending | M ≤ χ_LT,mod·Wpl·fy/γM1; M ≤ Mpl; class | restraint = LTB length | |
| Steel shear | V ≤ Av·fy/(√3γM0) | 0.5 Vpl → reduce M | |
| Steel buckling | N ≤ χ·A·fy/γM1 | curve assignment + class 4 A_eff | |
| Steel combined | MN (n>0.25) + interaction kyy/kzy | TF mode for singly symmetric | |
| Web bearing | F ≤ χ_F·l_y·t_w·f_y/γM1 | unstiffened = local first failure | |
| Bolts | Fv/Fb/VT/block/T-stub per mode | group eccentricity; preload class | |
| Welds | σ_v ≤ fu/(βwγM2) | throat size + quality level | |
| Fire timber | M_fi ≤ χ_mod·W_reduced·f_fi | β_n, notional 7 mm, linings | |
| Fire steel | E_d,fi/R_d,fi,t ≤ 1 | A/V → θ_a,cr via μ0; protection |
Section 12: Steel durability — corrosion protection
| ISO 12944 class | Environment | Typical building case | |
|---|---|---|---|
| C1-C2 | dry heated interior / low humidity | office interiors (paint only) | |
| C3 | urban/atmospheric + moderate humidity | unheated halls, pool buildings (aggressive atmosphere, C3-C4) | |
| C4 | industrial + coastal moderate | parking decks, moderate coastal exposure | |
| C5-I/C5-M | industrial heavy / coastal-marine high | hall near sea, chemical zones | |
| CX/Im2 | immersion | water-contact elements (special systems) |
Strategy hierarchy (physics of a steel section): danger scales with surface per volume — fine open sections (thin L, slender trusses) corrode structurally fastest; closed hollows are the best shape; every water-holding orientation, capillary gap and crevice is a trap → hollows drainable and ventilable or fully sealed (welded end closures), no downward-facing open tubes, no moisture pockets at splices.
- Hot-dip galvanizing (EN ISO 1461): sacrificial + barrier; layer thickness
scales with section thickness (thin sections thinner layers — design for it); duplex (galv + paint) extends interval; cut edges/drilled holes need zinc-rich repair.
- Bimetallic rule: fasteners nobler than (or isolated from) the base —
steel against Zn/Al/Cr sacrificial-safe, against Cu bad. Weathering steel: stable layer only with true wet/dry cycles + drainage; runoff stains.
- Maintenance: coatings have renewal cycles; design access or accept a
lifecycle line item; inspect bolt heads and bearing zones (damage indicator tables: loose/missing bolts, torn plates, streak rust).
Section 13: Steel fire design (DIN EN 1993-1-2)
member: E_d,fi / R_d,fi,t ≤ 1.0material: k_y,θ = f_y,θ/f_y = 1.0 up to θ_a ≈ 350 °C then falling (≈50 % at~600 °C); NA floor: below ~350 °C no reduction (EU.2.3).heating: unprotected steel rate ∝ (k_w·A/V)/(c_a·ρ_a) — Profilfaktor A/V:open thin I ≈ 150-250 m⁻¹ (fastest), HE ≈ 80-150, filled CHS slowest.critical temperature: θ_a,cr from utilization μ0 = N_fi,Ed/N_pl,Rd(nomograph/table: μ0 ≈ 0.5 → ~600 °C, μ0 ≈ 1 → ~470-500 °C — VERIFY theNA table); low utilization is itself fire protection.protection menu: concrete encasement / composite column; slab-supported beams(slab = heat sink); fire boards (dry zones); intumescent paint (system +inspection); water-filled hollows; stocky sections (A/V as design input).tension: θ_a,lim only if elongation harms the structure; compression/flexure:full θ-dependent χ check.
GKL requirement mapping (Germany): GKL4 load-bearing timber = F60-BA (lining concept), GKL5 = F90-AB → a steel house/facade structure at GK4+ needs a protection package from day one; unprotected steel frames are realistically ≤ F30 at best for stocky sections — state this at system choice.
