Statics and load-bearing verification workflow (Baustatik / Nachweisführung) for DACH/Eurocode practice: actions EN 1991 (dead load with digested unit weights, imposed loads by category A–E/T/Z, snow zones with altitude formulas, wind zones and exposure with digested qp/cpe values, temperature, snow drift and slip, maintenance loads), combinations EN 1990 (ULS γG 1.35/1.0, γQ 1.5, full ψ0/ψ1/ψ2 table, EQU 1.1/0.9, SLS characteristic/frequent/quasi-permanent, accidental and fire noted), equivale…
Install
npx vskill@latest install felixkarevo/construction-skills/structural-analysisSemi-extensibleMentions customization, but needs skill-specific knowledge. Read the extensible skills standard
SKILL.md
The same SKILL.md was published earlier as felixkarevo/construction-skills/structural-analysis.
Structural Analysis — Load-Bearing Verification Workflow (DACH / Eurocode practice)
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
1. Purpose, scope, and siblings
This skill covers the verification chain for building structures: idealization → actions → combinations → internal forces → ULS (GZT, Grenzzustand der Tragfähigkeit) → SLS (GZG, Gebrauchstauglichkeit) → detailing checks → documentation. It is a design-assistant skill: it tells the agent which checks to run, in what order, with which digested values, and how a correct worked solution looks numerically.
Load-bearing topics that belong to sibling skills (cross-referenced, not duplicated):
| Topic | Sibling skill | |
|---|---|---|
| Choosing the structural system, statical determination, bracing concept at scheme level | structural-systems | |
| Bar-lift-bar schedules, anchorage/lap detailing drawings, congestion | concrete-detailing | |
| Masonry wall design (EC6 simplified method, concentric compression, wall coupling) | masonry-construction | |
| Full timber/steel member and connection design (EC5/EC3) beyond verification checks here | timber-steel-design | |
| Full geotechnical design (EC7/DIN 1054/4017/4019, piles, excavations) | geotechnics-foundations | |
| Seismic actions and ductile detailing (EC8 / DIN 4149 legacy) | seismic-design | |
| Compartmentation, fire-resistance classes, tabulated fire members | fire-protection-building |
Language convention: English text, German terms in parentheses for site- and norm-matching.
2. Reality check — limits of agent-performed analysis
- The agent may build model idealizations (statical systems, load assumptions, combination
logic) and run/interpret checks, but in the German/European system the load-bearing verification (Standsicherheitsnachweis) of a project requires a licensed/prüfbarer engineer (Tragwerksverfasser; bauphysically responsible planer) whose calculation is signable and inspectable. Agent output is a draft/companion, never a substitute.
- Software output must be plausibilized (Plausibilitätskontrolle). Mandatory plausibility actions
from mechanics practice: visualized deformation check, zero-stress test for rigid-body motion (spannungsfreie Verformung), patch tests, benchmark cases, mesh convergence study, and at least one independent hand calculation per load case / per governing member. A model that fails to converge on sound geometry should raise doubt on the element, not silent trust.
- In several German Bundesländer a type-reviewed statics check (Prüfstatik / Typostatik) by a
Prüfingenieur is or was part of the approval process for standardized structures; check and combination rules (Kombinationsregeln) are exactly what gets reviewed. VERIFY current state per Bundesland — this skill digests no procedural law.
- Reliability background (for sanity of the factors): partial-factor format is a calibration of
target reliability indices; ULS target β = 3.8 (normal effort, 50-year reference), SLS β = 1.5 (DIN 1055-100 / EN 1990 logic as digested). Resistance γM and action γF tables in §5 reflect the digested NA editions — dated NA values must be re-verified against the current NA before use.
- All numeric values below are reproduced from worked-example digests; fragments flagged
[VERIFY] were garbled in extraction or edition-dated and must not be used as sole authority.
3. Evidence tiers
- T1 — Normative (recognized rules of technique / anerkannte Regeln der Technik):
DIN EN 1990 (Basis), 1991-1-1…-1-6 (actions), 1992-1-1 ( concrete), 1993-1-1 (steel), 1995-1-1 (timber), 1996-1-1/-3 (masonry), 1997-1 (geotech), each with its National Annex (NA), plus DAfStb-Richtlinie WU (waterproof concrete), DIN 4109/4108 (where structural relevance). NA values change with editions (e.g., steel γM1, CRd,c for shear) — current NA governs.
