<< All versions

Skill v1.0.1

currentAutomated scan100/100
gptomics/bioskills/fcs-handling

1 files

──Details
PublishedAugust 27, 2026 at 03:11 AM
Content Hashsha256:e98b1389e4db10e6...
Git SHAd91ed3d56301
Bump Typepatch
Compare with v1.0.0
──Files
Files (1 file, 9.6 KB)
SKILL.md9.6 KBactive
SKILL.md · 159 lines · 9.6 KB

version: "1.0.1" name: bio-flow-cytometry-fcs-handling description: Reads, inspects, and writes Flow Cytometry Standard (FCS) files from conventional, spectral, and mass cytometry (CyTOF), and parses FlowJo/Cytobank/Diva workspaces. Covers FCS 2.0/3.0/3.1/3.2 internals ($PnE linear-vs-log, $DATATYPE, $SPILLOVER vs SPILL vs $COMP, $TIMESTEP), channel/parameter metadata, the silent linearize/truncate defaults, and R (flowCore, flowWorkspace, CytoML) plus Python (FlowKit, readfcs) readers. Use when loading flow or mass cytometry data, mapping detector channels to antibodies, extracting the event matrix, choosing a reader, or bridging FCS to the scanpy/AnnData ecosystem before preprocessing. tool_type: mixed primary_tool: flowCore


Version Compatibility

Reference examples tested with: flowCore 2.14+, flowWorkspace 4.14+, CytoML 2.14+; Python flowkit 1.1+, readfcs 1.1+.

Before using code patterns, verify installed versions match. If versions differ:

  • R: packageVersion('<pkg>') then ?function_name to verify parameters
  • Python: pip show <package> then help(module.function) to check signatures

If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.

FCS File Handling

"Load my FCS files and inspect the channels" -> Parse FCS format into event matrix + parameter metadata, map detector channels to antibodies, and choose a reader appropriate to the instrument and downstream ecosystem.

  • R: flowCore::read.FCS() / read.flowSet() -> flowFrame/flowSet; CytoML::flowjo_to_gatingset() for FlowJo workspaces
  • Python: flowkit.Sample() (full workflow) or readfcs.read() -> AnnData (scanpy/scverse bridge)

The Single Most Important Modern Insight -- read.FCS Silently Transforms by Default

flowCore::read.FCS() defaults to transformation = "linearize", which APPLIES the $PnE log-amplification scaling on read. Two pipelines reading "the same raw FCS" (flowCore default vs fcsparser/transformation=FALSE) therefore return different numbers, and a compensation matrix computed on one will silently mismatch the other. For any preprocessing pipeline that will compensate and transform downstream, read with transformation = FALSE (or NULL) to get the genuinely raw values, and set truncate_max_range = FALSE so out-of-$PnR events (common on CyTOF and some digital instruments) are not silently clipped. Decide the read settings deliberately; they are not nuisance defaults.

FCS Standard Internals (what the keywords mean)

KeywordMeaningDecision-relevant nuance
$PnEamplification type "decades,offset""0,0" = linear; FCS 3.1 FORBIDS log-stored floats (a float param must be "0,0"); log $PnE survives only on legacy integer analog-log data
$DATATYPEI (uint) / F (float) / D (double) / A (ASCII, deprecated 3.1)FCS 3.2 allows MIXED types per parameter via $PnDATATYPE (integer Time + float fluorescence)
$PnRparameter rangefor integers defines the bit mask via next power of two ($PnR=1024 -> 10-bit), NOT a value clamp
$SPILLOVERstandardized compensation matrix (3.1+)digital BD instruments wrote non-standard SPILL (no $); 3.0 $COMP stored a matrix WITHOUT naming parameters (ambiguous -> why $SPILLOVER exists)
$TIMESTEPseconds per Time-channel unitthe master axis for all time-based QC; missing/wrong $TIMESTEP silently breaks flow-rate/drift checks

FCS standards: 3.0 (Seamer 1997 Cytometry 28:118), 3.1 (Spidlen 2010 Cytometry A 77:97), 3.2 (Spidlen 2021 Cytometry A 99:100). Area/Height/Width = pulse integral/peak/duration; FSC-A vs FSC-H is the doublet axis. CyTOF channels are <Metal><Mass>Di (e.g. Yb176Di) and report dual counts (pulse-counting at low signal, intensity at high).

Reader Taxonomy

ReaderLanguageWhat it doesWhen to use
flowCore::read.FCS/read.flowSetRcore FCS -> flowFrame/flowSetthe default for any R/Bioconductor pipeline
flowWorkspace GatingSetRgated hierarchy containerwhen carrying gates/populations
CytoMLRFlowJo (wsp) / Cytobank / Diva import-exportround-tripping a manual analysis (Finak 2018 Cytometry A 93:1189)
flowkit (Session/Sample)PythonFCS + GatingML 2.0 + FlowJo wsp + compensation/transformsPython pipelines, FlowJo interop (White 2021 Front Immunol 12:768541)
readfcsPythonFCS -> AnnDatabridge to scanpy/scverse and the single-cell categories
fcsparser / FlowCalPythonlow-level reader / reader + MEF calibrationquick parse; FlowCal for MESF/MEF work

Load and Inspect FCS (R)

Goal: Read one file (or a directory) raw, inspect parameters, and map channels to antibodies.

