felixkarevo/construction-skills/construction-detailing
Claude Code and agent skill by felixkarevo/construction-skills
- community
Checking that the SKILL.md file is still in the repository.
Baukonstruktionsdetails — the joint- and layer-grammar that connects every building system into continuous build-ups (Schichtaufbauten). Layer logic: Trag-, Dämm-, Dicht-, Schutz- and Nutzungsschichten; Schale vs Schicht; ordering rules (vapour control warm-inside / weather tight outside, insulation always outside the load-bearing shell, capillary breaks, staggered layer joints / Entflechtung); multi-stage vs single-stage sealing (Stufigkeit). Connection grammar: Form-/Stoff-/Kraftschluss per d…
Install
npx vskill@latest install felixkarevo/construction-skills/construction-detailingSKILL.md
The same SKILL.md was published earlier as felixkarevo/construction-skills/construction-detailing.
Construction Detailing — Build-Up Logic and Junction Grammar (DACH)
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
A building does not leak, freeze or go quiet "in general" — it fails at a specific line where two planes meet, and it succeeds only if every functional layer survives that line. This skill is the connective tissue of the library: the other skills each own a system (roofs, windows, masonry, concrete, structure, physics); this one owns the junctions between them — the 300–1000 mm zone where the wall build-up must hand its vapour control, airtightness, thermal continuity, rain staging and acoustic mass over to the roof, the window, the plinth, the screed or a pipe — without breaking a single function.
Detailing here follows the DACH (German/Austrian/Swiss) construction culture: layered build-ups, modular coordination, DIN/DIN EN norms and trade rules, executed against tolerances (DIN 18202/18203). The physics is universal; the numbers are DACH-practice numbers.
Use this skill before drawing any junction, before freezing a wall build-up in the model, and whenever a review question is "but is the layer continuous there?"
Reality Check — Liability and Approval
This skill produces design aids, detailing logic and coordination checklists — not a stamped execution plan.
- Detailing in the German sense is HOAI service phase 5 (Ausführungsplanung) work: every drawn
junction here is a proposal to be verified by the responsible designer/architect against the current norm edition, the product approvals (allgemeines bauaufsichtliches Prüfzeugnis / ETA where applicable) and the manufacturer system guidelines it belongs to.
- Structural consequences of joints (ring anchor continuity, bearing lengths, waterstop design
pressures, movement force take-down) belong to the structural designer; see structural-systems and concrete-detailing.
- Waterproofing layer counts, upstand heights and pressure classes must be confirmed against
the current DIN 18531–18535 series (the legacy DIN 18195 scheme survives only in habit); airtightness numbers against current DIN 4108-7/GEG practice; tolerance tables against the current DIN 18202/18203 issues. [VERIFY before quoting a clause or table value in a submittal.]
- Products marked here with a rule of thumb (sealant joint depth ratios, mounting levels,
screed field sizes, upstand minimums) are principle-level guidance; the binding values are the manufacturer's system data sheet and the applicable norm at the project's contract date.
- When a junction is safety-relevant (fire compartment wall penetrations, guard rail anchorages
into waterproofing, balcony overturning), never resolve it by copying a catalogue detail — write the performance requirement and have the specialist detail it.
- If the user intends to build or price from an output of this skill, state plainly: this is a
planning model; licensed sign-off and the building-authority process are required first.
Section 0: Scope — and Which Sibling Skill Owns What
Detailing touches everything; to avoid duplicate and contradictory guidance, this library divides the territory:
| Territory | Owner | What THIS skill adds | |
|---|---|---|---|
| Roof layers, drainage classes, waterproofing stacks, upstands | roofing-waterproofing | How the roof stack terminates into wall/parapet/window-opening and how its layers continue at the junction | |
| Window/door units, lintels, sills, the Dichtungsstufen system | openings-windows-doors | Junction-zone build-up: mounting depth, insulation-plane continuity, reveal flanks, tolerance gaps around the fixed unit | |
| Masonry units, fmk design, bonds, ring beams, plinth/DPC | masonry-construction | Layer continuity across masonry-to-other-systems lines; movement-joint layout | |
| Rebar, cover, WU design, waterstops numerics | concrete-detailing | Where joints sit, why (buildability/movement), and what the sealing layer must survive | |
| U-values, Ψ, fRsi, Glaser, airtightness numbers | building-physics-thermal-moisture | The constructive measures that produce the assumed Ψ/n50 — geometry, layer stops, tapes, overlap directions | |
| Rw/L'n,w design, flanking classes | building-acoustics | The joint geometry (bearing + decoupling + flank sealing) that makes the acoustic model true at walls/floors | |
| Statical systems, bracing, load paths | structural-systems | Connection technology at element level (Schlussarten, bearings, tension chords) and its detailing consequences | |
| FreeCAD BIM hierarchy, void cuts, FEM | construction-freecad-bim | Layer-object modelling convention + IFC property propagation for build-ups |
If a task is inside one system, route to its skill. If it is a line where two systems meet, this skill leads.
