matlab/simulink-agentic-toolkit/specifying-plant-models

Claude Code and agent skill by matlab/simulink-agentic-toolkit

Trust tier 2
  • community
LLM review pending
Source check pending

Checking that the SKILL.md file is still in the repository.

Specify plant models for closed-loop simulation: system specs, architecture, build plans, validation plans. Use when creating, updating, or reviewing plant model specifications, planning plant model architecture, or planning plant model validation.

Install

npx vskill@latest install matlab/simulink-agentic-toolkit/specifying-plant-models

SKILL.md

Plant Model Specs

Structured specification of plant models for closed-loop simulation. Adapts the specifying-software templates for the physics-modeling domain.

When to Use

  • Creating a plant model to close the loop with an existing controller
  • Updating or extending an existing plant model spec
  • Specifying a plant model before building it
  • Deciding on model architecture (subsystem decomposition, fidelity level)
  • Planning validation of a plant model

When NOT to Use

  • Building the plant model → use building-simulink-models
  • Testing an existing plant model → use testing-simulink-models
  • Specs for controller algorithms or MBD algorithms → use specifying-mbd-algorithms
  • Specs for traditional software (C, C++, Python, MATLAB scripts) → use specifying-software
  • Specifying a full closed-loop system → use specifying-mbd-algorithms for the algorithm side, this skill for the plant side

Output Conventions

Store specs per plant model. Prefix every filename with the plant name so files are self-identifying in editor tabs, search results, and flat listings:

docs/specs/plant-models/<plant-name>/
├── <plant-name>-system.md # What & why
├── <plant-name>-architecture.md # Subsystem decomposition
├── <plant-name>-implementation-plan.md # Build sequence
└── <plant-name>-test-plan.md # Validation plan

Example for a plant called motor:

docs/specs/plant-models/motor/
├── motor-system.md
├── motor-architecture.md
├── motor-implementation-plan.md
└── motor-test-plan.md

Mode Selection

Does this plant have <5 states, single-rate dynamics, no strong nonlinearities, and will be built by one person/agent?
- Yes → Quick spec: 2 documents (system+architecture combined, implementation+test combined)
- No → Full spec: 4 separate documents
Document Boundaries
SpecAnswersDoes NOT Contain
SystemWhat are we building and why?Subsystem decomposition, equations
ArchitectureHow is it structured?Simulink block details, parameter values
Implementation PlanHow do we build it?Actual model_edit commands
Test PlanHow do we validate it?Test execution results

In quick mode, combine system+architecture and implementation+test into two documents.

Workflow

Step 1: Analyze Controller Interface

Read the controller model with model_overview and model_read. Classify every signal as:

  • u (commanded inputs from controller), w (exogenous disturbances),
  • y (measured outputs to controller, with sensor effects), z (truth outputs for debugging)

Define the plant boundary and document sample times.

Step 2: Assess Validation Evidence

Before researching the domain, establish what evidence exists: test data, datasheets, standard maneuvers, analytic expectations, reference models.

Fidelity must be justified by available evidence — no point modeling dynamics you can't validate. Intended use matters: MIL rapid iteration → lower fidelity acceptable; HIL/code generation → fixed-step, real-time constraints.

Step 3: Research the Physics Domain

Use web_search and read_web_page for standard modeling approaches, reference parameters, and authoritative sources. Consult references/plant-model-guidance.md for cross-domain patterns if needed.

Step 4: Write System Spec

Use assets/system-spec-template.md. Key plant-model sections: operating scenarios, physical model requirements, controller interface contract (u/w/y/z with sample times, data types, units), initialization & operating points, rate & timing alignment, validation evidence, reference sources.

Review gate before proceeding — verify:

  • Completeness of interface requirements (u, y signals covered)
  • Appropriate fidelity given intended use AND available validation evidence
  • Coverage of controller's operating envelope in operating scenarios
  • Operating points / initialization strategy specified and feasible
  • Rate/sample time alignment with controller defined
  • Clear validation reference for each major requirement

Get user review before proceeding.