Section 14: The systems in practice
14.1 Timber practice lines
- Stud/panel (T1): DACH panel grids run on the 62.5 cm module to suit
joist/panel formats; platform storey-high; shear design = nail/screw line spacing of the sheathing (edge spacing IS the capacity); chord forces at panel ends → hold-downs into a designed anchor group; double top plate/sill continuity = the ring that ties the box; noggings/blocking scheduled at every wall-hung load before boards go on.
- Solid/CLT (T2): wall-floor nodes must keep the gravity path **along
grain into grain (steel angle/z-cleat on wall, ledge/trimmer, concrete dowel or WCC edge beam at higher storeys); perpendicular-bearing floors cap the stack at ~4-5 storeys (settlement) — above that switch node type. Insulation outside the static section (thickness ≠ U-value); airtightness via the few panel joints; acoustics need mass-spring (floating screed, loose-bound chippings/concrete topping). CLT high-rise:** end-grain stacked walls + steel inserts at columns (Brock Commons-type detail: CLT on steel telescopic tube columns with plywood diaphragm strips across the butt joints) — tall-timber is a connection + core + acoustics + fire-duration exercise, not a span exercise.
- Glulam halls (T3/T4): portal corners have no perpendicular-compression
path → mitre + diagonal block or factory-curved finger-jointed corner; 3-hinged apex pin splits transport to halves ≤ ~4 m; fork feet around columns; roof diaphragm ring (perimeter diagonals) + end-bay vertical bracing (mid-bay variant releases thermal movement).
- Trusses/binders (T4): depth ≈ L/6-L/12; pitch 15-45°; load at nodes only
(purlins must land on joints or add struts); tie at eaves unless the support takes thrust; collar in upper third; connectors: gussets, plate rings §5.7.
- WCC floors (T6): pin count = interface shear / pin capacity; transverse
tie steel in the slab over supports; connector reversal at cantilevers is the weak point — detail symmetric or avoid.
14.2 Steel practice lines
- Portal: bays 4.5-7.5 (6.0 typical) m; rafter depth L/40-55; haunch
depth 1.5-2× rafter, length L/10-L/7 — the haunch eats eaves headroom, model it before placing doors/windows; fly braces inside flange at eaves + first purlins; purlins Z 150-200 × 1.5-2.5 galv @ 1.2-1.8 m sleeved, sag rods > ~6 m; roof + wall cross-bracing in end bays and at ≤ ~5-bay intervals; base thrust H ≈ w·L²/(8f) three-hinged hand check:
| pitch | H per base @ L=12 m, w=9 kN/m | |
|---|---|---|
| 6° | ≈ 257 kN | |
| 10° | ≈ 153 | |
| 15° | ≈ 101 | |
| 20° | ≈ 74 |
→ pitch 15-25° is free structural performance; resolve thrust into a tie rod/beam under the slab (protected, on the services drawing so nobody trenches it), moment pads, or a stiff ground ring — never the unreinforced slab.
- Trusses: 10 m → >100 m; welded or bolted plate nodes; crown/ridge
splice at the site transport limit; camber preset for deflection and drainage; chord restraint = the purlin/brace line — design the sheeting-to-purlin screw group for the chord-force fraction; lattice girders double as floor diaphragm substitutes.
- Multi-storey skeleton: pinned beam→column default (fin plate); moment
where drift demands; braced by cores + K/X bracing (tension-only X needs both diagonals; single tension diagonal cannot reverse); column splices above floor at the inflection point; base plates as §10.3; composite slab: head studs φ19 P_cRd concrete-governed (worked 61.4 kN) → n = V_L = N_pl,a/P_cRd, equidistant if M_pl,comp/M_pl,a ≤ ~2; b_eff per EC4 (worked: outer field 3.40 m of 5.0 m bay; inner 2.80; support 2.0); longitudinal shear: tie reinforcement in flange v_Ed·cot β/h·f_sd; camber for dead-load deflection (worked 2.8 cm); slim-floor shelf beams where services must run flat.
