Bauen im Bestand (working with existing structures) for DACH practice: condition assessment workflow (Dokumentation, Bestandsaufnahme, Voruntersuchung, Bauwerksprüfung with DIN 1076 cycles — Hauptprüfung 6 a / einfache Prüfung 3 a / Beobachtung, S/D/V Zustandsnote 0–4, RÜV and VDI 6200 CC/RC inspection cadence); material testing (reinforcement induction scan, half-cell potential, phenolphthalein carbonation, chloride profiles, Rebound ≥9 readings, cores per DIN EN 12504/13791 with 5%-fractile s…
Install
npx vskill@latest install felixkarevo/construction-skills/existing-structures-retrofitSemi-extensibleMentions customization, but needs skill-specific knowledge. Read the extensible skills standard
SKILL.md
The same SKILL.md was published earlier as felixkarevo/construction-skills/existing-structures-retrofit.
Existing Structures & Retrofit (Bauen im Bestand) — DACH Practice Skill
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
Agent-neutral procedure skill for assessing, re-checking and strengthening existing buildings (and for deciding whether to), under the German-language regulatory and normative framework. German terms are kept in parentheses because inventories, Prüfberichte and submissions circulate in German.
Scope. Reinforced concrete / masonry stock of the 20th century is the core (worked examples follow it); timber and steel defect logic is included at assessment level. Bridges/civil works appear only through the inspection machinery (DIN 1076) that building practice borrows. Energy and services retrofit is covered to the interface where the building-physics, TGA and fire skills take over.
0. How to use this skill — and the [VERIFY] convention
Use this skill when the task involves ANY of:
- converting/intensifying use of an existing building (living→office, add-on storey, new
openings),
- re-checking (Nachrechnung / Nachweis im Bestand) old members against current rules,
- planning strengthening (Aufbeton, jackets, CFRP, added walls, underpinning),
- diagnosing defects (cracks, spalling, corrosion, damp, mould, settlement),
- condition survey programmes and inspection cycles for owned/municipal stock,
- deciding retrofit vs. demolish, with whole-life numbers,
- modelling existing fabric (scan-to-BIM) for any of the above.
[VERIFY] convention. This skill is distilled from standards-adjacent references; some source tables arrived lossy. Any figure or rule marked [VERIFY] must be re-read in the current norm text (DIN EN 1990/1992, DIN 1045-2, DIN 1076, VDI 6200, GEG in force at project date) before it goes into a calculation report. Unmarked values are safe to use as planning figures; final design remains the job of a licensed Tragwerksplaner, and re-checks in Germany are coordinated with the Prüfingenieur für Standsicherheit / building authority early.
Hard limits of this skill: it never replaces a Voruntersuchung by qualified persons, never certifies Standsicherheit, and treats pollutant findings as triggers for specialist measurement (Schadstoffkataster), not as clearance.
1. Master sequence: assess → define target → verify → strengthen → monitor
Every Bestand project runs the same five phases; skipping or overlapping them is the root cause of most retrofit failures.
| Phase | German | Output | Typical trap | |
|---|---|---|---|---|
| 1 Assess | Bestandsaufnahme / Voruntersuchung | documented condition + material data + defects + pollutants | building on drawings alone; no cores; no crack mapping | |
| 2 Target | Zieldefinition / Nutzungsänderung | load model, target utilization, residual life, service class | authority/owner expectations not fixed before measuring | |
| 3 Verify | Nachrechnung / Bewertung | utilisation per member, code path (Bestandsschutz vs. new rules) | mixing code generations; ignoring old detailing rules | |
| 4 Strengthen | Ertüchtigung / Instandsetzung | method choice with force-transfer details, staging checks | composite-interface shear forgotten; load-introduction zones | |
| 5 Monitor | Beobachtung / Bauwerksbuch update | gauges, re-inspection cadence, documented as-built change | "repaired and forgotten"; no follow-up cycle |
Stock context that makes this discipline worth it: roughly 10 % of dwellings are younger than 15 a, about 60 % were built before 1960, and of refurbishments only ~25 % are driven by repair need while ~75 % are driven by change of use (Nutzungsänderung). A re-check that cannot prove the existing member under the NEW use will end in strengthening — plan for it.
Vocabulary (DIN EN 1990 / industry usage, keep them apart in reports):
- Instandhaltung — maintenance: preserves the target state (inspect, service).
- Instandsetzung — repair: restores the target state after damage (same design
goals).
- Ertüchtigung — upgrade: raises the target state above the original (new loads,
new code level, strengthening).
- Nachrechnung — re-check: proof of an existing structure under CURRENT rules,
with code-permitted relaxations where the standard allows.
- Bestandsschutz — grandfathering: lawfully-erected fabric may remain even if
today's rules differ (§ 2).
- Nutzungsdauer / Lebensdauer — design working life (DIN EN 1990: 50 a for
buildings, 100 a for monumental/bridge-type structures) vs. actual service life.
- Mischungsverbot — do not mix code sets within one verification; exception:
non-monolithic precast joints transmitting only support forces.
2. Code path: Bestandsschutz, change of use, and the Nachrechnung transition
2.1 Bestandsschutz (grandfathering) — what survives and what breaks it
Principle: a structure lawfully erected and maintained under the rules of its time may remain, even though it would not be approved today. Repairs may follow the old rules. Preconditions, all three:
- original lawfulness (Baugenehmigung, conformity at erection),
- no substantial change (keine wesentliche Änderung),
- condition as intended at erection — normal wear only.