Step 5: Write Architecture Spec

Use assets/architecture-spec-template.md. Key plant-model sections: component catalog with physics domain and port interfaces, equations of motion per subsystem, nonlinearities & constraints, numerical considerations (solver, stiffness, algebraic loops), parameter management, uncertainty hooks.

Review gate before finalizing — verify:

  • Correct physics decomposition — subsystem boundaries at natural domain boundaries
  • Complete signal flow from u through dynamics to y
  • Disturbances w entering at the right points
  • Consistent interfaces: units, sign conventions, coordinate frames end-to-end
  • DAE / algebraic loop risks addressed; conservation laws respected
  • Missing dynamics that affect the controller (actuator limits, sensor noise, transport delays)

Get user review before proceeding.

Step 6: Write Implementation Plan + Test Plan

Use assets/implementation-plan-template.md and assets/test-plan-template.md.

Implementation plan essentials:

  • Phase 0 (interface contract & stubs) gates all parallel work — freeze ports/units/sign conventions first
  • Loosely coupled subsystems (sensors, actuators, load, environment) can be built by separate agents concurrently after Phase 0; tightly coupled splits (inverter↔motor, tire↔chassis) need coordination
  • Model References enable the strongest parallel development (separate .slx files)
  • Parameter table: every parameter with name, value, unit, source, block path
  • Sync points use model_read verification and model_query_params spot-checks

Test plan essentials:

  • Three-stage validation: subsystem open-loop → integrated open-loop → closed-loop
  • Input signal definitions with parameters (step, ramp, sine sweep)
  • Gherkin scenarios mapped to model_test format
  • Quantitative acceptance criteria with physical justification

Review gate — Implementation Plan — verify:

  • Realistic bottom-up build order (leaf subsystems first)
  • Phase 0 interface stubs gate parallel work
  • Correct Simulink block types for the physics
  • Solver choice matches stiffness + discrete elements
  • Complete parameter table with sources and units

Review gate — Test Plan — verify:

  • Validation staging: subsystem open-loop → integrated open-loop → closed-loop (MIL)
  • Real-time execution feasibility assessed if plant is HIL-targeted
  • Each maneuver specifies: input, outputs, comparison method, acceptance criteria
  • Parameter sensitivity checks included
  • Numerical robustness test (solver tolerance, step size)
  • Gherkin scenarios executable via model_test

Get user approval before building begins.

Guardrails

Always
  • Classify signals as u/w/y/z at every interface
  • Cite sources for every parameter (value, unit, source, uncertainty, conditions)
  • Assess validation evidence before choosing fidelity level
  • Decompose into subsystems at natural domain boundaries (actuator, dynamics, sensor, environment, load)
Ask First
  • Fidelity level changes after system spec is approved
  • Adding subsystems not in the architecture spec
  • Deviating from the controller's sample time alignment
Never
  • Reproduce textbook derivations in specs — cite authoritative sources instead; use web_search for domain-specific research
  • Model dynamics you cannot validate against available evidence
  • Skip Phase 0 interface stubs when parallel building is planned
  • Use web_search results from unvetted sources — prefer standards, textbooks, MathWorks docs, and peer-reviewed papers

References

  • assets/system-spec-template.md — System spec template (what & why)
  • assets/architecture-spec-template.md — Architecture template (subsystem decomposition)
  • assets/implementation-plan-template.md — Build sequence template
  • assets/test-plan-template.md — Validation plan template
  • references/plant-model-guidance.md — Optional domain reference (decomposition examples, validation maneuvers, solver guide). Human-facing; do not copy verbatim into specs.

Copyright 2026 The MathWorks, Inc.


Security

  • Security scanPassed, 100 of 100Pattern checks on the skill's files.
  • Model reviewNot runA model review is scheduled for the next rescan.

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

Repository stars
1,035
Repository forks
99
7-day trend score
35

Stars and forks are for the whole GitHub repository, not this skill alone. Refreshed 16 May 2026, 6 months ago.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/matlab/simulink-agentic-toolkit/specifying-plant-models/badge)](https://verified-skill.com/skills/matlab/simulink-agentic-toolkit/specifying-plant-models)

Something wrong with this skill or its page? Tell us.