- T2 — Handbook tables and derived design aids: design-value tables (fcd, fyd, fbd, lb,rqd,
As-tables, ρw,min), continuous-beam coefficient tables, two-way-slab coefficient tables of the Pieper/Martens family, interaction diagrams (BT-type column charts), χ-buckling-curve parameters, DIN 1054 allowable base-pressure tables, DIN 4017 bearing-capacity factors, DIN 4085 earth-pressure coefficients. Reliable, but check the edition the table was built for.
- T3 — Empirical span/depth heuristics (from structural conception literature): slab one-way
d ≈ l/30…l/25, economical solid-slab limit ~8 m (t ≈ 300 mm), flat slab practical limit ~7 m bay, beam h ≈ l/10 (d = l/8…l/12), timber joist spans ≤ ~5 m, ring beam span ≤ 30·t, bracing-wall thickness ≥ 1/3 of braced wall and ≥ 115 mm, bracing-wall effective length ≥ h/5 — usable for pre-dimensioning, always confirmed by checks.
- T4 — Rules of thumb without digested pedigree: [VERIFY] — e.g. "assume h = l/20 for
two-span RC beams", "office girder l/12", wind force reduction for flexible buildings, "1.5 % of vertical load as horizontal force for floor diaphragms". Use for concept only.
4. Load model (actions per EN 1991, digested German values)
4.1 Permanent actions — unit weights [kN/m³ unless noted]
| Material | γ | |
|---|---|---|
| Reinforced concrete (Stahlbeton) | 25.0 | |
| Normal concrete (Normalbeton) | 24.0 | |
| Heavy concrete (Schwerbeton) | 28.0 | |
| Lightweight concrete, RDK 1.0–2.0 | 9.0–20.0 (+1 fresh/RC) | |
| Cement mortar (Zementmörtel) | 19–23 | |
| Lime-cement mortar (Kalkzementmörtel) | 18–20 | |
| Gypsum mortar | 12–18 | |
| Masonry units by dry density class RDK: ≤1.4 → ~16; 1.6–1.8 → 18; 1.81–2.0 → 20; 2.21–2.4 → 24; 2.41–2.6 → 26 (RDK ≤ 1.4 light/thin-joint −1) | 0.31–0.35 → 5.5 … 0.91–1.0 → 12 … 2.41–2.6 → 26 (linear per class) | |
| AAC unreinforced plates (DIN 4166): RDK 0.35→4.5 … 0.80→9.0 (−0.5 thin-joint) | 4.5–9.0 | |
| Reinforced AAC panels (DIN 4223): 0.40→5.2 … 0.80→9.5 | 5.2–9.5 | |
| Plaster [kN/m² per 20 mm unless noted]: gypsum 15 mm 0.18; lime/lime-gypsum/gypsum-sand 20 mm 0.35; lime-cement 20 mm 0.40; cement mortar 20 mm 0.42 (30 mm 0.80); lightweight mortar 20 mm 0.30 | 0.18–0.80 | |
| Screed [kN/m² per cm]: cement 0.22; CaS 0.22; mastic asphalt 0.23; industrial 0.24; gypsum 0.20 | 0.20–0.24 | |
| Roof covering [kN/m² incl. battens, excl. rafters]: concrete/concrete-clay tile ≤10 pcs/m² 0.50–0.55; deep profile 0.60–0.65; flat interlocking 0.55; monk/nun mortar-fixed 0.90; bitumen shingle 0.25; fibre-cement short-wave 0.24/wave 0.20; metal profile 0.05–0.35; reed/thatch 0.70 | 0.05–0.95 | |
| Sealing layers: welded bitumen sheet 0.07; loose DIN 52130/32 0.04 (0.07 bonded); plastic sheet 1.5 mm 0.02; gravel 5 cm ≈ 1.0 kN/m² | — | |
| Timber: C24 4.2; C30 4.6; D30 oak 6.4; GL24h 3.7; GL28h 4.0; GL32h 4.2; plywood softwood 5.0; chipboard 7–8; cement-bonded 12.0 | 3.5–12 | |
| Steel | 77–78.5 | |
| Aluminium | 27–28 | |
| Glass | 25 | |
| Water | 10 | |
| Backfill (compacted sand/gravel Schüttung) | 15–20; angle of repose ~35° | |
| Snow, shape-factor/drift formulas (μ3 valley cap, μW wind-drift cap, §4.3) | 2.0 | |
| Snow, eave-overhang formula only (§4.3) | 3.0 (denser/wetter snow specifically causes eave overhang — not a conflicting value, a different formula) |
Fresh/reinforced lightweight concrete: +1.0. Rule from worked examples: RC slab self weight = thickness·25 (e.g. 0.20 m → 5.0 kN/m²; 0.22 m → 5.5 kN/m²).