Approach: Read with transformation=FALSE, truncate_max_range=FALSE; the channel->antibody map lives in pData(parameters(fcs)) (name = detector, desc = antibody).

r
library(flowCore)
fcs <- read.FCS('sample.fcs', transformation = FALSE, truncate_max_range = FALSE)
params <- pData(parameters(fcs)) # name (detector), desc (antibody), range, minRange
channel_map <- setNames(params$desc, params$name)
fs <- read.flowSet(list.files('data', pattern = '\\.fcs$', full.names = TRUE),
transformation = FALSE, truncate_max_range = FALSE)
expr <- exprs(fcs) # cells x channels

Access the Compensation Matrix from Keywords

Goal: Retrieve the acquisition-recorded spillover matrix, handling the three keyword conventions.

Approach: Try $SPILLOVER, then the legacy SPILL, then $COMP; flowCore::spillover() resolves the standard slots.

r
kw <- keyword(fcs)
spill <- kw$`$SPILLOVER`
if (is.null(spill)) spill <- kw$SPILL # digital BD convention
if (is.null(spill)) spill <- kw$`$COMP` # legacy FCS 3.0 (unnamed columns)

Load FCS in Python (FlowKit / readfcs)

Goal: Read FCS in a Python pipeline, either for FlowKit's compensation/gating or as an AnnData for scanpy.

Approach: flowkit.Sample exposes raw/compensated/transformed events as DataFrames; readfcs.read returns AnnData with channels in var.

python
import flowkit as fk
import readfcs
sample = fk.Sample('sample.fcs')
events = sample.as_dataframe(source='raw') # source in {'raw','comp','xform'}
adata = readfcs.read('sample.fcs') # AnnData; adata.var has channel + antibody names

Rename Channels, Subset, Write, Annotate Samples

Goal: Standardize channel names to antibodies and attach sample-level metadata for downstream tools.

Approach: Replace blank desc with name; attach a pData table keyed by sampleNames(fs) (CATALYST/diffcyt require this).

r
new <- ifelse(is.na(params$desc) | params$desc == '', params$name, params$desc)
colnames(fcs) <- new
fcs_markers <- fcs[, c('CD4', 'CD8', 'CD3')] # subset channels
write.FCS(fcs, 'out.fcs')
pData(fs) <- data.frame(name = sampleNames(fs),
condition = c('Control','Control','Treatment','Treatment'),
patient = c('P1','P2','P1','P2'),
row.names = sampleNames(fs))

Per-Method Failure Modes

Silent log-linearization on read

Trigger: read.FCS('x.fcs') with default args. Mechanism: transformation="linearize" applies $PnE scaling. Symptom: values differ from fcsparser; compensation matrix mismatch. Fix: transformation = FALSE.

Out-of-range clipping

Trigger: instrument wrote values above $PnR (common CyTOF). Mechanism: truncate_max_range=TRUE (default) clamps them. Symptom: a ceiling artifact at the channel max. Fix: truncate_max_range = FALSE.

Channel names break formulas

Trigger: channels like FSC-A, Pacific Blue-A. Mechanism: hyphens/spaces are not syntactic R names. Symptom: formula/gating errors. Fix: alter.names = TRUE on read.

FlowJo parsing in the wrong package

Trigger: looking for FlowJo import in flowWorkspace. Mechanism: parsing lives in CytoML. Symptom: function-not-found. Fix: CytoML::open_flowjo_xml() -> flowjo_to_gatingset(); only .wsp (FlowJo 10+), not legacy .jo.

Common Errors

Error / symptomCauseSolution
exprs() numbers differ across toolsdefault linearizeread with transformation=FALSE everywhere
spillover keyword is NULLinstrument used SPILL/$COMPtry all three keyword names
editing exprs(ff) corrupts rangesdirect reassignment skips parameters() updateuse transform/Subset workflows
readfcs compensation not appliedmatrix names don't match var_namesalign channel names before relying on it

References

  • Seamer 1997 Cytometry 28(2):118-122 — FCS 3.0 standard.
  • Spidlen 2010 Cytometry A 77(1):97-100 — FCS 3.1 standard.
  • Spidlen 2021 Cytometry A 99(1):100-102 — FCS 3.2 standard.
  • Finak 2018 Cytometry A 93(12):1189-1196 — CytoML cross-platform gating import/export.
  • White 2021 Front Immunol 12:768541 — FlowKit Python toolkit.
  • Lee 2008 Cytometry A 73(10):926-930 — MIFlowCyt minimum reporting standard.

Related Skills

  • compensation-transformation - Compensate and transform after loading
  • cytometry-qc - Assess acquisition quality on the loaded data
  • gating-analysis - Define populations from the loaded GatingSet
  • clustering-phenotyping - Unsupervised analysis of the event matrix
  • single-cell/data-io - readfcs bridges FCS to the AnnData/scanpy ecosystem
  • imaging-mass-cytometry/data-preprocessing - Shared metal-channel and FCS conventions
← v1.0.0All versions