felixkarevo/construction-skills/timber-steel-design
Claude Code and agent skill by felixkarevo/construction-skills
- community
- ext:[{"type":"plugin","description":"Custom plugin integration"}]
Checking that the SKILL.md file is still in the repository.
Structural design of timber (Nadel- und Laubholz) and steel building systems to Eurocode 5 and Eurocode 3 for DACH practice: timber products and strength classes C14-C40 / D30-D70 / GL24h-GL36h plus CLT, LVL, duo/trio beams with fm,k / ft,0,k / fc,0,k / fv,k / E0,05 tables, kmod by load duration + service (use) class, kdef, gamma_M = 1.3 members / 1.1 simplified fastener check / reduced gamma_M,fi in fire; member design (bending incl. lateral-torsional buckling k_crit chain, axial buckling kc c…
Install
npx vskill@latest install felixkarevo/construction-skills/timber-steel-designSemi-extensibleMentions customization, but needs skill-specific knowledge. Read the extensible skills standard
SKILL.md
The same SKILL.md was published earlier as felixkarevo/construction-skills/timber-steel-design.
Timber & Steel Design for Buildings (EN 1995 / EN 1993, DACH practice)
Simple-first gate (governs how this skill is applied). Default every choice here tothe simplest proven solution at the agreed standard tier — see the governing skillsimple-first-building(complexity ladder §1). Escalate to more demanding construction(innovative systems, one-off details, higher comfort tiers) only when the clientexplicitly asks for it, with cost/schedule impact stated; deviate below the usualstandard or the aarRdT only via the documented risk-acceptance machinery(simple-first-building§3) — public permission never cures the private default.
This skill covers the design logic, code values and detailing rules for the two linear-material systems of European building construction: timber construction (Holzbau) to Eurocode 5 (DIN EN 1995-1-1 + National Annex) and steel construction (Stahlbau) to Eurocode 3 (DIN EN 1993-1-1 + National Annex), including the fire parts (EN 1995-1-2 / EN 1993-1-2) and the connection rules (EN 1993-1-8 / -1-5, EN 1995-1-1 §8 with fastener ETAs/abZ). It is the design-level companion to the framing-systems skill (which answers which system) and to building-materials (which answers what the product is).
In scope: material/design values, member verification chains, fastener and welded connection checks, stability (buckling / lateral-torsional buckling), serviceability (deflection, vibration), durability and use classes, structural fire design, practical framing systems with span/depth rules, worked calculation chains, FreeCAD/IFC modelling defaults.
Out of scope: whole-building action tables and combinations (→ a loads/structural-systems skill), seismic design (→ seismic-design), foundation design under column feet and hold-downs (→ geotechnics-foundations), execution and contract logic (→ construction-detailing), concrete and masonry design (→ concrete-detailing, masonry-construction).
Sibling skills
| Skill | Where this file hands off | |
|---|---|---|
| structural-systems | system choice at building level (massive vs timber vs steel) | |
| building-materials | product standards, densities, λ/μ data, CE/DoP status of sections & boards | |
| fire-protection-building | building classes GK1-GK5, required F/R durations, escape routes | |
| construction-detailing | joint geometry, water-shedding, layer sequences, tolerance strategy | |
| concrete-detailing | steel/timber-to-concrete interfaces: anchors, base plates, WCC topping | |
| seismic-design | horizontal actions, ductility, bracing system choice | |
| geotechnics-foundations | uplift and thrust into ground; column feet |
Reality check — read before using any number
- **This skill produces design aids and calculation guidance for planning,
pre-dimensioning and FreeCAD modelling ONLY.** Every span, section, bolt count, screw spacing and charring rate below is a preliminary sizing aid, a code minimum, a table excerpt, or a rule of thumb.
- **Any design intended for construction of a real occupied building must be
analysed, designed and signed by a qualified structural engineer (in Germany: Tragwerksplaner per Landesbauordnung, plus Prüfstatik where required; in Austria/Switzerland the locally licensed equivalent). This is *more* true for timber and steel than for massive construction: these systems are connection-governed, stability-governed and uplift-governed**. A missed hold-down, an unbraced compression flange or an under-designed bolt group is a collapse mechanism, not a crack.
