mp-ai-20/mechanical-engineering-skills/acoustic-induced-vibration

Claude Code and agent skill by mp-ai-20/mechanical-engineering-skills

Trust tier 3
  • community
Source check pending

Checking that the SKILL.md file is still in the repository.

Acoustic-induced vibration (AIV) in piping — Carucci-Mueller method, flow-induced noise, acoustic power, pipe wall response, branch connections, EI guidelines, NORSOK L-002.

Install

npx vskill@latest install mp-ai-20/mechanical-engineering-skills/acoustic-induced-vibration

SKILL.md

The same SKILL.md was published earlier as mp-ai-20/mechanical-engineering-skills/acoustic-induced-vibration.

Acoustic-Induced Vibration (AIV) in Piping — Complete Skill

Background and Problem

AIV: high-frequency sound generated by high-velocity gas flow through valves/orifices drives pipe wall vibration → fatigue cracking at stress concentrations (branch connections, fittings, instrumentation) Typical frequency range: 500 Hz – 2 kHz (where pipe wall is excited by internal acoustic field) At-risk locations: branch connections < 50 mm diameter; small-bore fittings; thermowell nozzles; vents

Acoustic Power Generation (Carucci-Mueller Method)

Acoustic power generated by control valve/orifice: W_a = W_flow × η_a [W]

Acoustic efficiency η_a: For pressure ratios P₁/P₂ (upstream/downstream): η_a = 10^(-4) × Δh_s² / (4 × c₄ × R²) [simplified; use lookup chart for exact value]

Carucci-Mueller acoustic power level (L_w): L_w = 10 log₁₀(W_a / 10⁻¹²) [dB re 1 pW]

Empirical Carucci-Mueller formula: L_w [dB] = 10 log₁₀[m_dot × (ΔP/P₁)³ × (P₁ - P₂)²] + C C = constant depending on Mach number downstream of valve; typically C ≈ 126 for choked flow

Alternative (EI guidelines): L_w = 10 log₁₀(W_flow) + 10 log₁₀(η_a) + 120 W_flow = P₁ × Q_flow [W; Q_flow = volumetric flow rate at P₁ [m³/s]]

Acoustic efficiency (simplified by pressure ratio): P₁/P₂ < 1.5: η_a ≈ 10⁻⁵ (low efficiency) P₁/P₂ = 1.5–4.0: η_a ≈ 10⁻⁴ to 10⁻³ (moderate) P₁/P₂ > 4.0 (choked): η_a ≈ 10⁻³ to 10⁻² (high efficiency, high risk)

Pipe Wall Sound Pressure Level

Internal SPL (inside pipe): L_p = L_w - 10 log₁₀(π × D × L × α_pipe) + C_geometry [dB] D = pipe ID [m]; L = pipe section length [m]; α_pipe = acoustic absorption coefficient

Practical estimate (EI guidelines): L_p ≈ L_w - 5 to 10 dB (for fully developed plane wave at > 3D from valve)

Pipe Wall Response

Coincidence frequency: f_co = c_gas / (π × t_w × c_L) [Hz] t_w = wall thickness [m]; c_L = longitudinal wave speed in steel ≈ 5100 m/s; c_gas = sound speed in gas [m/s]

At coincidence: pipe wall radiates/receives maximum sound → maximum vibration

Ring frequency: f_ring = c_L / (π × D_mean) [Hz; D_mean = mean diameter] Steel pipe 6" (D = 168 mm): f_ring = 5100/(π × 0.168) ≈ 9.7 kHz

Pipe wall vibration level: v_rms = σ_rms / (ρ_steel × c_L) × (L_p correction) [mm/s] At-risk: if pipe wall velocity > 10 mm/s RMS → fatigue concern at connections

AIV Risk Assessment (EI Guidelines Method)

Energy Institute (EI) AIV Guideline — 2 step:

Step 1 — Acoustic power level: Calculate L_w [dB] from valve/orifice conditions

Step 2 — L_w vs. pipe size threshold:

Pipe OD [mm]L_w threshold [dB] for high risk
50145
100149
150152
200154
300157
400159
600162

If L_w > threshold → high AIV risk → requires mitigation or detailed analysis

Small-Bore Connections (SBC) Assessment

Most vulnerable: ≤ DN50 (2") branch connections welded to header Failure mode: fatigue crack at fillet weld toe; perpendicular to pipe axis

SBC vibration velocity limit: v_rms < 15 mm/s for standard fillet welds v_rms < 25 mm/s for full-penetration welds

Reinforcement options:

  • Stiffening gussets at branch
  • Full-encirclement collar/ring
  • Increase SBC natural frequency: add rigid support within 150 mm

Mitigation Measures

Source reduction:

  • Replace single-stage valve with multi-stage (reduces Δh_s/stage)
  • Add downstream diffuser/silencer plate
  • Limit pressure ratio across single valve: P₁/P₂ ≤ 3.0

Path control:

  • Increase wall thickness (reduce vibration amplitude)
  • Apply constrained damping treatment
  • Reroute small-bore connections to low-SPL zone (3+ pipe diameters from valve)

Receiver protection:

  • Full-penetration welds for all SBC connections
  • Eliminate threaded connections in high-AIV zones
  • Stiffen or remove unnecessary small-bore nipples

NORSOK L-002 Requirements

Screening criterion: Calculate L_w for all gas valves with ΔP > 0.5 bar If L_w > 155 dB → detailed analysis required

Design requirement: All SBC connections within 10D of high-L_w source: full-penetration welds + stiffening

Standards

StandardScope
EI GuidelinesAIV assessment methodology (Energy Institute, 2008)
NORSOK L-002Piping design; AIV screening requirement
API RP 521Pressure-relieving systems (also covers AIV from PRVs)
PIP PCTPA001Process acoustics design

Output

Provide: acoustic power level L_w [dB re 1 pW] at each valve/orifice, pressure ratio P₁/P₂, acoustic efficiency η_a, AIV risk classification (low/moderate/high per EI guidelines), coincidence frequency [Hz], small-bore connection assessment and velocity limit [mm/s], recommended mitigation (multi-stage valve/silencer/wall thickness/SBC reinforcement), and applicable standard (EI AIV Guidelines, NORSOK L-002).

Security

  • Security scanPassed, 90 of 100Pattern checks on the skill's files.
  • Model reviewPassed

Quality evaluation

  • Task evaluationNot runNo evaluation yet. Run one in Skill Studio.

Source

Popularity

7-day trend score
0

Not refreshed yet.

Works with

Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.

  • Claude Code
  • Cursor
  • GitHub Copilot
  • Windsurf
  • Codex
  • Gemini CLI
  • Cline
  • Amp
  • Roo Code
  • Goose
  • Continue
  • Kilo Code
  • Junie
  • Trae
  • OpenHands
  • Qwen Code
  • AI Agent
  • Tabnine Chat
  • Sourcegraph Cody
  • Amazon Q
  • Firebase Genkit
  • Sweep
  • Devin
  • Phind
  • Mentat
  • Claude Desktop
  • Aider
  • GPT Pilot
  • Plandex
  • bolt.new
  • v0
  • Replit Agent
  • Anse
  • TypingMind
  • BetterChatGPT
  • LibreChat
  • Warp AI
  • Pieces
  • Fig AI
Embed badge
vskill VERIFIED badge
[![vskill VERIFIED](https://verified-skill.com/api/v1/skills/mp-ai-20/mechanical-engineering-skills/acoustic-induced-vibration/badge)](https://verified-skill.com/skills/mp-ai-20/mechanical-engineering-skills/acoustic-induced-vibration)

Something wrong with this skill or its page? Tell us.