Lifecycle-based design and evaluation of buildings for DACH practice (Nachhaltiges Bauen): life-cycle thinking with Ökobilanz module model (A1–A3 manufacture, A4–A7 construction/installation, B1–B7 use, C1–C4 end-of-life, D benefits beyond boundary) per DIN EN 15978 / 15804+A2, EPDs and generic national/building-epic database data sources, recyclate-content and material-passport evidence; embodied-carbon factors per material with numeric ranges and a comparison table (concrete ~200 kg CO2e/m³ w…

Install

npx vskill@latest install felixkarevo/construction-skills/sustainable-construction

Semi-extensibleMentions customization, but needs skill-specific knowledge. Read the extensible skills standard

SKILL.md

The same SKILL.md was published earlier as felixkarevo/construction-skills/sustainable-construction.

Sustainable Construction (Nachhaltiges Bauen) — DACH Lifecycle Design

Simple-first gate (governs how this skill is applied). Default every choice here to
the simplest proven solution at the agreed standard tier — see the governing skill
simple-first-building (complexity ladder §1). Escalate to more demanding construction
(innovative systems, one-off details, higher comfort tiers) only when the client
explicitly asks for it, with cost/schedule impact stated; deviate below the usual
standard or the aarRdT only via the documented risk-acceptance machinery
(simple-first-building §3) — public permission never cures the private default.

Use this skill whenever the agent must judge or shape a design decision against sustainability: material substitution ("wood instead of concrete?"), insulation choice, heating-system choice, envelope standard, embodied-carbon estimates per m²BGF, certification orientation (DGNB/BNB/QNG), reuse/recycling questions, indoor-air and comfort limits, life-cycle cost comparisons, retrofit-vs-demolition verdicts, or customer claims that smell like greenwashing ("climate-neutral house", "CO₂-free concrete"). It is the cross-domain trade-off layer: it does not replace the structural, physics, services, or cost skills — it arbitrates between them and forces the reasoning to be disclosed.

Sibling skills (call them, do not duplicate their scope):

  • building-physics-thermal-moisture — U/R/Ψ proofs, Glaser, summer heat index, n50.
  • building-services-tga — heat load, HP/boiler/PV/RLT sizing detail, plant rooms, GEG/GModG component duties.
  • building-acoustics — DIN 4109/VDI 4100 mass and flanking proofs.
  • structural-systems, concrete-detailing, timber-steel-design, masonry-construction — load-bearing decisions.
  • building-materials — product-level properties λ/μ/ρ/fc.
  • cost-management-din276 — cost groups, estimates, rates.
  • fire-protection-building — GK classes, reaction classes, MVV TB constraints.
  • roofing-waterproofing, openings-windows-doors, construction-detailing — layer durability and joint rules.
  • building-regulations-permits — BauGB/LBO/MBO framing, permits.

Units convention: GWP in kg CO₂e (CO₂-equivalents, GWP100); material GWP density kg CO₂e/m³ and per mass kg CO₂e/t; building indicators kg CO₂e/m²BGF (DIN 277 gross floor area) or per net usable area; energy kWh/(m²·a); emission factors g CO₂e/kWh; prices €/t CO₂e. German terms in parentheses at first use. All numbers carry a tier tag (section 2); edition- and price-dependent numbers carry ⚠ VERIFY — treat them as planning-grade until re-read against current sources.

0. How to use this skill

  1. Identify which lifecycle question is actually asked: sufficiency (should this

exist?), embodied carbon, operational energy, resources/waste, health/comfort, cost over time, or certification. Route each to the relevant section.

  1. Decide before computing: state the system boundary (modules), the reference

period (DE: 50 a comparison frame, ⚠ ≠ real lifetime), the functional area (BGF/NRF/NGF), and the data tier. Never mix tiers in one number chain.

  1. Apply the sufficiency-first order of intervention (section 12.2): program

reduction → compact form → structure choice → envelope → systems → PV/renewables → offsets/credits last.