- National Annex (NA) differences are the rule, not the exception. gamma_M
values, kmod wind rules, lateral-torsional buckling parameters, buckling curve assignments and deflection recommendations differ DE/AT/CH and move with every code edition. The digests behind this file reflect EC5 2010-12 + German NA 2013-08 (+ A2 2014) and EC3 + German NA, early-2020s handbook state — VERIFY the currently introduced edition per project.
- Values reconstructed from source digests carry a
VERIFYflag. Treat
the flags as binding. Several table columns were transposed or garbled during extraction (flagged where detected). Never quote a flagged number to a fabricator.
- **Never present model output, a span-table lookup or a calculation from this
file as construction-ready.** The correct framing is always "preliminary sizing and coordination geometry — requires design and signature by a qualified structural engineer". Say it unprompted when a user starts ordering steel, sending cutting lists to a timber workshop, or deleting a brace "because the model still stands".
- Never certify. No stamped drawing, no stability certificate, no
fabrication drawing presented as approved-for-construction.
- Loads are never assumed. Basic wind speed, snow zone, site elevation, use
category and (where relevant) seismic zone come from the current maps and the project brief. Lightweight structures are frequently uplift-governed rather than gravity-governed — the reverse of massive construction.
Evidence tiers
| Tier | Meaning | Examples here | Use | |
|---|---|---|---|---|
| T1 | EN + NA design value formulas and tables | fm,k, kmod, gamma_M, chi-curves, Fv,Rd | citable after edition check | |
| T2 | Product-standard geometry (EN 10365, EN 336, EN 14080, EN 16351) | profile nominal sizes, tolerances | spec-grade after lookup | |
| T3 | Handbook tables and worked-example digests | section property excerpts, Rk of nails, bolt capacities | guidance; flagged cells | |
| T4 | Rules of thumb | span/depth ratios, 1-2 % bracing force | massing only |
Section 1: Code basis — what governs what
1.1 Standards map
| Topic | Timber | Steel | |
|---|---|---|---|
| Basis / actions | DIN EN 1990, EN 1991-1-1…-1-6 + NAs | same | |
| Design (ULS/SLS) | DIN EN 1995-1-1 + NA | DIN EN 1993-1-1 + NA | |
| Fire | DIN EN 1995-1-2 + NA | DIN EN 1993-1-2 + NA | |
| Connections | EN 1995-1-1 §8 + fastener ETAs / abZ | EN 1993-1-8 (bolts, welds), EN 1993-1-5 §6 (web bearing/stiff panels) | |
| Plates / class 4 | EN 1995-1-1 §6.2 (cracked-section shear) | EN 1993-1-5 (effective widths, patch loading, shear buckling) | |
| Buckling / LTB | EN 1995-1-1 §6.3 | EN 1993-1-1 §6.3 | |
| Composite floors | wood–concrete (WCC) via ETA pin connectors | EN 1994-1-1 / -1-2 (head studs, trapezoidal sheet) | |
| Material products | EN 338 (strength classes), EN 336 (sizes & deviations), EN 408 (test/strength), DIN 4074-1 (visual/machine grading S7/S10/S13), EN 1194 + EN 14080 (BSH/glulam), EN 16351 (CLT/Brettsperrholz), EN 14374 (LVL), EN 15497 (finger-jointed solid), (duo/trio beams: Balkenschichtholz via EN 14080), EN 636 (plywood), EN 300 (OSB) | EN 10025 (hot-rolled grades S235…S700), EN 10210/-10219 (hollow sections), EN 10365 (nominal sizes & designation), EN 10218 (welded sections) | |
| Fasteners | EN 14592 (dowels, nails, screws, bolts — strength & stiffness), EN 10230-1 (nail dimensions), EN 14566 (ring & shear plate connectors), EN 14545 (screw-in inserts), ETAs for structural screws and glued-in rods | EN 15048 (fit bolts), EN 14399 (preloaded HRSG 8.8/10.9), ISO 4063 + ISO 2553 (weld process/symbols), EN 1090-2 (execution) | |
| Durability | DIN 68800-1 (Gebrauchsklassen GK0-GK5), -2 (chemical + constructional protection), DIN 4074-1, EN 350 (natural durability) | EN ISO 12944 (corrosivity categories C1-C5 + immersion), EN ISO 1461 (hot-dip galvanizing), EN 10346 (continuously coated strip) | |
| Execution | DIN 18334 (ATV timber works), trade rules of the roof/carpentry trades | EN 1090-1/-2 (EXC 0-4), DIN 18335 (ATV steel works) | |
| Fire classification | DIN 4102 / DIN EN 13501-2 (F30-F180 ↔ R/E/I) | same |
⚠ VERIFY editions and NA currency per Bundesland/country before citing.Fastener approvals are time-limited: a handbook may list a punched-plate/angleconnector approval (abZ) whose validity expired years earlier — never carry anapproval number from a table into a project without checking its current status.
