h30190/hjplus_taiwan_architect_kb/balcony-lobby-far-recalculation
Claude Code and agent skill by h30190/hjplus_taiwan_architect_kb
- community
Checking that the SKILL.md file is still in the repository.
This skill should be used when calculating Taiwan FAR gross-floor-area inclusion for balcony and shared stair/elevator lobby areas under Building Technical Regulations Article 162, including the separate 10% balcony cap, separate 10% lobby cap, combined 15% balcony-plus-lobby cap, and avoiding double-counting already-included excess area.
Install
npx vskill@latest install h30190/hjplus_taiwan_architect_kb/balcony-lobby-far-recalculationSKILL.md
Balcony and Lobby FAR Recalculation
Overview
Use this skill when reviewing Taiwan building-permit FAR calculations for:
- Balcony area (陽臺面積) exemption up to 10% of the floor area
- Shared stair/elevator lobby area (梯廳面積) exemption up to 10% of the floor area
- Combined balcony plus lobby exemption up to 15% of the floor area
- Recalculated area that must be included in FAR gross floor area (回計容積面積)
The key practitioner issue is avoiding double-counting: once balcony or lobby area has already exceeded its own 10% cap and has been included in FAR, the combined 15% check should use only the remaining exempt candidates, not the original raw balcony plus lobby total.
Legal Basis
Building Technical Regulations, Design and Construction, Article 162, Paragraph 1, Subparagraph 1:
- Balcony area within 10% of that floor's area may be excluded from FAR gross floor area.
- Shared stair/elevator lobby area within 10% of that floor's area may be excluded, provided the lobby clear depth is at least 2 m.
- If balcony plus lobby area exceeds 15% of that floor's area, the excess must be included.
Always verify local review-sheet conventions and current official text before final filing.
Inputs
| Symbol | Meaning | |
|---|---|---|
F | Floor area for the reviewed story | |
B | Total balcony area for the story | |
L | Total eligible shared stair/elevator lobby area for the story | |
Cap10 | F * 0.10, rounded to two decimals before use | |
Cap15 | F * 0.15, rounded to two decimals before use |
Only include lobby area in L after confirming the lobby meets basic eligibility, especially the 2 m finished clear-depth requirement.
Algorithm
Review Logic
- Check balcony against the 10% cap and record balcony excess.
- Check lobby against the 10% cap and record lobby excess.
- Cap each item at its 10% exempt candidate before the combined 15% check.
- Check
min(B, Cap10) + min(L, Cap10)againstCap15. - Add the two separate 10% excess values and the combined 15% excess value.
Do not calculate separate 10% excess first and then check raw B + L against 15%, because that can include the same excess area twice.
Decimal Handling
Use one decimal convention throughout the calculation sheet:
- Round
Cap10 = F * 0.10to two decimal places before using it as the 10% exemption cap. - Round
Cap15 = F * 0.15to two decimal places before using it as the combined 15% exemption cap. - Use the rounded
Cap10to split each item, soexempt area + included excess area = original balcony or lobby areain the review table. - Display other output fields to two decimal places.
Use the usual half-up engineering-table convention for midpoint cases.
Worked Examples
Example A
With two-decimal rounding, report 3.43 m2.
Example B
With two-decimal rounding, report 9.68 m2.
Example C: Both Items Exceed 10%
This preserves the 15% final exempt ceiling without double-counting the 20 m2 that was already included by the separate 10% checks.
Validation Cases
Use these cases to verify that each 10% item split satisfies exempt + included = original area after the 10% cap is rounded.
| Case | F | Cap10 | Item | Original | Exempt | Included | Sum | |
|---|---|---|---|---|---|---|---|---|
| A lobby over 10% | 752.58 | 75.26 | Lobby | 78.69 | 75.26 | 3.43 | 78.69 | |
| A balcony under 10% | 752.58 | 75.26 | Balcony | 2.70 | 2.70 | 0.00 | 2.70 | |
| B lobby under 10% | 447.48 | 44.75 | Lobby | 40.37 | 40.37 | 0.00 | 40.37 | |
| B balcony under 10% | 447.48 | 44.75 | Balcony | 36.43 | 36.43 | 0.00 | 36.43 | |
| Exactly rounded 10% cap | 333.35 | 33.34 | Lobby | 33.34 | 33.34 | 0.00 | 33.34 | |
| Just above rounded 10% cap | 333.35 | 33.34 | Balcony | 33.35 | 33.34 | 0.01 | 33.35 | |
| Both items over 10% | 500.00 | 50.00 | Lobby | 62.00 | 50.00 | 12.00 | 62.00 | |
| Both items over 10% | 500.00 | 50.00 | Balcony | 58.00 | 50.00 | 8.00 | 58.00 |
Output Checklist
- Confirm lobby clear depth and eligibility before including lobby area as an exempt candidate.
- Show
Cap10andCap15for each floor. - Show separate balcony and lobby 10% excess values.
- Show combined 15% excess using the capped exempt candidates.
- State the decimal rule: round
Cap10andCap15to two decimals before using them as caps.
Tool Examples
taiwan-building-code_search_building_code(query: "建築技術規則 第162條 陽臺 梯廳 百分之十五", limit: 5)taiwan-building-code_search_building_interpretations(query: "陽臺 梯廳 容積 15%", limit: 5)
References
- Building Technical Regulations, Design and Construction, Article 162: FAR gross-floor-area calculation and exemption items
- Local building-permit FAR calculation sheets and review conventions
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingraw/建築法規/容積率與建蔽率計算/陽臺梯廳回計容積計算/balcony-lobby-far-recalculation/SKILL.md
Popularity
- Repository stars
- 167
- Repository forks
- 136
- 7-day trend score
- 0
Stars and forks are for the whole GitHub repository, not this skill alone. Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/h30190/hjplus_taiwan_architect_kb/balcony-lobby-far-recalculation)