Bestandsschutz is lost where there is danger to life/health, or where the intervention reaches the quality of a new building. Loss also never covers damage that arose from a rule now known to be insufficient (example in the case law tradition: overhead single-pane glazing ESG→VSG must be upgraded even on repair).
Authority levers (MBO logic, adopted into Landesbauordnungen):
- Anpassungsverlangen (§85(1)5 MBO) — authority may demand compliance to
current requirements where a concrete danger exists; burden of proof on the authority. Health-hazardous products (e.g. asbestos in reachable condition) can trigger replacement even of untouched parts.
- Harmonisierungsverlangen — on a substantial change, directly adjacent
constructive-related parts may be pulled up to current rules if no unreasonable extra cost results (e.g. a new stair may pull the adjacent landing and stair enclosure up to current rules).
- Intervention grading (stages A–C): A = renewal of defective parts with same
use, substance not destroyed → procedure-free; C = interventions so deep that a whole-building proof is triggered. Classify the planned work early.
2.2 Change-of-use / alteration rules that drive the statics
- Durchbrüche (new openings): local compensation per CURRENT rules (e.g. RC
frame action); no whole-building current-rule proof triggered by the opening.
- Umbau storey loads: load path of NEW or altered elements per current code;
existing parts may keep the historic verification and merely carry the added loads; any strengthening member is designed to the new code.
- Aufstockung (add-on storey): the added loads per current actions standard
must be carried; unchanged lower parts are proven under the ORIGINAL code including the new loads; if lower storeys would need substantial change anyway, the whole building is treated as a new build.
- Later "neue Erkenntnisse" (corrected old rules) can reopen the historic proof.
- New products (retrofit adhesives, FRP, grouts) always need current conformity
route (CE / abZ / ZiE) — grandfathering never covers them.
2.3 Nachrechnung: existing-code → EC2/DIN EN 1992 transition
Two-stage material assessment is the standard route: (1) derive nominal strengths from documents/historic code tables, (2) upgrade by testing where needed. The transition vocabulary old↔new must be exact in the report:
- σ-Verfahren (working stress) until 1972 in West Germany; **Traglastverfahren
(ultimate load)** introduced in the GDR from 1955 with a global η factor — GDR-era calculations are NOT directly comparable to EC2 utilization.
- 1972 DIN 1045: strength classes Bn50–Bn550 as 5 % fractile 28 d cylinder, design
value = β·Nennwert with global safety η; 1978 units switched N/mm²; 2001/2011 C-classes (EN 206).
- Concrete and steel partial factors may be reduced for the re-check of
existing RC if a qualified inventory exists (§ 4.7 modified γ table and its preconditions). Without qualified inventory, full current factors apply and the tabular historic strengths (§ 4.5) govern.
3. Documentation and survey programme (Bestandsaufnahme)
3.1 Paper/digital records to chase before any drilling
Checklist (as-found documentation set):
- ownership + land survey (Lageplan), permits (Baugenehmigung incl. old annexes),
- as-built statics: structural calculations, reinforcement plans/Barroschauen,
formwork plans, precast connection drawings,
- TGA as-builts, facade/waterproofing documentation, expert reports, test fields,
- utility routes and Kampfmittel (UXO) records, maintenance logs / Bauwerksbuch,
- records of changed actions: groundwater level shifts, adjacent excavations,
- events: fire, storm, flood, mining subsidence, earthquakes,
- alteration history (changes of use, added loads: racks, machines, PV, greening),
- neighbour situation (Beweissicherung — documented adjacent-condition).
Missing records are the normal case for pre-1960 fabric and force the testing route of § 4. The documentation set closes with a Bauwerksbuch-style conformity summary.
3.2 Physical survey methods (selection by question)
| Question | Method | Notes from practice | |
|---|---|---|---|
| rebar position/diameter/cover | induction scanning / cover meter | destructive confirmation on anchorage zones | |
| carbonation depth | phenolphthalein on fresh fracture | uncarbonated = red; carbonated stays colourless below pH≈9 | |
| chloride content | powder from ground profiles, wet chemistry / potentiometric titration | profile vs. depth, not single surface value | |
| corrosion activity | half-cell potential mapping | indications, not quantification | |
| concrete strength | Rebound (Schmidt) and/or cores | Rebound supplementary only; cores per § 4.6 | |
| crack width | calibrated loupe / gauge | map plan + elevation, mark active-crack monitors | |
| crack depth | core or ultrasonic across crack | ||
| voids/laminations masonry | tap test; endoscopy | ||
| moisture | resistance/capacitive probe, CM method, oven-dry weight | ||
| structure/moisture in depth | ultrasonic, seismic, radar, IR-thermography | ||
| masonry strength | unit cores + mortar joint strength; wallette (lab) | tap/scratch + rebound as preselection | |
| timber | resistograph (bore resistance), glue-area lab tests, moisture, fastener corrosion (destructive), pest expert | ||
| steel member | coupons for composition/strength, weldability check, coating thickness (ultrasonic), lead/asbestos in old coatings |
Site works order: photographic documentation → survey/control points → crack mapping incl. gauges on the building AND at neighbours → function checks of equipment → geometric control checks (dimensions, axes, storey heights vs. drawings) → actual use loads / occupancy audit → maintenance-state audit.
3.3 Pollutants (Schadstoffe) — periods to trigger testing
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/existing-structures-retrofit/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Extension points
pluginCustom plugin integration
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/felixkarevo/construction-skills/existing-structures-retrofit)