Note: DIN EN 1991-1-1/NA Annex A does not cover steel trapezoidal-deck or green-roof (Dachbegrünung) self-weights — use manufacturer data and the FLL Dachbegrünungsrichtlinie (2008) respectively (Lastannahmen – Beispiele, Ch.3 §3.1). Stair-flight self-weight is computed per horizontal projected (Grundfläche) area, same reference area as the imposed load, so it superposes directly with qk; steps are a half-triangular add-on over the sloped RC waist slab (ibid., Ch.3, worked Example 3.9).
4.2 Imposed loads, buildings (DIN EN 1991-1-1/NA, characteristic)
qk [kN/m²] on area / Qk [kN] concentrated on 50×50 mm:
| Cat. | Use | qk | Qk | |
|---|---|---|---|---|
| A1 | pitched-roof space ≤ 1.8 m | 1.0 | 1.0 | |
| A2 | living rooms with load distribution | 1.5 | – | |
| A3 | living rooms without distribution | 2.0 | 1.0 | |
| B1 | offices, corridors, practices, no heavy equip. | 2.0 | 2.0 | |
| B2 | hospital/corridors, kitchens, cellars | 3.0 | 3.0 | |
| B3 | B1/B2 with heavy equipment | 5.0 | 4.0 | |
| C1 | table areas (schools, cafés, receptions) | 3.0 | 4.0 | |
| C2 | fixed seating (churches, theatres) | 4.0 | 4.0 | |
| C3 | freely accessible (museums, lobbies) | 5.0 | 4.0 | |
| C4 | sports stages, stages | 5.0 | 7.0 | |
| C5 | large gatherings (concert halls, fixed stands) | 5.0 | 4.0 | |
| C6 | regular huge crowds, loose stands | 7.5 | 10.0 | |
| D1 | retail ≤ 50 m² | 2.0 | 2.0 | |
| D2 | retail / department stores | 5.0 | 4.0 | |
| D3 | D2 with tall shelving | 5.0 | 7.0 | |
| E1.1 | light factories/workshops, cattle stalls | 5.0 | 4.0 | |
| E1.2 | general storage incl. libraries (minimum!) | 6.0 | 7.0 | |
| E2.1 | medium/heavy industry | 7.5 | 10.0 | |
| T1 | stairs dwelling/office | 3.0 | 2.0 | |
| T2 | other stairs | 5.0 | 2.0 | |
| T3 | stand access/escape stairs | 7.5 | 3.0 | |
| Z | balconies, roof terraces, loggias | 4.0 | 2.0 | |
| H | roofs, not normally accessible | 2.0 (area), 1.0 (single-person load); no superposition with snow | — |
Partitions (Trennwandzuschlag), DIN EN 1991-1-1 §6.3.1.2(8)/NA — confirmed formula: walls ≤ 3 kN/m run (incl. plaster) → Δqk ≥ 0.8 kN/m²; > 3–≤ 5 kN/m → Δqk ≥ 1.2 kN/m²; no add-on if qk ≥ 5.0 kN/m². Category A3 areas without adequate load-distribution to supporting members may reduce this by 0.5 kN/m². Digested worked examples use 1.0 kN/m² (assembly slab, above the 0.8 code floor) and 1.2 kN/m² (office 2.0 + 1.2 = 3.2; living 1.5 + 1.2).
Load reduction factors (do not combine the two with each other, and never combine either with ψ-reduction — use the single most favourable factor):
- Area reduction (secondary members: beams/columns/walls/foundations), tributary area A [m²]:
categories A/B/Z → αA = 0.5 + 10/A ≤ 1.0; categories C–E1.1 → αA = 0.7 + 10/A ≤ 1.0.
- Multi-storey reduction (vertical member carrying n > 2 storeys of the same use category):
categories A–D, Z → αn = 0.7 + 0.6/n; categories E1.1, E1.2, E2.1–E2.5, T → αn = 1.0 (no reduction — high/fixed-load categories don't benefit from storey averaging).
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/structural-analysis/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Extension points
pluginCustom plugin integration
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/felixkarevo/construction-skills/structural-analysis)