- Hybrids: steel beam inside masonry/RC → isolate (soft joint), corrosion
protection at the pocket, bearing plate; timber floor on steel = perpendicular compression solved with a saddle or top-flange plate + elastomer; transfer girder logic at platform interfaces (concrete).
14.3 Anti-pattern quick list (both materials)
| Anti-pattern | Consequence | |
|---|---|---|
| fly-brace / flange restraint omitted | LTB collapse of the "complete-looking" frame | |
| no longitudinal bracing on a portal building | mechanism in the long direction | |
| base thrust left to the floor slab | frame spreads, slab cracks, ridge sags | |
| hold-down missing at shear-panel end | panel overturns; bracing does nothing | |
| nails relied on for uplift/withdrawal | roof leaves in the first storm | |
| field welding thin sections / field punch-outs | destroyed capacity + coating | |
| timber in splash zone / buried end grain / beam head in damp masonry | GK exceeded → silent decay at the bearing | |
| bolt group checked for one load direction only | angled loads need the component check | |
| slip-critical joint built with ordinary bearing bolts | slip, deflections, fatigue | |
| unstiffened web under a beam reaction | local web crippling (first failure) | |
| unprotected slender steel promised F90 | not credible — change section or protection | |
| cross-grain shrinkage put into a bearing/stack line | gaps, loosened bolts, sagging roof | |
| masonry infill built tight into a frame, unanalysed | short-column/stiffness trap | |
| supplier calculation accepted as the engineering | nobody checked foundation, thrust, uplift |
Section 15: FreeCAD modelling + IFC
Pair with the FreeCAD-BIM skill for the Site/Building/Storey hierarchy, parametric openings and FEM handoff.
15.1 Defaults
| Item | Default | IFC class / note | |
|---|---|---|---|
| Steel beam/column | Arch Structure with profile from the profile library — name it by the EN 10365 designation (IPE 300, HEB 240, HSS 200x100x8) | IfcBeam / IfcColumn; profile name + grade (S235/S355) in the type description; Pset Pset_BeamCommon/Pset_ColumnCommon | |
| Haunch, base plate, fin plate | model explicitly as small solids/plates | IfcMechanicalFastener / IfcPlate; never "implied" | |
| Bracing/struts/purlins | IfcMember, model the braced bays at least | if invisible in the model, invisible on site | |
| Tie rod / sag rods | model them — the item most often value-engineered out | IfcMember | |
| Glulam/timber member | rectangular Part b×h at nominal size (EN 336); camber as swept profile only if the file carries it | IfcBeam/IfcColumn/IfcMember; material class ("GL28h" / "C24") + service class + DIN 68800 GK class in properties | |
| Stud wall | model as Arch Wall, overall 140-240 mm + finish; do not model every stud whole-house — one representative bay only | IfcWall (LoadBearing = True), framing depth in metadata | |
| CLT panel | IfcSlab/IfcWall with layer set (plies + top/bottom), span direction marked | store lay-up 3s 20/40/20 in properties | |
| Shear-panel fastener lines | represent as notes/types, not individual nails | IfcMechanicalFastener type rows where a count matters | |
| Hold-down / anchor | small explicit object at panel ends + anchor position schedule | IfcMechanicalFastener | |
| Foundation | model it — timber/steel concentrate uplift + thrust + point loads | IfcFooting | |
| Storey heights | timber: 2.80/3.00 m; CLT grid from panel format; steel halls: eaves height incl. haunch check | ||
| Tolerances | +10 mm interface gaps at material boundaries (steel vs concrete accuracy classes differ); slotted holes modelled where movement is designed | DIN 18202 classes |
15.2 Modelling discipline
- **The lateral system, the haunch, the tie rod and the plinth are modelled
or they do not exist.** These are the four value-engineering casualties.