  1. Every recommendation must disclose the trade-off it pays for. A timber wall

that gives up fire/acoustic mass, a compact block that gives up units, a thick mineral insulation that gives up floor area — say so explicitly (section 12.4).

  1. Where the digested knowledge is silent (explicit gaps below), say "not in

knowledge base" instead of inventing: per-version DGNB criterion weights, exact U-value annexes beyond flagged ranges, current subsidy rates, radon guidance specifics, per-product EPD values.

Explicit gaps of the underlying digests — do not fabricate around them:

  • DGNB criteria weights/point tables per version (only families and levels known).
  • Heat-demand tables by construction-age band (only stock trajectory + HP-suitability by age exist).
  • Passivhaus component values beyond the ≤15 kWh/(m²a), n50 ≤ 0.6 anchors.
  • Full current GEG/GModG annex values (flag edition!).
  • Recycled-content certificate scheme mechanics (referenced generically only).

1. Reality check — what this skill can and cannot deliver

  1. Sustainability assessments produced here are planning aids (Ökobilanz-vorlagen,

Variantenvergleiche, Kennwert-Schätzungen), not certificates, not an eLCA/Level(s) submission, not a QNG proof. A formal building LCA must run in an accepted tool on EPD/database data with an accountable practitioner; a certificate requires an accredited body and auditor.

  1. Regulation is moving fast: EPBD recast (published 2024, national transposition due

~2 years), GEG→GModG renaming, CO₂ pricing ladder, subsidy programmes re-cut quarterly. Everything money- and law-related here is a snapshot ⚠ VERIFY against the text in force at project date.

  1. A "sustainable" verdict is always multi-criteria. If the agent optimises the one

metric it can compute best (usually kg CO₂e), it is wrong by construction. Section 12 prescribes the disclosure discipline.

  1. Embodied-carbon claims on products ("CO₂-neutral") are valid only for module A1–A3

unless the declaration states otherwise; biogenic storage can flip positive at end-of-life. Treat all single-number product claims with the pitfall list (section 15).

  1. Long service life is the strongest single lever ("lange Nutzungsdauer = beste

Bilanz"). Bestandserhalt/Umnutzung before Neubau is the default rule; demolition must overcome that presumption with data (LCC+LCA), not taste.

2. Evidentiary tiers (never mix tiers in one number chain)

TierStatusExamples (this skill)
T1Law / binding dutiesGEG reference-building duties, KrWG Art. 14(2) ≥70 % quota, EU taxonomy thresholds (≥90 %/≥70 %, SVHC/VOC limits as contract-relevant), EPBD dates once transposed, MindBauRL/MVV TB fire ceilings on insulation, BauGB §9 levers
T2Standards & calculation modelsDIN EN 15978/15643, EN 15804+A2 modules, ISO 14040/44, ISO 20887 (DfD), DIN 18940 (clay), DIN EN 197-1/-5 cements, DAfStb RC rules, DIN 4226-101, DIN EN 16757 (recarbonisation), GEG/DIN V 18599 method
T3Recognised practice / branch dataindustry EPDs and branch averages, national public building-ecology database, public lifecycle-calc tool for federal buildings (Bauteilkatalog), LESS steel label, DGNB-adjacent indices (UMI, ZI, PCDS/ISO 59040, DIN SPEC 91484), component service-life tables
T4Rules of thumb (plausibility only)"1 m³ wood ≈ 1 t CO₂ stored", "~200 kg CO₂e/m³ concrete", quick per-m²BGF carbon template (section 14), "operation ≈ 80 %+ of LCC", "retention beats replacement in most residential retrofits"

A T4 factor may start a conversation; it never closes a T1 duty or an offer with a CO₂ ceiling clause (section 11.5). If only T4 exists, say so in the output.

3. Lifecycle thinking: the framework

3.1 Where the number 2045 comes from and what buildings must do
  • Germany: climate neutrality 2045 (constitutional rank, KSG ladder: −65 % GHG by 2030,

−88 % by 2040, both vs 1990 ⚠ VERIFY current KSG target revision). EU: −55 % by 2030, climate-neutral buildings stock 2050 (EPBD trajectory).