Section 1: The Grammar of Build-Ups (Schichtaufbau)
1.1 What a detail must satisfy simultaneously (function hierarchy)
Every building element serves three main functions — Tragen (load-bearing), Einhüllen (enclosing), Ver-/Entsorgen (media supply) — and the envelope carries seven named sub-functions (bauliche Teilfunktionen) that a single junction must all survive:
- Feuchteschutz — moisture protection (rain, driven rain, splash-back, ground moisture,
pressing water, capillary moisture, vapour, condensate, ice/snow/wind-blown snow — each has its own control path)
- Wärmeschutz — thermal (continuous insulation plane, no bridge paths, surface
temperatures above mould limit)
- Luft-/Winddichtheit — air/wind tightness (continuous surface, mechanically protected)
- Schallschutz — acoustic (mass continuity or clean double-leaf, no rigid flanks)
- Brandschutz — fire (load-bearing duration + Raumabschluss; joints as weak as the element)
- Dauerhaftigkeit — durability (cross-cutting: drainage of water, protection of layers from
UV, frost, mechanical attack, erosion)
- Kraftleiten — force transmission (support forces, tie forces, anchor pulls through or
around the build-up without destroying 1–5)
The designer's conflict table, stated once and true everywhere:
- **Load-bearing wants dense/stiff material = thermally conductive; insulation wants porous =
carries nothing, is vapour-open, water-sensitive and acoustically poor.** Both compete for the same thickness. Resolve by (a) strict plane separation (insulation in its own layer, outside the structure) or (b) a compromise material (masonry with pores; wood, λ ≈ 0.15 W/(m·K), the only structural material that nearly does both — still not Passivhaus-grade alone).
- Water destroys insulation instantly: λ_water 0.6 vs λ_air 0.025 (≈ 24×) — a wet mat has lost
its function; a material that is perfectly watertight and vapour-open does not exist (no "Gore-Tex principle" in building sheets). Every build-up is therefore a strategy about which of the two the outer skin plays.
- Cracks = loss of tightness function: cracking is material-immanent in concrete/masonry and
mostly harmless for load, but must be controlled in sealing layers and at joints.
Terminology discipline (use these consistently in drawings and BIM labels):
- Schale (shell) = a layer with enough strength/stiffness to carry load (masonry wythe,
concrete wall, cladding panel acting as shell).
- Schicht (layer) = any material position with an assigned function regardless of stiffness
(a vapour foil is a Schicht, never a Schale).
- Aufbau (build-up) = the sequence of functional layers stacked in the thickness. Colloquially
"Dämm-Aufbau" = a layer package containing thermal insulation, not mere render/coating.
- Every layer sits at a fixed position because the gradients across the thickness —
temperature, vapour pressure, sound level, saturation — are directional. Moving a layer changes its function.
1.2 The five layer roles (functional classification of every position)
Read every build-up as five functional roles, however many physical sheets it contains:
| Role (German) | Function | Typical members | Failure if missing | |
|---|---|---|---|---|
| Tragschicht (structural layer) | Kraftleiten, fire mass | RC, masonry wythe, timber frame/CLT, steel deck | collapse, buckling of build-up | |
| Dämmschicht (insulation layer) | Wärmeschutz, acoustic spring | EPS/XPS/PIR, mineral wool, foam glass, cell glass | high Ψ/U, cold inner surfaces, single-leaf acoustic | |
| Dicht-/Steuerungsschicht (air/barrier layer) | Luftdichtheit + vapour control | Dampfbremse/-sperre foils, taped boards, airtight plaster, WU concrete itself | convective moisture damage, drafts, noise leakage | |
| Schutz-/Wetterseite (weather layer(s)) | Feuchteschutz + durability | render/ETICS skin, cladding + substructure, roof covering, tanking sheet, protection/filt layers | wetting, UV, frost, erosion, mechanical damage | |
| Nutzungsschicht (finish/wearing layer) | use + room physics | floor finish, screed, tiles, plaster, panelling, paving | abrasion, splash, cleanability, appearance |
Ordering rules (the laws of layer sequence):
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/construction-detailing/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/felixkarevo/construction-skills/construction-detailing)