dromlakhani/md2skill/endo-cgm-vs-smbg-t1d-mdi
Claude Code and agent skill by dromlakhani/md2skill
- community
Checking that the SKILL.md file is still in the repository.
Recommends using continuous glucose monitoring instead of fingerstick self-monitoring for type 1 diabetes patients on multiple daily injections to reduce hypoglycemia risk. Use when a clinician evaluates glucose monitoring options for T1D on MDIs or manages hypoglycemia-prone T1D patients.
Install
npx vskill@latest install dromlakhani/md2skill/endo-cgm-vs-smbg-t1d-mdiSKILL.md
The same SKILL.md was published earlier as dromlakhani/md2skill/endo-cgm-vs-smbg-t1d-mdi.
Continuous Glucose Monitoring vs Self-Monitoring of Blood Glucose for Type 1 Diabetes on Multiple Daily Injections
STEP 1 — Gather Information
Confirm diagnosis of type 1 diabetes, current insulin regimen (multiple daily injections), history of hypoglycemia or hypoglycemia unawareness, patient’s ability to use CGM device, access to supplies, and interest in real-time glucose data.
STEP 2 — Rule In / Rule Out
Rule in: Patient has T1D and is using MDIs. Rule out: Patient is not on MDIs (e.g., using insulin pump) or does not have T1D; if ruled out, consider alternative monitoring strategies per other guidelines.
STEP 3 — Classify or Stratify
Stratify by hypoglycemia risk: higher priority for CGM in patients with hypoglycemia unawareness, frequent nocturnal hypoglycemia, fear of hypoglycemia, or impaired awareness of hypoglycemia (IAH); lower priority but still recommended for all T1D on MDIs.
STEP 4 — Decide
Recommend initiating real-time CGM rather than SMBG by fingerstick; provide comprehensive CGM education and ensure continued access to SMBG for sensor validation, warm‑up periods, and symptom‑glucose mismatches.
Clinical Guardrails / Mimics / Pitfalls
Do not rely solely on CGM without SMBG backup; do not skip patient education on device use and troubleshooting; avoid CGM use if patient cannot afford supplies or has uncontrolled skin irritation from adhesives; remember that SMBG remains necessary for calibration/validation and during sensor warm‑up.
Concrete Clinical Example
A 22‑year‑old college student with T1D on MDI reports twice‑weekly nocturnal hypoglycemia and fear of sleeping; after CGM initiation with structured education, hypoglycemia episodes drop from 8 per month to 2, and SMBG is used twice daily to verify sensor accuracy.
Source: Management of Individuals With Diabetes at High Risk for Hypoglycemia: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2023, https://doi.org/10.1210/clinem/dgac596
Security
- Security scanPassed, 90 of 100Pattern checks on the skill's files.
- Model reviewPassed
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/endocrinology/diabetes-technology/endo-cgm-vs-smbg-t1d-mdi/SKILL.md
Popularity
- Repository stars
- 12
- Repository forks
- 1
- 7-day trend score
- 18
Stars and forks are for the whole GitHub repository, not this skill alone. Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/dromlakhani/md2skill/endo-cgm-vs-smbg-t1d-mdi)