- Annotate the model README with: system, code basis (EC5/EC3 + NA edition),
assumed wind/snow/use loads, restraint layout (LTB lengths you assumed), section list with grades, fastener types with approval source, and the sentence "preliminary sizing — requires design and signature by a qualified structural engineer".
- FEM caveat: a solved member stress verifies none of: a bolt group, a T-stub
mode, a dowel yield pattern, n_ef group reduction, an unstiffened web, an LTB mode or a connection's perpendicular-tension path. Report that when exporting results.
- Export IFC4 (Reference View or Design Transfer); check the profile strings
survive (ifcopenshell), the storey aggregation is clean and the LoadBearing flags are set — fabricators cut quantities from these.
- Cutting lists / bar schedules may be produced from the model **as
planning aids only**, marked preliminary, never as shop drawings.
Section 16: Known gaps — state these when relevant
- **§3.1/3.2 solid timber tables, §3.4 k_mod, §4.5 k_c,90, §8.1 steel grade
thickness table, §8.2 IPE 450 row and §10.1 bolt α_v/F_t,Rd were cross-checked against Wendehorst Bautechnische Zahlentafeln (37th ed.) and corrected/confirmed in place** (2026 pass) — the E_0,05/E_0,mean columns were NOT transposed after all; the real errors were a few individual cells (C24 f_v,k, C35 f_c,90,k, the CL2 k_mod column, the hardwood k_c,90 default, the IPE450 Wpl,y mis-extraction, and the bolt α_v grade-vs-shear-plane rule). The rest of the §8.2 property excerpt (all rows except IPE 450) is chain-illustration, not a verified catalogue.
- **Timber Sections 3-7 received a second, deep cross-check against Neuhaus,
Ingenieurholzbau, 4th ed. 2017 (2026 pass) — this resolved the large majority of the timber VERIFY flags that survived pass 1: k_h/k_ℓ/k_cr size and cracked-width formulas (§3.4), the full k_def panel table (§3.4), BSH size/length limits (§3.7), M_y,Rk exponent and γ_M basis for dowel connections (§5.1), the a₁-a₄ spacing tables incl. a separate bolt/ threaded-rod table (§5.2), the n_ef formula incl. the α=90° special case (§5.3), nail withdrawal (now density-quadratic, not a diameter grid) and penetration reduction (§5.4), screw withdrawal formula and spacing (§5.5), the glued-in-rod bond-strength formula (now NA-normed, not purely ETA- bound, §5.5), the washer table (§5.6), the ring/shear-plate connector diameters/capacities/factors/n_eff formula — the single largest VERIFY block in the file (§5.7/5.7a), buckling k_c's β_c factor and l_ef table (§4.2), LTB k_crit thresholds and the glulam 1.4 stiffness factor (§4.3), shear k_cr by product (§4.4), the deflection-limit table and the vibration check method (§4.8), the notch k_v/F_t,90 formulas (§4.9), fire β_n/k_0/gypsum-onset-time/connection-fire-resistance (§7.2), and the γ_M,fi-vs-k_fi relabelling (§1.2). New subsections added: glued connections/finger joints and frame corners (§3.7), a holes-through-beams ruleset (§4.10), traditional carpentry joints (§5.10), and an EC5-specific fly-brace force formula (§4.3). Still open, not resolved by either pass:** plate-buckling k_σ/ρ formula branches (§9.4), warping-torsion κ root order, T-stub mode-2 formula (steel, unaffected by the timber source), the LTB effective-length l_ef exact algebraic form (§4.3 — table of a1/a2 coefficients is solid, the equation structure is not), the "45°→1.77" n_ef interpolation worked number (§5.3), diagonal-nailing NA reduction percentage (§5.4), staggered-hole net-section rule (§4.1), and the DIN 68800-3 preservative-class/hazard-level table (§6.1).
- No seismic (EN 1998) content; connection ductility for dissipative systems
is a specialist check. Nothing here is a fabrication drawing, cutting list or connection design; NA/revision state must be re-verified per project.
