agisota/old-one/fda-qsr-audit-prep
Claude Code and agent skill by agisota/old-one
- community
Checking that the SKILL.md file is still in the repository.
/cs:fda-qsr-audit-prep <scope> — FDA 21 CFR 820 (QSR / QMSR) audit 6-question forcing interrogation. Post-Feb 2026 substantially harmonized with ISO 13485. Use before annual internal QSR audit, pre-FDA-inspection readiness, or Form 483 response.
Install
npx vskill@latest install agisota/old-one/fda-qsr-audit-prepSKILL.md
The same SKILL.md was published earlier as agisota/old-one/fda-qsr-audit-prep.
/cs:fda-qsr-audit-prep — FDA QSR Forcing Questions
Command: /cs:fda-qsr-audit-prep <scope>
The FDA QSR auditor pressure-tests any US medical-device QSR work. Six questions before any internal audit, FDA inspection, Form 483 response, or recall decision.
When to Run
- Before annual internal QSR audit
- Before pre-FDA-inspection readiness review (any device commercially distributed in US)
- After receiving Form 483 observations
- After Warning Letter receipt
- After MDR-reportable event
- Before recall decision (voluntary vs FDA-initiated)
- Before submitting 510(k) / PMA (where QSR posture affects approval timeline)
The Six QSR Questions
1. Show me the complaint files from the last quarter — and the corresponding MDR reports.
21 CFR 820.198 + 21 CFR 803 — most-cited FDA inspection area.
- Complaint log complete: who / what / when / device / batch
- Investigation closure within reasonable timeline
- MDR-reporting decision tree applied: death OR serious injury OR malfunction-that-could-cause = MDR
- 30-day timeline for most MDR reports; 5 days for certain serious events
- Complaint trending input to management review
2. When was process validation (IQ/OQ/PQ) last revalidated per 21 CFR 820.75?
Cross-walks ISO 13485 Clause 7.5.6 (substantially harmonized post-Feb 2026).
- Initial validation at process introduction
- Revalidation triggers: process / equipment / material change OR periodic schedule
- Statistical techniques per 21 CFR 820.250 where applicable
- Cross-check with cs-cqm-iso13485 for ISO 13485 alignment
3. Show me the DHRs for products commercially distributed in last 2 years.
21 CFR 820.180 — 2-year retention from commercial distribution; check sampling for completeness.
- Device History Record (DHR) for each unit/lot/batch
- Must include: dates of manufacture, quantity manufactured, quantity released, acceptance records, primary identification label, device identification, control number
- Sample stratified by product class
- Verify DHR closeness to DHF (design history file)
4. Show me CAPAs from the last 6 months with effectiveness verification.
21 CFR 820.100 = ISO 13485 8.5.2 substantially harmonized.
- Root cause analysis depth (5 Why minimum)
- Effectiveness verification = measurable evidence, not "we updated the procedure"
- Containment / correction / corrective action distinction documented
- Closure approval by appropriate authority
- Aging CAPAs > 90 days flagged
5. Show me labeling (21 CFR 801) review for the most recent product launch.
FDA-specific overlay not in ISO 13485.
- Labeling per 21 CFR 801 requirements
- For specific device types: also 21 CFR 800 series sectoral overlays
- UDI (Unique Device Identification) per 21 CFR 830
- Promotional materials reviewed for accuracy + non-misleading
6. If a Form 483 was issued in the last 3 years, show me the closure status.
Form 483 = FDA observation; not equivalent to ISO nonconformity.
- Response within 15 working days
- Each observation has documented corrective + preventive action with timeline
- Effectiveness verification evidence
- For Warning Letters: separate response track + potentially FDA meeting
Workflow
Output Format
Routing
/cs:compliance-readiness— for multi-framework view/cs:iso13485-audit-prep— for ISO 13485 cross-walk pair (substantially harmonized)/cs:gdpr-audit-prep— if connected device handles personal data/cs:gc-review— for Warning Letter response coordination
Related
- Agent: `cs-fda-qsr-auditor`
- Skill: `fda-consultant-specialist`
- Adjacent:
../iso13485-audit-prep/,../compliance-readiness/
Version: 1.0.0
Security
- Security scanPassed, 90 of 100Pattern checks on the skill's files.
- Model reviewPassed
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/fda-qsr-audit-prep/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/agisota/old-one/fda-qsr-audit-prep)