pharmolix/openbiomed/single-cell-proteomics-data-processing
Claude Code and agent skill by pharmolix/openbiomed
- community
Checking that the SKILL.md file is still in the repository.
Install
npx vskill@latest install pharmolix/openbiomed/single-cell-proteomics-data-processingSKILL.md
The same SKILL.md was published earlier as pharmolix/openbiomed/single-cell-proteomics-data-processing.
Raw Mass Spectrometry Data Processing (pyOpenMS)
Load, inspect, centroid, and extract features from raw LC-MS/MS data files. This is Step 1 of the proteomics pipeline — all downstream peptide identification and quantification steps require centroided, quality-checked spectra as input.
What it does
- Loads raw or profile-mode spectra from mzML, mzXML, or vendor-converted files using pyOpenMS
- Inspects run-level QC metrics: total ion current (TIC), scan counts per MS level, m/z and RT ranges
- Converts profile-mode spectra to centroid mode using PeakPickerHiRes
- Extracts MS1 and MS2 spectra separately for downstream use
- Detects LC-MS features (isotope envelopes) using FeatureFinder for label-free quantification
- Extracts extracted ion chromatograms (EIC) for targeted m/z values
- Converts between mzML, mzXML, and featureXML formats
- Generates per-run QC plots (TIC, scan distribution, peak width)
Why this exists
If you ask a general AI to "process my mzML files for proteomics," it will:
- Not distinguish between profile-mode and centroid-mode spectra (critical difference for downstream tools)
- Use incorrect pyOpenMS API calls (the API changed significantly between versions 2.x and 3.x)
- Skip quality control checks that reveal injection failures, column issues, or contamination
- Not explain the difference between peak picking and feature detection, or when each is needed
- Produce centroided output without verifying peak width or mass accuracy
This skill encodes the correct methodological decisions:
- Checks MS level distribution before processing to confirm DDA vs. DIA acquisition mode
- Applies PeakPickerHiRes (correct algorithm) not PeakPickerIterative (for Orbitrap data)
- Separates MS1 feature detection (for LFQ) from MS2 centroiding (for database search)
- Generates TIC plots to visually confirm run quality before investing compute time in search
- Uses pyOpenMS 3.x API (
MSExperiment,MzMLFile) which differs from 2.x
Reference Methods
pyOpenMS is the Python interface to OpenMS (Röst et al., 2016), a C++ framework for computational mass spectrometry. It provides direct access to the full OpenMS algorithm library including peak picking, feature detection, alignment, and quantification.
PeakPickerHiRes: Gaussian-based centroiding algorithm optimized for high-resolution instruments (Orbitrap, Q-TOF). Fits a Gaussian to each isotope peak and reports the apex m/z and intensity. Requires profile-mode input.
FeatureFinderCentroided: Identifies LC-MS features by grouping isotope envelopes across consecutive MS1 scans. Outputs feature maps with m/z, RT, intensity, and charge state per feature. Used as input to label-free quantification.
File formats:
mzML: Open, XML-based vendor-neutral format. Use for all pipeline steps.mzXML: Older open format; convert to mzML with msconvert if needed.featureXML: OpenMS-native format for feature maps.pepXML/mzIdentML: Downstream peptide identification results formats.
Usage (Python — pyOpenMS)
Batch processing multiple runs
Example Output
Interpretation Guide
- MS2/MS1 ratio: A ratio of 5–20 is typical for DDA experiments. Ratio < 3 suggests the instrument was triggering few MS2 events (check intensity threshold settings); ratio > 30 is unusual
- Profile vs centroid: Profile data shows Gaussian peak shapes per m/z; centroid data shows single m/z values per peak. Database search tools (MSFragger, Comet) require centroid input
- TIC shape: A broad, smooth Gaussian-like TIC indicates a good LC gradient. Flat TIC at the start/end is normal (column equilibration). Sudden drops mid-gradient indicate injection failure or column clogging
- Feature count: 10,000–30,000 features per run is typical for a HeLa cell digest on Orbitrap. Fewer than 5,000 suggests poor digest efficiency, short gradient, or injection problems
- Charge state distribution: z=2 and z=3 should dominate (> 60% combined) for a typical tryptic digest. High z=1 fraction suggests incomplete digestion or non-tryptic peptides
- EIC tolerance: Use ± 5–10 ppm for Orbitrap data (e.g., ± 0.003 Da at m/z 600); use ± 50 ppm or ± 0.05 Da for Q-TOF data
Citation
If you use this skill in a publication, please cite:
- Röst, H.L. et al. (2016). OpenMS: a flexible open-source software platform for mass spectrometry data analysis. Nature Methods, 13(9), 741–748.
- Sturm, M. et al. (2008). OpenMS — an open-source software framework for mass spectrometry. BMC Bioinformatics, 9, 163.
Security
- Security scanPassed, 100 of 100Pattern checks on the skill's files.
- Model reviewNot runA model review is scheduled for the next rescan.
Quality evaluation
- Task evaluationNot runNo evaluation yet. Run one in Skill Studio.
Source
- SKILL.md in the repositoryCheckingskills/single-cell-proteomics-data-processing/SKILL.md
Popularity
- Repository stars
- 1,105
- Repository forks
- 132
- 7-day trend score
- 35
Stars and forks are for the whole GitHub repository, not this skill alone. Not refreshed yet.
Works with
Any agent vskill installs to: 56 targets in all. These 39 have a page on this site.
- Claude Code
- Cursor
- GitHub Copilot
- Windsurf
- Codex
- Gemini CLI
- Cline
- Amp
- Roo Code
- Goose
- Continue
- Kilo Code
- Junie
- Trae
- OpenHands
- Qwen Code
- AI Agent
- Tabnine Chat
- Sourcegraph Cody
- Amazon Q
- Firebase Genkit
- Sweep
- Devin
- Phind
- Mentat
- Claude Desktop
- Aider
- GPT Pilot
- Plandex
- bolt.new
- v0
- Replit Agent
- Anse
- TypingMind
- BetterChatGPT
- LibreChat
- Warp AI
- Pieces
- Fig AI
Embed badge
[](https://verified-skill.com/skills/pharmolix/openbiomed/single-cell-proteomics-data-processing)