  • Buildings contribute ≈ 40 % of German GHG across operation + building products; the

construction sector consumes ≈ 90 % of mineral raw materials and generates ≈ 55 % of national waste (DE); EU framing: ~50 % of raw materials, >35 % of waste, building-material GHG ≈ 5–12 % of national emissions with up to 80 % of that addressable by material efficiency (T3, order-of-magnitude).

  • Currently the use phase is still ~⅔ of building GHG; as the grid decarbonises,

embodied carbon moves to the dominant share — that is why early structural decisions now matter more than the last centimetre of insulation.

  • 80–90 % of the buildings in use in 2045 already exist today. Renovation rate must at

least double from ~0.7–1 %/a to ≥2 %/a ⚠ VERIFY (policy target drift).

3.2 The three-pair principle set

Three-pillar model (Ökologie, Soziales, Ökonomie, equal weight — Carlowitz 1713 lineage; "Nachhaltigkeit 4.0" adds economics-ethics + technology). Operationalised for construction as four implementation principles — use these four verbs in every recommendation:

  • Suffizienz (demand avoidance): smaller program, compact form, shared use, no

over-technologising. "Die Aufgabe hinterfragen."

  • Effizienz (less impact per unit): better U, better JAZ, less clinker, less steel.
  • Konsistenz (different, compatible systems): renewables instead of fossil,

recyclable/bio-based materials, separable constructions.

  • Resilienz (robust under changed conditions): adaptability, low-tech redundancy,

heat/flood/price-shock tolerance, simple operable systems.

Low-Trend principle (digest): minimise technical complexity — a reduced-complexity building is more resilient AND more operable under trade-labour scarcity; use physical effects (mass, orientation, buoyancy, shading) before machines. "Schlechte Konstruktion heilt keine Technik." Passive → semi-passive → active is also the mandated TGA ordering (section 6.5).

3.3 Cycle times and the phase-0 lever
LayerTypical cycle / service lifeDesign consequence
Structure (Tragkonstruktion)>50 a, often several × 50 (brick ~150 a stated technical life; concrete facades >50 a)decide for the century: material + durability + reserve
Envelope/Hülle40–60 a (WDVS 40–60, windows 40–50, seals/screws plan-mässig only 25 ⚠ → 2 cycles over 50 a, doubling A+B impacts)specify ≥50 a for fast-cycling parts or make them exchangeable
Services (TGA)~30 a (boiler ~20–25, HP ~15–20, chillers 20–25, pumps ~12 ⚠ VERIFY table collapsed in source)accessibility, simple interfaces, upgrade routes
Fit-out/Inneneinbau1–5 a short / 5–30 a medium cyclesseparability from structure
Planning horizonconventional assessment 50 a (DE comparison frame; CH 60 a)all LCA/LCC windows here unless told

Phase 0 (Projektentwicklung, before HOAI LPH 1) is the key phase: the client's five strategies (climate/financing, planning/procurement, use/operation, maintenance, recovery/re-use) and the quantified target (e.g. kg CO₂e/(m²·NRF·a) over life, energy standard, certification level) get fixed here. Design freeze from Projektstufe 2 (AHO Heft 9); later changes are a process loop, not an edit. Influenceability is highest at the start and the cost of change rises steeply — sustainability consulting that arrives in detail-design stage cannot move the structure, only the finishes.

3.4 The pricing frame (why carbon numbers matter commercially now)

This is the start of the file. Read the full SKILL.md on GitHub.

Security

  • Security scanPassed, 100 of 100Pattern checks on the skill's files.
  • Model reviewNot runA model review is scheduled for the next rescan.

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

7-day trend score
0

Not refreshed yet.

Extension points

  • pluginCustom plugin integration

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/felixkarevo/construction-skills/sustainable-construction/badge)](https://verified-skill.com/skills/felixkarevo/construction-skills/sustainable-construction)

Something wrong with this skill or its page? Tell us.