aicodedecode/awesome-muse-skills/diagnostic-test-accuracy
Claude Code and agent skill by aicodedecode/awesome-muse-skills
- community
- ext:[{"type":"plugin","description":"Custom plugin integration"}]
Checking that the SKILL.md file is still in the repository.
Evaluating diagnostic tests — sensitivity, specificity, ROC analysis, likelihood ratios, and study design.
Install
npx vskill@latest install aicodedecode/awesome-muse-skills/diagnostic-test-accuracySemi-extensibleMentions customization, but needs skill-specific knowledge. Read the extensible skills standard
SKILL.md
The same SKILL.md was published earlier as aicodedecode/awesome-muse-skills/diagnostic-test-accuracy.
Overview
diagnostic-test-accuracy covers how to evaluate whether a test distinguishes disease from non-disease: study designs (cohort, case-control, with their biases), the core metrics (sensitivity, specificity, predictive values, likelihood ratios, ROC/AUC), and the reporting standards (STARD) that make accuracy studies credible. A test's accuracy in a paper and its usefulness in practice are different things — this skill keeps both in view.
When to use
- Designing a diagnostic accuracy study: population, reference standard, blinding.
- Computing and interpreting sensitivity, specificity, PPV/NPV, likelihood ratios.
- ROC analysis and AUC: what it means, when it misleads.
- Choosing cutoffs: Youden index, clinical utility, net benefit.
- Comparing two tests: paired designs, McNemar, ROC comparison.
- Appraising published accuracy studies for bias (QUADAS-2).
- Understanding why PPV collapses in low-prevalence screening.
Core concepts
- The 2×2 table. Sensitivity = TP/(TP+FN) (rule-out power; SnNOut). Specificity =
TN/(TN+FP) (rule-in power; SpPIn). These are properties of the test in a population — but they're estimated in a studied population, and spectrum effects mean they don't always travel.
- Predictive values depend on prevalence. PPV = probability of disease given a positive test.
Even a 99%-sensitive, 99%-specific test has PPV ~50% at 1% prevalence. This is the math behind every screening controversy — always compute predictive values at the prevalence where the test will actually be used.
- Likelihood ratios. LR+ and LR− convert pre-test odds to post-test odds and are the most
clinically useful single numbers. LRs >10 or <0.1 change probability decisively; LRs near 1 are useless regardless of statistical significance.
- ROC and AUC. The ROC curve plots sensitivity vs 1−specificity across cutoffs; AUC is the
probability a random diseased subject scores higher than a random healthy one. AUC 0.5 = useless, 0.7-0.8 = modest, >0.9 = excellent — but AUC averages over clinically irrelevant cutoff regions. Report partial AUC or sensitivity at clinically relevant specificity when it matters.
- Cutoff selection. The Youden index (max sens+spec−1) is statistically convenient but
clinically arbitrary — it weights false positives and negatives equally. Choose cutoffs by clinical consequences (missing disease vs false alarms), ideally via decision-curve/net-benefit analysis.
- Reference standard. Accuracy is measured against a reference ("gold") standard — which is
itself imperfect. Imperfect reference bias distorts everything; use composite references, expert panels, or latent-class analysis, and blind index-test interpreters to the reference (and vice versa).
- Design biases. Case-control (extreme cases vs healthy controls) inflates accuracy
(spectrum bias); partial verification (only positives get the reference test) inflates sensitivity; incorporating the index test into the reference standard is circular. The preferred design: consecutive patients with diagnostic uncertainty, all receiving index and reference tests, blinded.
- QUADAS-2 appraisal. Four domains: patient selection, index test, reference standard, flow
and timing. Use it to appraise any accuracy study before believing its numbers.
Practical workflow
- Define the clinical role. Triage, add-on, or replacement test? The role determines the
required accuracy profile and the comparator.
- Design. Consecutive eligible patients, prespecified index-test cutoff (or prespecified
method for choosing it), reference standard applied to all, blinded interpretation.
- Analyze. 2×2 table with 95% CIs (Wilson intervals); ROC/AUC; LRs; predictive values at
relevant prevalences; decision-curve analysis for clinical utility.
- Compare properly. Paired design when comparing tests (same patients, McNemar for
sens/spec, DeLong for AUCs); report incremental value over existing workup, not standalone accuracy.
- Validate. Independent population, preferably different setting/spectrum; report
calibration as well as discrimination.
- Report STARD. Flow diagram, indeterminate results handling, adverse events from testing,
and the exact cutoff with its derivation.
Example (R sketch):
Common pitfalls
- Case-control designs with healthy controls (spectrum bias inflating accuracy).
- Cutoff chosen on the same data used to report accuracy (optimism bias).
- PPV reported at study prevalence instead of clinical prevalence.
- AUC worship — ignoring the clinically relevant region of the ROC curve.
- Partial verification bias (reference test only for index-positives).
- Index test incorporated into the reference standard.
- Indeterminate/uninterpretable results silently dropped from the 2×2.
Security
- Security scanPassed, 90 of 100Pattern checks on the skill's files.
- Model reviewPassed
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/diagnostic-test-accuracy/SKILL.md
Popularity
- 7-day trend score
- 5
Not refreshed yet.
Extension points
pluginCustom plugin integration
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/aicodedecode/awesome-muse-skills/diagnostic-test-accuracy)