1.2 Partial factors and combinations (starting point, German NA of the digest edition)
Actions (persistent/transient, STR): γ_G unfavourable 1.35 / favourable 1.00; γ_Q 1.50. ψ0/ψ1/ψ2 for buildings: living/office A,B 0.7/0.5/0.3; assembly C 0.7/0.7/0.6; retail D 0.7/0.7/0.6; storage E 1.0/0.9/0.8; roof (non-accessible) H 0/0/0; snow ≤ 1000 m NN 0.5/0.2/0.0; wind 0.6/0.2/0.0.
Timber resistances: γ_M = 1.3 members (solid, BSH, and most wood-based panels incl. CLT/Balkenschichtholz); γ_M = 1.1 dowel-type connections by the simplified verification; 1.3 exact yield-theory check; 1.3 ring/ shear-plate connectors (§5.7 — different failure mode from dowel bending, do not reuse 1.1); steel connector parts in tension/shear 1.3; nail-plate (Nagelplatte) plate check 1.25.
Fire design — CORRECTED, the earlier "γ_M,fi table" was a mislabelling, not a real contradiction with the worked example (Neuhaus, Ingenieurholzbau, 4th ed. 2017, p.155/159-160/174-176, Tab. 4.12, EN 1995-1-2 Tab. 2.1 + DIN EN 1995-1-2/NA NDP to 2.3(2) Note 1): the differentiated table (solid 1.25, glulam 1.15, panels 1.15, LVL 1.1 — resolves the "1.0 (1.1 in the digest)" ambiguity in favour of 1.1, shear connections timber-side 1.15 / outer-steel-plate 1.05, pull-out 1.05) is actually k_fi, the coefficient converting the 5 %-characteristic value to the 20 %-quantile fire strength: f_20 = k_fi·f_k. γ_M,fi itself is 1.0, uniformly, for ALL timber materials and connections — so the correct fire design equation is f_d,fi = k_mod,fi·(k_fi·f_k)/1.0, with k_fi in the numerator, not a γ_M in the denominator. The worked fire example (which applies 1.0 to member bending) was already right; only the general statement needed relabelling and moving k_fi to the correct place in the equation.
Steel resistances: γ_M0 = 1.0 (cross-section), γ_M1 = 1.1 (stability: buckling, LTB, patch loading per 1993-1-5), γ_M2 = 1.25 (net sections, bolt bearing, welds) — as used in the worked example chains of this file.
⚠ VERIFY NA state (γ_M1 was 1.0 for section checks in the example chain fortension M-N interaction; treat 1.0/1.1 split as edition-dependent).
Timber combination rule (the classic trap): design value X_d = X_k · k_mod / γ_M sits in the denominator, so the governing load case is the one with maximum F_d / k_mod, not maximum F_d. Example (solid/BSH, CL1): 1.35G + 1.5S → F_d = 12.4 kN/m over k_mod 0.6 → 20.7; 1.35G + 1.5W → k_mod 1.0. Always run the division for every combination (permanent 0.6, snow short 0.9, wind NA 1.0, medium 0.8, very short 1.1).
Fire combination (both materials): γ_G = γ_Q = 1.0, variables at ψ1 (worked timber R30: 0.5); exceptional design situation.
Section 2: Framing-system taxonomy (generic)
2.1 Timber systems
This is the start of the file. Read the full SKILL.md on GitHub.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/timber-steel-design/SKILL.md
Popularity
- 7-day trend score
- 0
Not refreshed yet.
Extension points
pluginCustom plugin integration
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/felixkarevo/construction-skills/timber-steel-design)