version: "1.0.1" description: > Prognostic assessment workflow: trend analysis, degradation onset detection, and Remaining Useful Life (RUL) estimation using the predictive-maintenance-mcp server. Use this skill when the user says "trend analysis", "degradation trend", "RUL", "remaining useful life", "prognosis", "prognostics", "failure prediction", "time to failure", "degradation onset", "predict failure", "vita utile residua", "previsione guasto", "quanto dura", "stima vita", or asks to predict when a component will fail based on vibration data.
Prognostic Assessment (ISO 13374 Block 5)
Screen degradation trends within a recording and estimate Remaining Useful Life from repeated measurements over time. Two distinct scopes — do not confuse them:
- Within-recording screening (
analyze_signal_trend): is this single
recording stationary, or does a feature drift inside it? This is a screening result, NOT a prognosis.
- Prognosis (
estimate_rul): extrapolation of a degradation trend
across MULTIPLE measurements of the same machine taken days/weeks/months apart. RUL from a single recording is physically meaningless and the tool refuses it.
RUL estimates are planning input for the maintenance engineer — never a guarantee, never a substitute for engineering judgment.
Prerequisite: The predictive-maintenance-mcp MCP server must be connected.
Workflow A — Within-Recording Screening
Step 1 — Signal Discovery
Call list_signals(scope="memory") for loaded signal_ids, or list_signals(scope="disk") and load_signal(filepath="<file>") to load a recording. This works best on long monitoring recordings or run-to-failure data where degradation evolves within the file. For raw binary files (.bin/.raw/.dat), also declare sample_format and sampling_rate (or provide a companion <stem>_metadata.json) — see the signal-management skill.
Step 2 — Trend + Onset Screening (one call)
Call analyze_signal_trend(signal_id="<id>", feature_name="rms").
The tool segments the recording, extracts the chosen feature per segment, tests trend significance (slope p-value, not bare R-squared), and detects the first post-baseline segment exceeding baseline mean + N sigma — trend AND onset in one result.
Parameters:
feature_name:"rms"(default),"kurtosis","crest_factor",
"peak_to_peak", ...
segment_duration(default 0.1 s) andoverlap_ratio(default 0.5)onset_threshold_sigma: baseline standard deviations that trigger onset
detection (default 3.0; lower to 2.0 for more sensitivity, with more false positives)
Feature guidance:
| Indicator | Use when | Notes | |
|---|---|---|---|
| rms | General degradation | Most common, ISO 20816 aligned | |
| kurtosis | Bearing degradation | Peaks early, then may drop | |
| crest_factor | Impulsive faults | Sensitive to early damage | |
| peak_to_peak | Looseness, imbalance | Good for mechanical looseness |
Interpreting the result:
trend_directionis decided by the slope p-value (< 0.05), not by eyeanalysis_scopeis"within_recording_screening"— report it as such- Onset fields:
onset_detected,onset_segment_index,onset_time_s,
baseline_segments. Onset inside the baseline window (first half) cannot be detected by construction — say so if the user asks
- The result includes the (truncated) per-segment
feature_series: use it to
reduce this recording to ONE measurement point for Workflow B
Decision gate: if the trend is stable or decreasing, report that no degradation trend is detected within the recording. Do NOT proceed to RUL on this basis alone.
Workflow B — RUL from Repeated Measurements
Step 1 — Assemble a Measurement Series
RUL needs at least 3 measurements of the same machine over time, as either:
- Externally measured values (e.g. RMS velocity trended by a data
collector): pass them directly as feature_values.
- One stored recording per measurement session: load each session's
file (batch load works: load_signal(filepath=["session_day0.csv", "session_day7.csv", "session_day14.csv"], signal_unit="mm/s")) and pass the ids as signal_ids — each recording is reduced to a single feature value.
Timestamps are required, one per measurement, strictly increasing, in the unit you choose (time_unit, default "hours").
Step 2 — Choose the Failure Threshold
Ask the user — do NOT guess. If the indicator is broadband velocity RMS in mm/s, the ISO zone C/D boundary for the machine is the standard choice (the same table assess_severity uses): 4.5 (group 2 rigid), 7.1 (group 1 rigid / group 2 flexible), or 11.0 mm/s (group 1 flexible). A site maintenance policy threshold also works.
Step 3 — Estimate
Call estimate_rul(feature_values=[2.1, 2.4, 2.9, 3.5], timestamps=[0, 168, 336, 504], failure_threshold=4.5, time_unit="hours", method="linear")
or, from stored recordings:
Call estimate_rul(signal_ids=["session_day0", "session_day7", "session_day14"], timestamps=[0, 7, 14], failure_threshold=4.5, feature_name="rms", time_unit="days")
Method choice:
"linear"— steady degradation (default)"exponential"— accelerating degradation curves"kalman"— needs approximately uniform measurement spacing; also returns
a 95% RUL interval
Step 4 — Interpret the Result Honestly
Possible statuses:
"estimated": RUL intime_unit, withfit_r_squared(goodness of fit —
NOT a confidence) and observation_horizon. If RUL extends far beyond the observed horizon, the result says so — relay that caution verbatim
"no_degradation_trend": flat/insignificant series — no RUL number is
produced. Recommend continuing to collect measurements
"threshold_already_exceeded": the last measurement is at/above the
threshold — inspection is due now, there is no remaining life to estimate
Report: trend significance (p-value), fit quality, RUL with its time unit, observation horizon, and urgency relative to the next maintenance window.
Important Notes
- RUL estimates are extrapolations — actual failure time depends on
operating conditions that may change
- Always use cautious language: "estimated RUL", "projected time to threshold"
fit_r_squaredmeasures curve fit, not probability of being right- A single recording can NEVER produce an RUL — if the user asks, explain why
and offer Workflow A screening plus a measurement-collection plan
- This skill supports expert maintenance scheduling decisions; it does not
replace engineering judgment
- All processing happens locally — raw signal data never leaves the machine