wedsamuel1230/arduino-skills/sensor-calibration-workbench

Claude Code and agent skill by wedsamuel1230/arduino-skills

Trust tier 3
  • community
Source check pending

Checking that the SKILL.md file is still in the repository.

Use when makers need calibration workflows for sensors such as CO2 sensors, load cells, magnetometers, color sensors, or analog sensors, including warm-up behavior, reference measurements, coefficient storage, and drift checks.

Install

npx vskill@latest install wedsamuel1230/arduino-skills/sensor-calibration-workbench

SKILL.md

Sensor Calibration Workbench

Use this skill when the sensor technically works, but the readings are not yet trustworthy enough for the project.

Resources

  • references/calibration-flow.md - end-to-end calibration workflow and evidence checklist
  • references/common-failure-patterns.md - warm-up, scaling, drift, saturation, and environment mistakes
  • references/persistence-and-revalidation.md - storing coefficients and deciding when recalibration is needed

When to Use

Use this skill when the request involves:

  • volatile or implausible sensor readings
  • "how do I calibrate this sensor?"
  • load-cell factor tuning
  • CO2, magnetometer, or color-sensor calibration
  • storing calibration coefficients in EEPROM or flash
  • deciding whether the problem is calibration, hardware, or environment

Do not use this skill when the sensor is not detected at all. That should route through hardware or bus bring-up first.

Workflow

  1. Confirm the measurement problem:
  • unstable -> open references/common-failure-patterns.md
  • offset or scaling error -> open references/calibration-flow.md
  • values good once but bad later -> open

references/persistence-and-revalidation.md

  1. Identify the calibration class:
  • one-point or zero-offset
  • two-point scale calibration
  • multi-orientation or environmental calibration
  1. Collect reference evidence before changing coefficients:
  • known reference values
  • warm-up state
  • ambient conditions
  • sample stability
  1. Decide how calibration values will persist and how revalidation will be

triggered after reboot, firmware update, or field drift.

Core Rules

  • Calibration without a known reference is guesswork.
  • Warm-up and stabilization time are part of calibration, not a side note.
  • Do not mix hardware-fault symptoms with coefficient-tuning symptoms.
  • Store both the calibration values and enough metadata to know when they became

stale.

Verification

  • Confirm readings converge toward a known reference after calibration.
  • Confirm the calibrated values stay stable across repeated samples.
  • Confirm stored coefficients reload correctly after restart.
  • If the project has operating thresholds, verify those thresholds against the

calibrated output rather than the raw sensor value.

Integration

  • Pair with i2c-bringup-diagnostician or circuit-debugger when the sensor is

not yet electrically trustworthy.

  • Pair with arduino-code-generator when the user needs persistence or

filtering code added to the sketch.

  • Pair with field-power-and-connectivity-triager when sensor behavior changes

only off USB or under field power conditions.

Shared Output Contract

Use the shared Arduino skill contract: state assumptions, required tools and versions, implementation steps, tests/evidence by proof stage, known limitations, and recovery/security notes.

Security

  • Security scanPassed, 95 of 100Pattern checks on the skill's files.
  • Model reviewPassed

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

7-day trend score
5

Not refreshed yet.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/wedsamuel1230/arduino-skills/sensor-calibration-workbench/badge)](https://verified-skill.com/skills/wedsamuel1230/arduino-skills/sensor-calibration-workbench)

Something wrong with this skill or its page? Tell us.