Section 17: Cross-references
| Need | Skill | |
|---|---|---|
| system choice, loads, massing of the building | structural-systems | |
| product classes, densities, CE/DoP, section standards | building-materials | |
| GK classes, required fire durations, escape | fire-protection-building | |
| anchors into concrete, base-plate grout, WCC topping | concrete-detailing | |
| uplift/bracing forces from wind & seismic | seismic-design / a loads skill | |
| footing under columns/hold-downs | geotechnics-foundations | |
| layer build-up, joints, water-shedding of timber/steel envelopes | construction-detailing | |
| modelling workflow, IFC QA, FEM pipeline | construction-freecad-bim | |
| framing-system alternatives catalogue (which system, spans, costs) | timber-steel-design |
Appendix S: Source Check 2026-10 — values re-read from the literature
Each line below was read again in the source books (sources/) in October 2026, with the place it stands at. "Confirmed" means: a dated book prints the rule and names the standard or law; it does not mean the current edition of that standard was opened. State law (LBO) and local rules still override; VERIFY tags elsewhere in this skill stay in force unless a line here names the edition. Where a line here differs from a section of this skill, that section was corrected and names the line ("S.n"); the appendix governs.
S.1 Purlin roof of a house — spacings
- Typical: purlins are needed every 4 to 5 m across the building to support the rafters;
the plain rafter roof was built with rafter lengths up to 4.5 m, longer rafters got a collar beam or purlins. — Holzbausanierung beim Bauen im Bestand 3.2.1.1 and Tab. 3.1 (a typology of built roofs, not a design rule).
- Typical: purlins, posts and rafters form a frame (Gebinde); the frames stand about 3.5 to
4.5 m apart. — same book 5.4.4.
- Confirmed (DIN EN 1995-1-1/NA, NA.13.2): battens may be taken to brace rafters only with
rafter spacing e ≤ 1.25 m, rafter width b ≥ 40 mm and depth h ≤ 4·b. — Wendehorst Bautechnische Zahlentafeln Tab. 12.24. An example build-up uses rafters 16/8 at a rafter spacing of 60 cm. — Bausanierung Abb. 10.1.
S.2 Sections
- Preferred sections of structural solid timber (KVH, C24), width b: depths h in cm —
6: 10/12/14/16/18/20/22/24; 8: 12/16/18/20/22/24; 10: 10/16/20/24; 12: 12/16/20/24; 14: 14. — Wendehorst Bautechnische Zahlentafeln Tab. 12.111 (state 09/2015).
- Rule of thumb: sections of good static use have b/h = 1:2; squared timber has sides
of at least 6 cm. — Zahlentafeln für den Baubetrieb 1.6.2 (p. 32).
- Typical: for insulation between and under the rafters choose a rafter depth of 16 to
20 cm. — Sanierung von baulichen Anlagen 4.3.5.2.
S.3 Defaults of this library for the purlin roof of a simple house
Not from a book. These are choices of this library, made so that a simple house can be modelled at all where the literature gives a frame and no number. Tier T4, massing only: any plan clause, product sheet, engineer's or carpenter's figure replaces them, and nothing here is a design value.
- Rafter spacing 0.80 m: between the 60 cm of the example and the 1.25 m bracing limit of S.1.
- Rafter depth from the joist ratio of §2.3, rounded up in steps of 2 cm from 16 cm (the
depths of the row of width 8 in S.2).
- Purlin of width 12 cm: depth from the glulam ratio of §2.3, at least 16 cm, rounded up in
steps of 4 cm (the row of width 12 in S.2).
- Posts 12/12 cm and eaves plate (Fußpfette) 12/12 cm: a preferred section of S.2.
- Collar beams (Kehlbalken) under a ceiling to the loft (
building-planning-spatial3.4): one
on every rafter, at the level of that ceiling, as wide as the rafters, the depth by the same rule as theirs over the span between the two slopes.